SEMIKRON SKCD61C060I3

SKCD 61 C 060 I3
Absolute Maximum Ratings
Symbol
Conditions
Values
Unit
VRRM
IF(AV)
Tj = 25 °C, IR = 0.2 mA
600
V
Ts = 80 °C, Tj = 150 °C
75
A
IFSM
10 ms
sin 180°
1000
A
150
°C
Tj = 25 °C
A
Tj = 150 °C
Tjmax
CAL-DIODE
Electrical Characteristics
Symbol
Conditions
IF = 100 A
i2t
Tj = 150 °C, 10 ms, sin 180°
VRRM = 600 V
IR
Size: 7,8 mm x 7,8 mm
SKCD 61 C 060 I3
min.
typ.
max.
Unit
5000
A2s
Tj = 25 °C, VRRM = 600 V
0.20
mA
Tj = 125 °C, VRRM = 600 V
6.00
mA
Tj = 25 °C, IF = 110 A
1.35
1.60
V
Tj = 125 °C, IF = 110 A
1.35
1.60
V
V(TO)
Tj = 125 °C
0.90
V
rT
Tj = 125 °C
3.8
mΩ
VF
Features
Dynamic Characteristics
• low forward voltage drop combined
with a low temperature dependence
• easy paralleling due to a small forward
voltage spread
• very soft recovery behavior
• small switching losses
• high ruggedness
• compatible to thick wire bonding
• compatible to all standard solder
processes
Symbol
Conditions
trr
Tj = 25 °C, 100 A, 300 V, 800 A/µs
trr
Tj = 125 °C, 100 A, 300 V, 800 A/µs
Qrr
Tj = 25 °C, 100 A, 300 V, 800 A/µs
3
µC
Qrr
Tj = 125 °C, 100 A, 300 V, 800 A/µs
7
µC
Irrm
Tj = 25 °C, 100 A, 300 V, 800 A/µs
Irrm
Tj = 125 °C, 100 A, 300 V, 800 A/µs
Typical Applications*
• freewheeling diode for IGBT
min.
typ.
max.
Unit
µs
ns
A
60
A
Thermal Characteristics
Symbol
Conditions
min.
typ.
max.
Unit
°C
Tj
-40
150
Tstg
-40
150
°C
Tsolder
10 min.
250
°C
Tsolder
5 min.
320
°C
Rth(j-s)
sold. on 0,38 mm DCB, reference point
on copper heatsink close to the chip
0.54
K/W
Values
Unit
7.8 x 7.8
mm2
60.84
mm2
Mechanical Characteristics
Symbol
Conditions
Raster
size
Area total
Anode
bondable (Al)
Cathode
solderable (Ag/Ni)
Al, diameter ≤ 500 µm
Wire bond
Package
wafer frame
Chips /
Package
156 (5" Wafer)
pcs
SKCD
© by SEMIKRON
Rev. 0 – 18.02.2010
1
SKCD 61 C 060 I3
This is an electrostatic discharge sensitive device (ESDS), international standard IEC 60747-1, Chapter IX