MEANWELL TN

TN-1500
1500W True Sine Wave DC-AC Inverter with Solar Charger
series
Features :
True sine wave output (THD<3%)
High surge power up to 3000W
U.P.S. mode and energy saving mode (selectable)
High efficiency up to 91%
Power ON-OFF switch
Standby saving mode can be selectable
Front panel indicator for operation status
Thermostatically controlled cooling fan
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input polarity reverse / Overload / AC circuit breaker
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
Built-in solar / AC charger
Optional monitoring software
E13
3 years warranty
SPECIFICATION
MODEL
TN-1500-124
TN-1500-112
TN-1500-148
TN-1500-212
TN-1500-224
TN-1500-248
1500W
RATED POWER (Typ.)
MAXIMUM OUTPUT POWER (Typ.) 1725W for 180 sec. / 2250W for 10 sec. / surge power 3000W for 30 cycles
Factory setting set at 110VAC
Factory setting set at 230VAC
100 / 110 / 115 / 120VAC selectable by setting button S.W
200 / 220 / 230 / 240VAC selectable by setting button S.W
FREQUENCY
60 0.1Hz
50 0.1%Hz
WAVEFORM
True sine wave (THD<3%) at rated input voltage
AC VOLTAGE
OUTPUT
50/60Hz selectable by setting button S.W
3.0%
AC REGULATION (Typ.)
TRANSFER TIME (Typ.)
10ms inverter
SAVING MODE (Typ.)
Default disabled. Load
FRONT PANEL INDICATOR
Battery voltage level, output load level, saving mode, fault and operation status
BAT. VOLTAGE
by pass
12V
VOLTAGE RANGE (Typ.)Note.1 10.5 ~ 15VDC
DC CURRENT (Typ.)
INPUT
Note.5 150A
37.5A
90%
88%
90%
91%
30A*3
22.5 4%
30A*2
45 4%
40A*5
11.3 4%
30A*3
22.5 4%
30A*2
45 4%
10.5 4%
21 4%
42 4%
10.5 4%
21 4%
42 4%
68
68
5
82
5
96
5
5
5
68
5
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
10A
20A
Optional (Only type F)
Note.3 0 ~ +40 @ 100% load ; 60 @ 50% load
20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
VIBRATION
LVD
WITHSTAND VOLTAGE
EMC EMISSION
-30 ~ +70
None
/ -22 ~ +158oF, 10 ~ 95% RH
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
UL458 (only for "GFCI" receptacle-Type F ) None
None
Bat I/P - AC I/P:3.0KVAC
Bat I/P - AC O/P:3.0KVAC
Compliance to FCC class A
None
EN60950-1
AC O/P - FG:1.5KVAC
Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
Compliance to EN61000-4-2,3,4,5,6,8,11
EMC IMMUNITY
CHARGE CURRENT (Typ.)
5.5A
2.7A
1.35A
5.5A
2.7A
CHARGE VOLTAGE
14.3V 4%
28.5V 4%
57V 4%
14.3V 4%
28.5V 4%
57V 4%
45V
75V
25V
45V
75V
57V 4%
14.3V 4%
28.5V 4%
57V 4%
MAX OPEN CIRCUIT VOLTAGE 25V
NOTE
75A
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
SAFETY STANDARDS
OTHERS
42 ~ 60VDC
150A
Protection type : Shut down o/p voltage, re-power on to recover ; by internal RTH3 detect on heatsink of power transistor
CIRCUIT BREAKER
SOLAR
CHARGER
48V
21 ~ 30VDC
40A*5
11.3 4%
82
OUTPUT SHORT
OUTPUT
PROTECTION OVER LOAD (Typ.)
AC
CHARGER
24V
10.5 ~ 15VDC
By internal fuse open
OVER TEMPERATURE
SAFETY &
EMC
12V
42 ~ 60VDC
37.5A
89%
Open & sealed Lead Acid
FUSE
BATTERY BAT. LOW ALARM
INPUT
PROTECTION BAT. LOW SHUTDOWN
REVERSE POLARITY
WORKING HUMIDITY
48V
21 ~ 30VDC
75A
Note.2 87%
BATTERY TYPES
ENVIRONMENT
24V
1mA
OFF MODE CURRENT DRAW
GFCI PROCTECTION
WORKING TEMP.
5W will be changed to standby mode
18W @ standby saving mode
NO LOAD DISSIPATION
EFFICIENCY (Typ.)
50/60Hz selectable by setting button S.W
CHARGE VOLTAGE
CONTROL WIRING
30A
28.5V 4%
14.3V 4%
RJ11 -RS232 (Option)
DIMENSION
PACKING
420*220*88mm (L*W*H)
6.85Kg; 2pcs/14.7Kg/1.61CUFT
CHARGE CURRENT (max.)
1.35A
1.Output derating capacity referenced by curve 1.
2.Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage.
3.Output derating capacity referenced by curve 2.
4.All parameters not specified above are measured at rated load, 25 of ambient temperature.
5.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage.
File Name:TN-1500-SPEC 2011-05-24
1500W True Sine Wave DC-AC Inverter with Solar Charger
TN-1500
series
Instructions for TN-1500 monitoring software
1. Installation of TN-1500 unit and PC
9
8
7
6
1
6
5
4
3
2
1
Phone Jack
RJ11
DB9 FEMALE
RJ11
PIN NO.
DB9
PIN NO.
2
3
4
3
5
2
Figure 1
2. Explanation of Monitoring Manu
2.1 Main Page
Inverter TN V.1.1
Setting
Statistics
R.C. Power off
Pause
2
3
4
1
Exit
Solar Charge
INVERTER
100
AC Charge
100
0
Battery
5
0
Loading
O/P Voltage 110 V
O/P Frequency 60.0 Hz
Battery Voltage 54.1 V
Internal Temperature 10.0
AC In
By pass
Utility Voltage 0.0 V
TN-1500-143
6
Start Date 2007/12/07 03:13:33 PM
Reset Date 2007/12/21 01:40:56 PM
Power on
Remote off
Battery low
Battery used up
Stand by saving mode
Abnormal Shutdown
Figure 2
1. Setting: Adjustment for output voltage, charging related voltage, frequency, and operation mode. Please refer to Figure 3 for details.
2. Statistics: Calculate for the percentage of operating period for each operation mode. Please refer to Figure 4 for details.
3. R.C. Power off: Power can be turned ON or OFF at the remote location.
4. Pause: Stop refreshing the page of monitoring software.
5. Status of unit: Indicating current operating status of TN-1500.
6. Signals that display current condition of the unit.
File Name:TN-1500-SPEC 2011-05-24
1500W True Sine Wave DC-AC Inverter with Solar Charger
TN-1500
series
2.2 Setting Page
Inverter Setting
File Name D:\TN_110RR\20071205\REV\TN_110RR\TNF\TN_1K5_512.TNF
Model name TN-1500-212
Manufacture MeanWell
Series Number
LOC-1234567890
Revision REV:1.10
Date Of Manu.
06/23/2007
I/O Type
212
Voltage
230
V
Equalization Volt.
14.3
V
13.5 ~ 15.0V
Floating Volt.
13.3
V
13.0 ~ 13.5V
Alarm Volt.
11.3
V
11.0 ~ 11.5V
Shutdown Volt.
10.5
V
10.0 ~ 11.0V
1
Frequency
Stand-by saving mode
UPS mode
Energy saving mode
50
Hz
Off
On
On
On
Comm Ports
Bauds Rate 9600
1
Read
Write
Lead
2
3
4
Exit
Read OK!!
Figure 3
1. User can adjust the settings based on the characteristics of batteries been used: Equalization Voltage, Floating Voltage, Alarm Voltage,
and Shut-down Voltage. UPS Mode / Energy Saving Mode selection and AC output voltage and frequency can also be set in this page.
2. Read: Read current settings of the unit.
3. Write: Write the revised setting into the unit.
4. Load: Load in factory default settings.
2.3 Statistic Page
Inverter Setting
Start Date 2007/12/07 03:13:33 PM
Inverter time rate
91.2 %
Bypass time rate
0.0 %
Shut Down rate
8.8 %
Solar time rate
0.0 %
Loading average
24.7 %
Start Date 2007/12/21 01:40:56 PM
Inverter time rate
31.9 %
Bypass time rate
0.0 %
Shut Down rate
68.1 %
Solar time rate
0.0 %
Loading average
63.7 %
RESET
Exit
Figure 4
1. Start Date: Date that installing the monitoring software.
2. Reset Date: Date that resetting the statistics. The Start Date will not be influenced by resetting the statistics or turning off the unit.
3 .Inverter time rate: Operating period of "Inverter Mode" represents how many percent of the whole operating period.
4. Bypass time rate: Operating period of "Bypass Mode" (energy provides directly by the utility) represents how many percent of the whole
operating period.
5. Shut down rate: Percentage of time period that the unit is under the condition of shut down.
* Inverter time rate + Bypass time rate + Shut down rate = 100%
6. Solar time rate: Percentage of time period that the solar charger is functioning after turning on the TN-1500 unit.
7. Loading average: Average loading after turning on the TN-1500 unit.
File Name:TN-1500-SPEC 2011-05-24
TN-1500
1500W True Sine Wave DC-AC Inverter with Solar Charger
TN
1500
112 A
True sine wave inverter
+AC charger and solar charger
A :TYPE A OUTLET
B :TYPE B OUTLET
C :TYPE C OUTLET
D :TYPE D OUTLET
E :TYPE E OUTLET
F :TYPE F OUTLET
12:12VDC
Bat. Voltage: 24:24VDC
48:48VDC
Output:
O/P Wattage:1500W
series
1:110VAC
2:230VAC
AC Output Receptacles (optional)
Receptacle type
TYPE-A
TYPE-B
TYPE-C
TYPE-D
TYPE-E
TYPE-F
USA
EUROPE
AUSTRALIA
U.K
JAPAN
GFCI
Country
E13
Certificate
E13
E13
(Expect for 48V input)
Derating Curve
Mechanical Specification
Unit:mm
100
88
LOAD (%)
Cat.No.(1GG1HS-212)
Wire Range(10-4 AWG Str
Cu Soldered Wires)
Torque (17.7-26.5 in lb)
NEG
Chassis
Ground
POS
Reverse Polarity
Will Damage The
Unit.
60
40
20
Solar Input
(30A max)
AC INPUT
20
80
44.25
11.05
22
DC
INPUT
47
0
-
20
30
40
50
60
70
AMBIENT TEMPERATURE ( )
CURVE 1
48
Air flow
direction
12.1
10
+
+
+
100
LOAD (%)
108.4
80
60
40
20
10
7
10.5VDC
21VDC
42VDC
11.5VDC
23VDC
46VDC
15VDC
30VDC
60VDC
(HORIZONTAL)
BATTERY INPUT VOLTAGE (V)
CURVE 2
AC OUTPUT
203.2
420
SOLAR CHARGE
ON
AC CHARGE
BATTERY
OFF
Setting
LOAD
100
100
INVERTER
On
it Br e
0
er
Ci
cu
AC IN
BY PASS
Saving
se
t
es
Pr
s
Bat Low
ak
r
0
to
R
e
Remote
port
Type-A
AC OUTPUT
SOLAR CHARGE
ON
AC CHARGE
BATTERY
OFF
100
Setting
LOAD
100
INVERTER
On
it Br e
0
Ci
er
es
Pr
s
Bat Low
ak
r
0
cu
AC IN
BY PASS
Saving
se
t
27.45
57.75
36.25
15.6
to
R
e
Remote
port
207
220
Type-B
File Name:TN-1500-SPEC 2011-05-24