SUU180 SERIES 180W U-bracket Switching Power Supplies For I.T.E. Description: The SUU180 series of compact, open frame constructed, AC/DC switching mode power supplies provide 180 Watts of continuous output power. They are suited for use in based systems, portable equipments and many other applications. All models meet FCC Part15 class B and CISPR-22 class B emission Limits and are designed to comply with UL/c-UL(UL 60950-1) ,TUV/Bauart(EN 60950-1) and new CE requirements. All units are 100% burned in and tested. Features: Wide Input Voltage 100 to 240 VAC,47 to 63 Hz Internal EMI filter Single Output Input connector mates with Molex housing 09-50-3031 and Molex 2478 series crimp terminal Output connector mates with Molex housing09-50-3081 and Molex 2478 series crimp terminal Output Voltage Available 12,24,48 VDC Input Surge Current and Over Load protection Over Voltage Protection (Crowbar Design) Active Power Factor Correction Class I Synchronous Rectification 2 year warranty Electrical Characteristics: Sym. Parameter Vin fin Safety Approvals : Test Conditions Operating Voltage Input Voltage CB BAUART GEPRUFT TYPE APPROVED Input Frequency Min. Typ. Max. Unit 100 240 VAC 47 63 Hz PF Power Factor Correction Io=Full load, Vin=100~240VAC Po Output Power Range Vin=100 to 240 VAC Vo Output Voltage Range See rating Chart V Io Output Current Range See rating Chart A 0.95 0.97 1.0 180 0 W Iil Input Current (Low Line) Io=Full load, Vin=115VAC 2.3 Iih Input Current (High Line) 0.9 A A I rl Low Line Inrush Current I rh High Line Inrush Current Eff Efficiency Io=Full load, Io=Full load, Vin=115VAC Io=Full load, Vin=230VAC Io=Full load, Vin=230VAC 25 C,Cool start, 48 54 A 25 C,Cool start, 100 108 A 88 90 % REG-i Line Regulation Io=Full load REG -o Load Regulation 0.5 1 % 3 5 % OVP Over Voltage Protection 112 132 % OCP Over Current Protection 110 150 % Ttr Time of Transient Response Io=Full load to Half Load, Vin=100VAC 4 mS Vin=230VAC 85 Vin=230VAC Thold Hold-Up Time Io=Full load, Vin=110VAC 16 Ts Start Up Time Io=Full load, Vin=100VAC 0.3 Vp-p Ilk TC mS 1 2 Ripple & Noise (Peak to Peak) Full load, Vin=90VAC 0.5 1 Safety Ground Leakage Current Io=Full load, Vin=240VAC 0.5 0.75 Temperature All output Coefficient -0.04 0.04 S % mA %/ C Environmental : Sym. Parameter Toper Operating Temperature Tstg Storage Temperature Hr T e s t Conditions Relative Humidity MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F Pd Derate linearly from 100% load at 50 C to 50% load at 70 C Min. Typ. Max. Unit 0 70 -40 85 C 5 95 % 0.1M C Hrs SUU180 SERIES 180W U-bracket Switching Power Supplies For I.T.E. Safety Specifications: Sym. Parameter Min. Typ. Max. Unit Primary to secondary 4242 VDC Primary to ground 2121 VDC 50 B B M CLASS CLASS T e s t Conditions Dielectric Withstanding Voltage Vps for Primary to secondary Dielectric Withstanding Voltage Vpg for Primary to Ground Ris Isolation Resistance CISPR EMI requirements for CISPR-22 FCC EMI requirements for FCC PART-15 Test Voltage=500VDC Vin=220VAC Vin=110VAC Output Voltage And Current Rating Chart (Single Output) : Output Voltage Model Number * Output Current Total Regulation Maximum Output Power SUU180-105 12 VDC 14.58 A 5% 175W SUU180-108 24 VDC 7.50 A 3% 180W SUU180-111 48 VDC 3.75 A 2% 180W " * " : 12V models are required to use DINKLE#DT-2N-B01W-04. PIN CHART PIN 1 2 3 4 5 6 7 Note: 1. Dimensions are shown in mm . 2. Weight: 521gs approx. 3. Input connector mates with Molex housing 09-50-3031 and Molex 2478 series crimp terminal. 4. Output connector mates with Molex housing 09-50-3081 and Molex 2478 series crimp terminal. 8 MODEL SU U1 80-1XX RTN RTN RTN RTN OUT OUT OUT OUT Mechanical Specifications : 8 P1 L ED P2 1 (SUU180-105 ONLY) 12V models are required to use screw terminal L N AC INPUT