DC-AC INVERTER UNIT - Power

DC-AC INVERTER UNIT
PS-M06D12S5-NJ4L-099(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC/AC inverter is developed for dual lamps.
Optimized for Toshiba : LTA065B0D0F
APPLICABLE LCD:
6.4 to 12 inches double lams
Lamp Voltage 520 Vrms
Lamp Current 6 mArms
Lamp Start Up Voltage 1.450 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Ext. PWM dimming function
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
LxWxH
105 x 22,5 x 10mm
13 ± 0.5
PS-MXXDXX-NJX
29/01/2004
MADE IN
GERMANY
CN2
CN1-1
82 ± 0.3
CN1
5 ± 0.5
105 ± 0.5
(2)
15 ± 0.3
22,5 ± 0.5
DIMENSIONS :
-10°C ~ +60°C
-20°C ~ +85°C
95 %RH max
CAUTION
HIGH VOLTAGE
CN2-1
CN1-5
10.0MAX
CN2-4
3
2 - Ø2.5 ± 0.2
(for M2 screws)
2
(2)
1
Unit : mm
Weight :20 (g) typ.
High Voltage generation area 60mm
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2
Qty.
1
1
1
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-SM3
SM04(4.0)B-BHS
Output side CN2:
Input side CN1:
Pin No. Symbols
CN 1-1
Vin
CN 1-2
GND
CN 1-3 Ext. PWM
CN 1-4
N.C.
CN 1-5
Vrmt
Note
t=1.6m m
JST or equal
JST or equal
Pin No.
CN 2-1+2
CN 2-3
CN 2-4
Ratings
12 Vdc
0 ~ 5 Vdc (L activ)
Symbols
Vhigh
N.C.
Vlow
Ratings
520 Vrms (6 mArms)
0 Vdc
0 / 5 Vdc (H activ)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0.3, 20th May 2014
DC-AC INVERTER UNIT
PS-M06D12S5-NJ4L-099(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Note 1 :
Note 2:
Note 3:
Symbols
Iout
Iout
Iin
F
Vopen
Vin (V) Vrmt (V)
12±0.12
12±1.2
12±1.2
12±1.2
11,4
5±0.25
5±0.25
5±0.25
5±0.25
5±0.25
Specification
Tu (°C)
Min.
Typ.
Max.
-10 ~ +60
-10 ~ +60
-10 ~ +60
-10 ~ +60
-10 ~ +60
5.5
5.0
45
1.200
6.0
6.0
0.7
55
-
6.5
7.0
1.2
65
-
Unit
Note
mArms
mArms
Adc
kHz
Vrms
Duty 100%
Please keep a minimum of 2mm clearance in all directions between inverter high voltage areas
and any conductors.
Remote ON/OFF (CN1-5) has priority and can not be used in combination with External PWM Dimming
(CN1-3). When 'Ext.PWM' (CN1-3) is used 'Vrmt' (CN1-5) should not be connected.
The external PWM-frequency should be within the range of 100 ~ 500Hz. For other frequencies
please request. The optimum frequency is normally 250 Hz and this minimizes
the interference of the vertical sync frequency.
TEST CIRCUIT :
SW 1
Operation of unit
a
Operation
b
Non operation
EXTERNAL PWM-DIMMING ( Remote ON / OFF Detailed Circuit Diagram ):
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.0.3, 20th May 2014