TN-3000 3000W True Sine Wave DC-AC Inverter with Solar Charger series Features : True sine wave output (THD<3%) High surge power up to 6000W U.P.S. mode and energy saving mode (selectable) High efficiency up to 92% Power ON-OFF switch Standby saving mode can be selectable Front panel indicator for operation status Thermostatically controlled cooling fan Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input polarity reverse / Overload / AC circuit breaker Application : Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. Built-in solar / AC charger Optional monitoring software and connection cable (MW order No.: DS-TN-1500) 3 years warranty E13 SPECIFICATION MODEL TN-3000-112 TN-3000-124 TN-3000-148 TN-3000-212 TN-3000-224 TN-3000-248 3000W RATED POWER (Typ.) MAXIMUM OUTPUT POWER (Typ.) 3450W for 180 sec. / 4500W for 10 sec. / surge power 6000W for 30 cycles Factory setting set at 110VAC AC VOLTAGE OUTPUT 200 / 220 / 230 / 240VAC selectable by setting button S.W FREQUENCY 60 0.1Hz 50 0.1Hz WAVEFORM True sine wave (THD<3%) at rated input voltage 50/60Hz selectable by setting button S.W TRANSFER TIME (Typ.) 10ms inverter SAVING MODE (Typ.) Load by pass 5W will be changed to standby mode FRONT PANEL INDICATOR Battery voltage level, output load level, saving mode, fault and operation status BAT. VOLTAGE 12V VOLTAGE RANGE (Typ.) Note.3,6 10.5 ~ 15VDC DC CURRENT (Typ.) Note.4 300A 24V 48V 12V 24V 48V 21 ~ 30VDC 150A 42 ~ 60VDC 75A 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 300A 150A 75A 91% 89% 91% 92% 20A*6 45V 40A*12 11.3V 40A*6 22.5V 20A*6 45V 42V 10.5V 21V 42V NO LOAD DISSIPATION (Typ.) 10W @ standby saving mode OFF MODE CURRENT DRAW (Typ.) 1mA EFFICIENCY (Typ.) Note.1 88% 90% Open & sealed lead acid battery BATTERY TYPES FUSE 40A*12 40A*6 BATTERY BAT. LOW ALARM 22.5V Note.6 11.3V INPUT 21V PROTECTION BAT. LOW SHUTDOWN Note.6 10.5V By internal fuse open REVERSE POLARITY 90 OVER TEMPERATURE SAFETY & EMC WORKING HUMIDITY 85 5 85 5 75 5 75 5 Protection type : Shut down o/p voltage, re-power on to recover AC output: 20A, AC receptacle: 15A AC output: 40A, AC receptacle:15A Optional (Only type F) Note.2 0 ~ +40 @ 100% load ; 60 @ 50% load 20% ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY VIBRATION -30 ~ +70 None o / -22 ~ +158 F, 10 ~ 95% RH SAFETY STANDARDS 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes UL458 (only for "GFCI" receptacle-Type F ) None LVD WITHSTAND VOLTAGE None Bat I/P - AC I/P:3.0KVAC ISOLATION RESISTANCE Bat I/P - AC O/P, Bat I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25 / 70% RH Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark 25A AC CHARGER CHARGE CURRENT (Typ.) SOLAR PANEL MAX OPEN CIRCUIT VOLTAGE 25V NOTE 80 Protection type : Shut down o/p voltage, re-power on to recover Bat I/P - AC O/P:3.0KVAC EMI CONDUCTION&RADIATION Compliance to FCC class A None EMS IMMUNITY OTHERS 5 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. CIRCUIT BREAKER GFCI PROCTECTION WORKING TEMP. 5 Protection type : Shut down o/p voltage, re-power on to recover OUTPUT SHORT OUTPUT PROTECTION OVER LOAD (Typ.) ENVIRONMENT 50/60Hz selectable by setting button S.W 3% AC REGULATION (Typ.) INPUT Factory setting set at 230VAC 100 / 110 / 115 / 120VAC selectable by setting button S.W CHARGE VOLTAGE Note.6 14.3V EN60950-1 AC O/P - FG:1.5KVAC Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204 12A 6A 25A 12A 6A 28.5V 57V 14.3V 28.5V 57V 45V 75V 25V 45V 75V SHORT CIRCUIT CURRENT (max.) 30A RJ11 -RS232 (Option) CONTROL WIRING DIMENSION PACKING 466.8*283.5*100mm (L*W*H) 12.9Kg; 1pcs/14Kg/1.98CUFT 1.Efficiency is tested by 2100W, linear load at 13V, 26V, 52V input voltage. 2.Output derating capacity referenced by curve 1. 3.Output derating capacity referenced by curve 2. 4.DC current is tested by 3000W, linear load at 12V, 24V, 48V input voltage. 5.All parameters not specified above are measured at rated load, 25 of ambient temperature. 6.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248 2V File Name:TN-3000-SPEC 2011-02-09 3000W True Sine Wave DC-AC Inverter with Solar Charger TN-3000 series Instructions for TN-3000 monitoring software 1. Installation of TN-3000 unit and PC 9 8 7 6 1 6 5 4 3 2 1 Phone Jack RJ11 DB9 FEMALE RJ11 PIN NO. DB9 PIN NO. 2 3 4 3 5 2 Figure 1 2. Explanation of Monitoring Manu 2.1 Main Page Inverter TN V1.38 Setting Statistics R.C. Power off Pause 2 3 4 1 Exit Solar Charge INVERTER 100 AC Charge 100 0 Battery 5 0 Loading O/P Voltage 230 V O/P Frequency 50.0 Hz Battery Voltage 13.5 V Internal Temperature 10.0 AC In By pass Utility Voltage 0.0 V TN-3000-212 6 Start Date 2010/01/01 03:13:33 PM Reset Date 2010/01/01 01:40:56 PM Power on Remote off Battery low Battery used up Stand by saving mode Abnormal Shutdown Figure 2 1. Setting: Adjustment for output voltage, charging related voltage, frequency, and operation mode. Please refer to Figure 3 for details. 2. Statistics: Calculate for the percentage of operating period for each operation mode. Please refer to Figure 4 for details. 3. R.C. Power off: Power can be turned ON or OFF at the remote location. 4. Pause: Stop refreshing the page of monitoring software. 5. Status of unit: Indicating current operating status of TN-3000. 6. Signals that display current condition of the unit. File Name:TN-3000-SPEC 2011-02-09 3000W True Sine Wave DC-AC Inverter with Solar Charger TN-3000 series 2.2 Setting Page Inverter Setting File Name D:\TN_110RR\20100101\REV\TN_110RR\TNF\TN_3K0_512.TNF Model name TN-3000-212 Manufacture MeanWell Series Number LOC-1234567890 Revision REV:1.38 Date Of Manu. 01/01/2010 I/O Type 212 Voltage 230 V Equalization Volt. 14.3 V 13.6 ~ 15.0V Floating Volt. 13.3 V 13.0 ~ 13.5V Alarm Volt. 11.3 V 11.1 ~ 11.5V Shutdown Volt. 10.5 V 10.0 ~ 11.0V 1 Frequency Stand-by saving mode UPS mode Energy saving mode 50 Hz Off On On On Comm Ports Bauds Rate 9600 1 Read Write Lead 2 3 4 Exit Read OK!! Figure 3 1. User can adjust the settings based on the characteristics of batteries been used: Equalization Voltage, Floating Voltage, Alarm Voltage, and Shut-down Voltage. UPS Mode / Energy Saving Mode selection and AC output voltage and frequency can also be set in this page. 2. Read: Read current settings of the unit. 3. Write: Write the revised setting into the unit. 4. Load: Load in factory default settings. 2.3 Statistic Page Inverter Setting Start Date 2010/01/01 03:13:33 PM Inverter time rate 91.2 % Bypass time rate 0.0 % Shut Down rate 8.8 % Solar time rate 0.0 % Loading average 24.7 % Start Date 2010/01/01 01:40:56 PM Inverter time rate 31.9 % Bypass time rate 0.0 % Shut Down rate 68.1 % Solar time rate 0.0 % Loading average 63.7 % RESET Exit Figure 4 1. Start Date: Date that installing the monitoring software. 2. Reset Date: Date that resetting the statistics. The Start Date will not be influenced by resetting the statistics or turning off the unit. 3 .Inverter time rate: Operating period of "Inverter Mode" represents how many percent of the whole operating period. 4. Bypass time rate: Operating period of "Bypass Mode" (energy provides directly by the utility) represents how many percent of the whole operating period. 5. Shut down rate: Percentage of time period that the unit is under the condition of shut down. * Inverter time rate + Bypass time rate + Shut down rate = 100% 6. Solar time rate: Percentage of time period that the solar charger is functioning after turning on the TN-3000 unit. 7. Loading average: Average loading after turning on the TN-3000 unit. File Name:TN-3000-SPEC 2011-02-09 TN-3000 3000W True Sine Wave DC-AC Inverter with Solar Charger TN 3000 112 A True sine wave inverter +AC charger and solar charger A :TYPE A OUTLET B :TYPE B OUTLET C :TYPE C OUTLET D :TYPE D OUTLET E :TYPE E OUTLET F :TYPE F OUTLET 12:12VDC Bat. Voltage: 24:24VDC 48:48VDC Output: O/P Wattage:3000W series 1:110VAC 2:230VAC AC Output Receptacle (optional) Receptacle type TYPE-A TYPE-B TYPE-C TYPE-D TYPE-E TYPE-F USA EUROPE AUSTRALIA U.K JAPAN GFCI Country E13 Certificate E13 E13 (Expect for 48V input) Derating Curve Mechanical Specification Unit:mm 161.84 122.44 100 LOAD (%) POS 100 31.6 80 NEG Reverse Polarity Will Damage The Unit. 29 60 40 20 129.63 - 46 Air flow direction 0 + + + 10 20 30 40 50 60 70 AMBIENT TEMPERATURE ( ) CURVE 1 Air flow direction 100 LOAD (%) 90.3 80 7 7.5 60 40 20 10.5VDC 11.5VDC 15VDC (HORIZONTAL) AC Receptacle 466.8 286.2 BATTERY INPUT VOLTAGE (V) CURVE 2 SOLAR CHARGE ON AC CHARGE OFF 100 r R Ci s t o R e Bat Low AC IN BY PASS Saving (For Receptacle) (For AC Output) Chassis Ground Setting 0 t e 100 On 0 se r Ci t se t o e e s er Pr Pr er s s LOAD BATTERY INVERTER i t Br e ak cu i t Br e ak cu Cat.No.(1GG1HS-212) Wire Range(10-4 AWG Str Cu Soldered Wires) Torque (17.7-26.5 in lb) 13 Remote port AC INTPUT AC OUTPUT 31.29 Type-A AC INPUT L N AC OUTPUT L Note: When the load current is >15A, must use output terminal connection which can be found inside the AC output panel of the inverter. FG N AC Receptacle SOLAR CHARGE ON AC CHARGE OFF 100 r Ci t se e LOAD 100 Setting On 0 t 0 Bat Low se r Ci 12 34 R s e e 283.5 t o er Pr s s t o R e AC IN BY PASS Saving (For Receptacle) (For AC Output) Chassis Ground Cat.No.(1GG1HS-212) Wire Range(10-4 AWG Str Cu Soldered Wires) Torque (17.7-26.5 in lb) Remote port 13 273 Pr er s BATTERY INVERTER i t Br e ak cu i t Br e ak cu AC INTPUT AC OUTPUT 31.29 Type-B File Name:TN-3000-SPEC 2011-02-09