MEANWELL SKA20_12

SKA20
20W DC-DC Regulated Single Output Converter
series
Features :
2" 1" compact size
2:1 wide input range
High efficiency up to 89.5%
1500VDC I/O isolation
Built-in remote ON/OFF control
Built-in trimming output
Built-in EMI filter
Protections: Short circuit / Overload / Input and Output Over voltage
Cooling by free air convection
Six-sided shield metal case
100% burn-in test
Low cost / High reliability
Approvals: FCC / CE
2 years warranty
SPECIFICATION
ORDER NO.
SKA20A-05 SKA20B-05 SKA20C-05 SKA20A-12 SKA20B-12 SKA20C-12 SKA20A-15 SKA20B-15 SKA20C-15
DC VOLTAGE
5V
12V
15V
CURRENT RANGE
400 ~ 4000mA
166 ~ 1666mA
133 ~ 1333mA
RATED POWER
20W
60mVp-p
60mVp-p
220uF
-20 ~ +10%
100uF
-20 ~ +10%
RIPPLE & NOISE (max.) Note.2 50mVp-p
OUTPUT
LINE REGULATION
Note.3
0.2%
LOAD REGULATION
Note.4
0.5%
2.0%
VOLTAGE ACCURACY
300KHz typ.
SWITCHING FREQUENCY
EXTERNAL CAPACITANCE LOAD (max.) 1000uF
EXTERNAL TRIM Adj. RANGE(Typ.) 10%
VOLTAGE RANGE
A: 9 ~ 18VDC B: 18 ~ 36VDC C: 36 ~ 75VDC
88%
88.5%
87.5%
88%
88.5%
87.5%
89%
89.5%
88%
Full load 1910mA
970mA
490mA
1910mA
970mA
500mA
1870mA
950mA
490mA
No load
55mA
40mA
35mA
25mA
15mA
35mA
25mA
15mA
EFFICIENCY (Typ.)
DC CURRENT
INPUT
80mA
Pi network
Power ON : R.C ~ -Vin > 2.5VDC or open circuit ; Power OFF : R.C ~ -Vin < 0.5VDC or short
FILTER
REMOTE CONTROL
Fuse recommended
PROTECTION
110% ~ 180% rated output power
OVER CURRENT
PROTECTION
(Note. 5)
SHORT CIRCUIT
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
All output equipped with short circuit
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Input(Typ.) A: >20 ~ 23VDC
B: >40 ~ 43VDC
C: >80 ~ 82VDC input voltage
Output
Protection type : Shut down o/p voltage, recovers automatically after fault condition is removed
-40 ~ +85
WORKING TEMP.
WORKING HUMIDITY
(Refer to "Derating Curve")
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -55 ~ +125 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
TEMP. COEFFICIENT
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
VIBRATION
I/P-O/P:1.5KVDC
WITHSTAND VOLTAGE
I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH
SAFETY & ISOLATION RESISTANCE
EMC EMISSION
EMC
Compliance to EN55022 Class A, FCC part 15 Class A
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A
700Khrs min. MIL-HDBK-217F(25
50.8*25.4*11.2 mm or 2"*1"*0.44" inch (L*W*H)
WEIGHT
31.2g
20.4[0.80]
5.8
[0.23]
Unit:mm(inch)
1
5
4
SIDE
VIEW
+Vin
4
Trim
2
-Vin
5
-Vout
3
+Vout
6
R.C
-Vin
+Vout
-Vout
0.10mm
50
3
5
20K
LOAD
VR
-40
VR
1
25.4[1.00]
100
External Output Trimming
2
3
10.2
[0.40]
Pin No. Output
1
NOTE: Pin Size is Tolerance 1.0
20.32[0.80]
2
BOTTOM
VIEW
Pin No. Output
15.24[0.60]
50.8[2.00]
7.62 5.08
[0.30] [0.20]
6
Derating Curve
Pin Configuration
Mechanical Specification
NOTE
)
MTBF
DIMENSION
LOAD (%)
OTHERS
11.2[0.44]
+Vin
Trim
25
50 75
Ta (
4
UP
0
DOWN
85
100
)
TRIMPOT
1.All parameters are specified at normal input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load.
5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
File Name:SKA20-SPEC 2012-01-07