FMBB 1-Phase Line Filters www.schurter.com/pg06_1 AC Filter 2-Stage, Broad Band Attenuation Description -Chassis: Screw-on mounting, from top -Line-filter in standard version, 2 positions, very high attenuation -Very high symmetrical and asymmetrical attenuation loss in the frequency range from 10kHz up to 30MHz Approvals -VDE License Number: 40004673 -UL License Number: E72928 Characteristics -Designed for high current applications -Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated -Especially designed for industrial applications such as: Frequency Converters, Stepper Motor Drives, UPS-Systems, Inverters -Qualified for use in equipment according IEC/EN 60950 Other versions on request -Version with wire connection References General Product Information Weblinks Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store, Distributor-Stock-Check, Accessories Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temp. Climatic Category Protection Class Terminal Material: Housing 8 - 25 A @ Ta 40 °C / 250 VAC; 50 Hz 8 - 25 A @ Ta 40 °C / 125 VAC; 60 Hz industrial < 3.5 mA ( V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 °C to 100 °C 25/100/21 acc. to IEC 60068-1 Suitable for appliances with protection class 1 acc. to IEC 61140 Screw Metal Line Filter MTBF EMC Products Standard and Industrial Version, IEC 60939, IEC 60601‑1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details > 200'000 h acc. to MIL-HB-217 F FMBB 1-Phase Line Filters www.schurter.com/pg06_1 Dimensions Case 24-2 Case 16-2 max. 100 3) (9) (27) 1) (20) 5.3 ±0.2 M4 max. 54 (29.5) max. 47 max. 87.5 ±0.5 4) max. 86 +0 max. 58 (7) 2) 1) 95 -1 max. 106 max. 137 max. 100 2) M6 5.3 ±0.3 3) 51 ±0.3 (15) (17) (12) max. 78 1) Line2) Load3) Nut torque 3...4 Nm. 1) Line2) Load3) Nut torque 3...4 Nm4) Do not unscrew lock-nut Case 31-2 Case 31-6 !! max. 61 max. 217 (7) max. 61 (1) 6.5 ±0.3 115 ±0.3 6.5 ±0.3 1) Line2) Load3) Nut torque 3...4 Nm 1) Line 2) Load M6 115 ±0.3 3) (17) S2 standard version 2) 1) 2) 1) Line 2) Load Attenuation Loss - - - - differential mode _____ common mode Standard version 8A 2) 1) Line2) Load3) Nut torque 3...4 Nm Diagrams S1 standard version 1) +0 (17) 1) (30) M6 3) 100 -1 2) max. 116 max. 86 1) (30) +0 100 -1 max. 116 max. 181 max. 86 max. 217 max. 181 EMC Products FMBB 1-Phase Line Filters www.schurter.com/pg06_1 Industrial Version 12 A 16 A 25 A Variants Rated Current Filter-Type [A] Leakage Current [mA] L [mH] C1 (X2) [μF] C2 (X2) [µF] C3 (X2) [µF] C4 (Y2) [nF] C5 (Y2) [nF] R1, R2 [MΩ] Diagram Clamps [mm2] Weight [g] Housing Order Number 8 Standard Version 0.25 2x7 0.1 0.15 0.47 2.2 - 1 S1 4 410 16-2 5500.2068 12 Industrial Version 3.5 2x5 2.2 2.2 2.2 33 2.2 0.5 S2 4 1000 24-2 5500.2069 16 Industrial Version 3.5 2 x 3.5 2.2 2.2 2.2 33 2.2 0.5 S2 4 2400 31-2 5500.2070 25 Industrial Version 3.5 2 x 3.5 2.2 2.2 2.2 33 2.2 0.5 S2 6 2500 31-6 5500.2071 Packaging unit 5 Pcs The specifications, descriptions and illustrations indicated in this document are based on EMC Products current information. All content is subject to modifications and amendments.