SEMIKRON SKCD81C170IHD

SKCD 81 C 170 I HD
Absolute Maximum Ratings
Symbol
Conditions
Values
Unit
VRRM
IF(AV)
Tj = 25 °C, IR = 0.1 mA
1700
V
Ts = 80 °C, Tj = 150 °C
85
A
IFSM
10 ms
sin 180°
Tj = 25 °C
1370
A
Tj = 150 °C
1070
A
150
°C
Tjmax
CAL-DIODE
Electrical Characteristics
Symbol
Conditions
IF = 150 A
i2t
VRRM = 1700 V
IR
Size: 9 mm x 9 mm
SKCD 81 C 170 I HD
min.
typ.
max.
Unit
Tj = 150 °C, 10 ms, sin 180°
5720
A2s
Tj = 25 °C, VRRM = 1700 V
0.10
mA
Tj = 125 °C, VRRM = 1700 V
mA
Tj = 25 °C, IF = 150 A
1.73
2.02
V
Tj = 125 °C, IF = 150 A
1.78
2.05
V
V(TO)
Tj = 125 °C
1.03
V
rT
Tj = 125 °C
5.0
mΩ
VF
Features
Dynamic Characteristics
• high current density
• easy paralleling due to a small forward
voltage spread
• positive temperature coefficient
• very soft recovery behavior
• small switching losses
• high ruggedness
• compatible to thick wire bonding
• compatible to standard solder
processes
Symbol
Conditions
trr
Tj = 25 °C, 150 A, 1200 V, 1125 A/µs
trr
Tj = 125 °C, 150 A, 1200 V, 1125 A/µs
Qrr
Tj = 25 °C, 150 A, 1200 V, 1125 A/µs
25
µC
Qrr
Tj = 125 °C, 150 A, 1200 V, 1125 A/µs
44
µC
Irrm
Tj = 25 °C, 150 A, 1200 V, 1125 A/µs
83
A
Irrm
Tj = 125 °C, 150 A, 1200 V, 1125 A/µs
102
A
Typical Applications*
Thermal Characteristics
• freewheeling diode for IGBT
• particularly suitable for frequencies < 8
kHz
Symbol
Conditions
min.
typ.
max.
Unit
µs
ns
min.
typ.
max.
Unit
°C
Tj
-40
150
Tstg
-40
150
°C
Tsolder
10 min.
250
°C
Tsolder
5 min.
320
°C
Rth(j-s)
sold. on 0,38 mm DCB, reference point
on copper heatsink close to the chip
0.4
K/W
Values
Unit
9x9
mm2
81
mm2
Mechanical Characteristics
Symbol
Conditions
Raster
size
Area total
Anode
bondable (Al)
Cathode
solderable (Ag/Ni)
Al, diameter ≤ 500 µm
Wire bond
Package
wafer frame
Chips /
Package
116 (5" Wafer)
pcs
SKCD
© by SEMIKRON
Rev. 1 – 18.02.2010
1
SKCD 81 C 170 I HD
This is an electrostatic discharge sensitive device (ESDS), international standard IEC 60747-1, Chapter IX
* The specifications of our components may not be considered as an assurance of component characteristics. Components have to be tested
for the respective application. Adjustments may be necessary. The use of SEMIKRON products in life support appliances and systems is
subject to prior specification and written approval by SEMIKRON. We therefore strongly recommend prior consultation of our personal.
2
Rev. 1 – 18.02.2010
© by SEMIKRON