Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com RPD-160 160W Dual Output Medical Type ¡¡E¡½ E ¡E ¡E ¡E E¡¡E ¡E ¡E ¡E series Features : Universal AC input / Full range Built-in active PFC function Protections: Short circuit / Overload / Over voltage / Over temperature 5"x3" compact size Free air convection for 100W and 150W with 20.5 CFM forced air Medical safety approved (MOPP level) With power good and fail signal output No load power consumption under 0.75W by PS-ON control (G model) Standby [email protected] with fan, @0.6A without fan (G model) 3 years warranty RPD G G: With 5Vsb & no load power consumption < 0.75 W Blank: Basic function (without 5Vsb) 160B SPECIFICATION MODEL RPD-160B OUTPUT NUMBER CH1 CH2 DC VOLTAGE 5V 24V RATED CURRENT (20.5CFM) 12A 3.6A CURRENT RANGE (convection) 1 ~ 6A 0.2 ~ 2.8A CURRENT RANGE (20.5CFM) 1 ~ 12A 0.2 ~ 3.6A RATED POWER (convection) Note.7 100.2W OUTPUT RATED POWER (20.5CFM) Note.8 150.4W RIPPLE & NOISE (max.) Note.2 80mVp-p 200mVp-p VOLTAGE ADJ. RANGE ¡Ó6.0% Ó¡ 1.0% Ó¡ 3.0% CH1: 5 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.5% ¡Ó Ó¡ 0.5% Ó¡ 1.5% LINE REGULATION LOAD REGULATION SETUP, RISE TIME 1800ms, 30ms/230VAC HOLD UP TIME (Typ.) 16ms/230VAC/115VAC at full load VOLTAGE RANGE INPUT Note.6 90 ~ 264VAC 3500ms, 30ms/115VAC at full load 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) EFFICIENCY (Typ.) PF>0.93/230VAC 84% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.7A/115VAC 0.9A/230VAC COLD START 35A/115VAC 70A/230VAC LEAKAGE CURRENT PF>0.98/115VAC at full load £g £g Note.9 Earth leakage current < 200 A/264VAC , Touch current < 100 A/264VAC OVERLOAD OVER VOLTAGE PROTECTION OVER TEMPERATURE 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover 105 (TSW1) detect on heatsink of power transistor ¢J ¢J(TSW2 ) detect on heatsink of power transistor 90 Protection type : (TSW1)Shut down o/p voltage, recovers automatically after temperature goes down Protection type : (TSW2)Shut down o/p voltage, re-power on to recover 5VSB : [email protected] without fan, 0.8A with fan 20.5CFM ; tolerance 2%, ripple : 50mVp-p(max.) 5V STANDBY (G model) PS-ON INPUT SIGNAL (G model) Power on: PS-ON = "Hi" or " > 2 ~ 5V" ; Power off: PS-ON = "Low" or " < 0 ~ 0.5V" PF>1ms POWER GOOD / POWER FAIL 500ms>PG>10ms -20 ~ +70 (Refer to "Derating Curve") WORKING TEMP. ¡Ó FUNCTION ¢J WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION EMC IMMUNITY MTBF OTHERS NOTE DIMENSION PACKING 20 ~ 90% RH non-condensing ¢J, 10 ~ 95% RH ¡Ó0.03%/¢J (0 ~ 50¢J) -40 ~ +85 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes ANSI/AAMI ES60601-1, TUV EN60601-1 approved I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC ¢J I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A ¢J) 196.3K hrs min. MIL-HDBK-217F (25 127*76.2*34.6mm (L*W*H) 0.33Kg; 36pcs/12.9Kg/0.79CUFT ¢J 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. HS1,HS2 & HS3 can not be shorted. 6. Derating may be needed under low input voltages. Please check the derating curve for more details. 7. The rated power includes 5Vsb @ 0.6A. 8. The rated power includes 5Vsb @ 0.8A. 9. Touch current was measured from primary input to DC output. Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com RPD-160 160W Dual Output Medical Type series Mechanical Specification Unit:mm FAN AC Input Connector (CN1) : JST B3P-VH or equivalent 5cm Pin No. 1 2 3 5 20.5CFM min. SVR1 66.2 Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent DC Output Connector (CN2) : JST B8P-VH or equivalent 1 2 76.2 Mating Housing CN3 HS1 1 2 3 HS3 FS2 Pin No. 1,2,3,4 5,6 7 8 1 2 3 4 5 6 7 8 HS2 FS1 CN1 Assignment AC/L No Pin AC/N CN2 CN901 LED CN901 45 117 £r3. Assignment COM CH1 CH2 NC Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Power Good Connector(CN3):JST B2B-XH or equivalent Pin No. Status Mating Housing Terminal 1 2 PG GND JST XHP or equivalent JST SXH-001T-P0.6 or equivalent 1234 5 5VSB Connector(CN901) : JST B-XH or equivalent 127 Pin No. 1 2,4 3 PS/ON 34.6 5mA(max.) GND Assignment Mating Housing Terminal JST XHP or equivalent JST SXH-001T or equivalent PS/ON GND 5VSB 3 max. HS1,HS2,HS3 can not be shorted Block Diagram POWER SWITCHING PWM CONTROL RECTIFIERS & PFC EMI FILTER I/P POWER SWITCHING +5VSB DETECTION CIRCUIT RECTIFIERS & FILTER RECTIFIERS & FILTER RECTIFIERS & FILTER fosc :100KHz +5VSB +V2 +V1 COM PG PG DETECTION CIRCUIT FG CONTROL O.L.P. O.V.P. PS/ON CONTROL Derating Curve PS/ON Output Derating VS Input Voltage 100 100 With FAN 90 80 80 70 Without FAN LOAD (%) LOAD (%) 60 40 20 -20 0 10 20 30 40 50 ¢J AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RPD-160-SPEC 2012-09-03