SPECIFICATION CONTROL DRAWING Product Revision Product Name D-101-33 D-101-34 D-101-35 D-101-36 L max J K J J 17.0 (0.670) ‘XY’ = WIRE GAUGE (AWG) Product Dimensions øA øB K min min min 4.30 (0.170) 5.00 (0.200) AWG 150 (5.900) 22 22 20 20 øD max 4.30 (0.170) Cable Dimensions øE J±0.5 min (J±0.02) 1.78 (0.070) 7.00 (0.275) Color of Item 4 black white black white MATERIALS 1. INSULATION SLEEVE: Heat-shrinkable, transparent blue, radiation cross-linked polyvinylidene fluoride. 2. SOLDER PREFORM WITH FLUX: SOLDER: TYPE Sn63 per ANSI-J-STD-006. FLUX: TYPE ROL1 per ANSI-J-STD-004. THERMAL INDICATOR: red. 3. MELTABLE RINGS: Thermally stabilized thermoplastic. Color:gray. 4. GROUND LEAD: Raychem 55A0111-XY in accordance with MIL-W-22759/32 AWG ‘XY’ (see table) stranded tin plated copper. Color: see table. APPLICATION 1. These parts are designed to provide an environment protected shield termination on cables, rated for 125°C minimum, meeting the dimensional criteria listed, having tin or silverplated copper shields. 2. Temperature range: -55°C to +150°C. Install using Raychem-approved convection or infrared heating tools in accordance with Raychem process standard RCPS-100-70. For best results, prepare the cable as shown: * A trademark of TE Connectivity. THERMOFIT DEVICES TE connectivity 300 Constitution Drive Menlo Park, CA 94025 USA UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS. INCHES DIMENSIONS ARE BETWEEN BRACKETS. TOLERANCES: ANGLES: N/A TE Connectivity reserves the right to amend 0.00 N/A this drawing at any time. Users should evaluate 0.0 N/A ROUGHNESS IN the suitability of the product for their 0 N/A MICRON application. TITLE: SOLDERSLEEVE* DEVICE WITH PRE-INSTALLED LEAD DOCUMENT NO.: D-101-3X DCR NUMBER: REPLACES: D981004 DRAWN BY: DATE: PROD. REV. DOC ISSUE: SCALE: M. FORONDA 06/15/98 SEE TABLE 5 None Print Date: 11-May-11 If this document is printed it becomes uncontrolled. Check for the latest revision D1013X SIZE: A SHEET: 1 of 1