VITESSE VSC880TY

VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
Features
• Serial Data Rates: 2.0Gb/s
• Supports Variable Length Packets in Packet
Mode
• 32Gb/s Aggregate Data Bandwidth
• Built-in Flow Control Channel in Packet Mode
• Parallel Switches Can Increase Data Bandwidth in
Multiples of 32Gb/s
• Supports Cell Synchronization in Cell Mode
• 16x16 Synchronous Serial Crosspoint Switch
• Parallel CPU Interface and Parallel Switch
Configuration Interface
• Designed in Conjunction with the VSC870
Backplane Transceiver
• Loopback, Built-in Self Test and Scan Functions
• 5V Tolerant TTL Inputs
• Automatic Word and Cell Synchronization to the
Transceiver
• Dual 3.3V/2.5V or Dual 3.3V/2.0V Power
Supplies
• Two Modes of Operation: Distributed Control
Self-routing Packet Mode and Central Control
Cell Mode
• Serial Port Quadrants Can be Powered Down
• Available in 304 BGA Package
• Multicast Supported in All Modes
VSC880 Block Diagram
Serial Port (16x)
Switch Matrix
Parallel
to
Serial
TXS+/TXS-
MEN
FACLPBK
CMODE
Port
TESTEN
SCANIN
SCANOUT
Logic
RXS+/RXS-
WCLK
REFCLK
TCLKEN
LOCKDET
CCLK
DRU
Serial
to
Parallel
Arbitration Logic
and Switch Control
Registers
Clock
Gen
FI[3:0]
WEN
ADDR[5:0]
Status and
Control Registers
BIST Logic
BSTPASS
G52191-0, Rev 4.2
01/05/01
CEN
DATA[15:0]
CMU
RESET
BSTLPBK
BSTEN
BSTRST
VSCTE
VSCIPNC
VSCOPNC
CDATA[7:0]
CWEN
CSEL
INT
RESYNEN
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
Page 1
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
General Description
The VSC880 is a 16x16 serial crosspoint switch with serial data rates at 2.125Gb/s. The VSC880 has been
designed to operate with the VSC870 backplane transceiver to establish a synchronous high performance switching
system with an aggregate bandwidth of 32Gb/s. The switch chip transmits the master word clock (62.5Mb/s), and
master cell clock (if used) to all port cards through the serial data channels. The transceivers automatically perform
bit alignment, word alignment and cell alignment to the switch chip. The transceiver and switch chip have been
optimized for both self-routing and cell-based systems and include special commands for connection requests (selfrouting) and cell synchronous operation (cell based). In addition, a parallel CPU interface can be used to control
internal modes and read status information from the switch. A 20-bit interface can also be used to program the switch
matrix in 4 clock cycles. The switch chip runs off of a 3.3V/2.5V or 3.3V/2.0V power supplies. The serial I/O buffers
contain on-chip termination resistors (see Application Note 34).
Pin Descriptions
Pin
Name
I/O
Freq
Type
TXS[15:0]+/
TXS[15:0]-
Transmit Serial Outputs
O
2.125Gb/s
LVDS
16 high speed serial differential transmit channels
RXS[15:0]+/
RXS[15:0]-
Receive Serial Inputs
I
2.125Gb/s
LVDS
16 high speed serial differential receive channels
DATA[15:0]
Configuration Data Input
I
62.5Mb/s
TTL
Parallel input signals used to program the switch matrix in 4
clock cycles when the signal CEN is LOW.
FI[3:0]
Force IDLE Input
I
62.5Mb/s
TTL
Parallel input signals used to program force IDLE words at
the switch matrix output in 4 clock cycles when the signal
CEN is LOW.
CEN
Configure Enable
I
62.5Mb/s
TTL
When CEN is held LOW, the inputs DATA[15:0] and FI[3:0]
can be used to program the switch matrix in 4 word clock
cycles timed to the WEN signal.
WEN
Write Enable
I
62.5Mb/s
TTL
If CEN is LOW, this signal provides a synchronization pulse
for loading switch configuration data into DATA[15:0] and
FI[3:0].
ADDR[5:0]
Data Address
I
62.5Mb/s
TTL
The address to read and write data through parallel interface
CDATA[7:0].
I
62.5Mb/s
TTL
This signal allows several switch chips to share an 8 bit data
bus connected to CDATA[7:0]. If CSEL is LOW, data will
be read or written to CDATA[7:0]. If CSEL is HIGH, the
outputs will be high impedance and the inputs disabled.
Bidirectional CPU interface for the status and control
registers. If CSEL is LOW, the data will be read or written
into this port. If CSEL is HIGH, the outputs will be high
impedance and the inputs will be disabled.
This signal is set HIGH to read the internal status registers
through the parallel interface CDATA[7:0]. It is set LOW to
write into this interface.
CSEL
Page 2
Chip Select
CDATA[7:0]
Status Data Output
B
62.5Mb/s
TTL
CWEN
Control Write Enable
I
62.5Mb/s
TTL
Description
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
G52191-0, Rev 4.2
01/05/01
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
Pin
Name
I/O
Freq
Type
Description
RESYNEN
Resynch Enable
I
<1MHz
TTL
If RESYNEN is HIGH, all links that have a link error
condition will be reinitialized. This will override the internal
control register settings.
INT
Interrupt
O
<1MHz
TTL
If INT is LOW, a receive error has occurred in one of the
links that has it’s output enable (OE) bit set HIGH and
interrupt control register bit set HIGH.
MEN
Reserved
I
<1MHz
TTL
This signal is reserved for future use and should be set LOW
during normal operation.
FACLPBK
Facility Loop Back
I
<1MHz
TTL
If this signal is set HIGH, all serial inputs are looped back to
their serial outputs. This will override the internal control
register setting.
CMODE
Cell Mode
I
<1MHz
TTL
CMODE is set HIGH for Cell Mode operation.
TESTEN
Scan Test Enable
I
<1MHz
TTL
This signal is used in ATE testing to measure propagation
delay. It is also used in ATE testing of the BIST logic. Set to
logic LOW in normal operation.
SCANIN
Scan Data In
I
62.5Mb/s
TTL
The input signal for measuring propagation delay on the
ATE tester.
SCANOUT
Scan Data Out
O
62.5Mb/s
TTL
The output signal for measuring propagation delay on the
ATE tester. When TESTEN is set LOW, the longer delay
path is enabled.
WCLK
Word Clock
O
62.5MHz
TTL
This is the word clock output.
REFCLK
Reference Clock
I
62.5MHz
TTL
This is the reference clock and the source of the system wide
word clock period.
TCLKEN
Test Clock Enable
I
<1MHz
TTL
This input is set HIGH in test mode, so that the CMU is
bypassed and the REFCLK becomes the bit clock. This
signal is for ATE test only. Set LOW in normal operation.
This is the source of the system wide cell clock. It is
internally synchronized to the REFCLK. In Packet mode, set
this signal HIGH to enable external switch configuration for
BIST.
CCLK
Cell Clock
I
62.5MHz
TTL
RESET
Reset
I
<1MHz
TTL
Global chip reset (active LOW)
BSTLPBK
Built-in Self Test Loop
Back
I
<1MHz
TTL
When BSTLPBK is set HIGH and TESTEN is LOW, all
serial data output signals are looped back to their serial data
inputs. If BSTLPBK is set HIGH and TESTEN is HIGH,
only ports 0-7 are placed in loopback.
BSTEN
Built-in Self Test Enable
I
<1MHz
TTL
When BSTEN is HIGH, at-speed built-in self testing is
enabled.
BSTRST
Built-in Self Test Reset
I
<1MHz
TTL
The BSTRST signal is set HIGH to reset the PRBS
generator and comparator.
BSTPASS
Built-in Self Test Pass
O
<1MHz
TTL
The BSTPASS signal is HIGH if BTSEN is HIGH and the
PRBS comparator detects the correct pattern in built-in self
test mode.
G52191-0, Rev 4.2
01/05/01
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
Page 3
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
Pin
Name
I/O
Freq
Type
LOCKDET
CMU Lock Detect
O
<1MHz
TTL
This signal is LOW while the CMU is acquiring lock.
VSCTE
NOR Chain Test Enable
I
<1MHz
TTL
Used for ATE testing of the parametric NOR chain in the I/O
frame. Set to logic LOW during normal operation.
VSCIPNC
NOR Chain Input
I
<1MHz
TTL
Used for ATE testing of the parametric NOR chain in the I/O
frame. Set to logic LOW during normal operation.
VSCOPNC
NOR Chain Output
O
<1MHz
VECL
Used for ATE testing of the parametric NOR chain in the I/O
frame. Leave output open during normal operation.
VDD1, VDD2,
VDD3, VDD4
Serial Port Power
Supplies
P
3.3V
VDD1 = Serial Port 0-3 power supply
VDD2 = Serial Port 4-7 power supply
VDD3 = Serial Port 8-11 power supply
VDD4 = Serial Port 12-15 power supply
VDDA
CMU Power Supply
P
3.3V
Clean power supply for CMU
VSSA
CMU Ground
P
0V
VMM
Core Power Supply
P
2 ~ 2.5V
Description
Clean ground for CMU
Core power supply
Functional Description
The VSC880 switch can be used in conjunction with the VSC870 transceivers to support two modes of
operation: Packet Mode and Cell Mode. In Packet mode, the chip set provides a switching system to support variable
length, self-routing data packets. In Cell Mode, the chip set provides a cell synchronous switching system with a user
defined scheduler. In this mode, it can support only fixed length data packets (cells). Routing decisions are carried
out in the scheduler and crosspoint configuration is synchronized to a cell clock. The scheduler configures the switch
matrix using the parallel interface. To conserve power, each serial port quadrant can be powered down if not used.
The following section gives a detailed functional description of the operation of the switch chip. Most of the
discussion includes some of the transceiver operation (see the VSC870 data sheet). The two major operation modes
are described separately in the Packet Mode and the Cell Mode sections.
1.0 Common Features
1.1 Synchronization
1.1.1 Link Characteristic
The serial link is used to connect the switch chip to transceivers. These links operate at 2.125 Gb/s and are
initialized simultaneously at power up, or separately when a link error occurs. A link is first bit synchronized, then
word synchronized and, if CMODE is HIGH, cell synchronized. In Packet or Cell mode, the switch acts as the
master, generating the bit clock along with the word and cell boundary information. The transceivers act as slaves,
recovering the bit clock, word clock and cell clock. The transceiver also contains redundant serial inputs and outputs
which can be used with a redundant switch chip.
Page 4
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
G52191-0, Rev 4.2
01/05/01
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
1.1.2 Data Scrambling
To allow the VSC870 CRU to recover the bit clock, a 15% edge transition density must be guaranteed on the
serial data links. All command words and connection request words contain this required density. In order to get this
density on data words, scrambling must be employed by the transceiver (see VSC870 data sheet).
1.1.3 Bit Synchronization
In Packet Mode and Cell Mode, the switch acts as the source of the bit clock. It multiplies the local 62.5MHz
reference clock by 34 to generate a 2.125GHz clock and uses this clock to serialize the 32-bit word and 2 overhead
bits. The transceiver receives and feeds this serial data stream to a digital CRU to recover the bit clock and
deserialize the data stream to a 32-bit word plus 2 overhead bits at 62.5MHz. The transceiver also uses this recovered
clock to serialize its transmit words that are sent to the switch. In this way, the switch and all the transceivers are
frequency-locked to one clock source which is provided by the reference clock on the switch card. Because of this,
the switch chip needs to recover only the phase information on the serial receive channel using a data recovery unit
(DRU). The DRU is designed as a delay lock loop and remains phase-locked to the incoming data stream as long as
the temperature does not change by more than 20°C after link initialization. If this temperature variation is exceeded,
a link error may occur causing the link to reinitialize. Because of this, system reset should be held until the system
reaches temperature stability before starting the link initializing process.
1.1.4 Word Synchronization
During power up or at reset, the transceiver can initiate the word synchronization process. First, the transceiver
sends reset patterns to the switch to request that the switch starts the initialization process. The switch, upon
receiving this request, will send out special ALIGN words. The transceiver receives this serial data stream and word
aligns to this ALIGN word by adjusting its own word boundary one bit at a time. Upon detecting the correct word
alignment, it starts the transmit word alignment process. In this process, the transceiver continuously sends ALIGN
words to the switch. The switch uses its own word clock (REFCLK) to detect this ALIGN word. If the transmitters
word is not aligned to the switch chip word clock when it arrives at the switch, the switch chip continues to send out
ALIGN words. After receiving 32 ALIGN words from the switch chip, the transceiver changes its transmit word
boundary by 1 bit position and repeats the process (this limits the distance from the transceiver to the switch to less
than 180ns one way). If the switch detects the transceivers ALIGN word correctly, it sends IDLE words to the
transceiver to signal that the transmitter has now word synchronized with the switch. It also clears the internal
registers LERR, TERR, DERR and CERR and sets the signal INT HIGH if all the enabled serial channels are
successfully initialized (see section 1.4).
1.1.5 Cell Synchronization
If CMODE is set HIGH, after the word synchronization process completes, the transceiver starts the cell
synchronization process. In this process, the transceiver detects the received cell clock (CCLK) sent from the switch
embedded in the alignment word. The switch delays the global cell clock to adjust out the pipeline delay from the
transceiver to the switch. The switch chip does this by connecting each port to itself during link initialization. By
sending an ALIGN words to itself, the transceiver can adjust the transmit clock until it is properly phase shifted
relative to the global cell clock. If cells are sent from the transceiver aligned to this transmit cell clock, they will
arrive at the switch aligned to the master cell clock which is originated at the switch. For this alignment process to
work, the minimum cell size is 8 words (32 bytes).
G52191-0, Rev 4.2
01/05/01
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
Page 5
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
1.1.6 Link Error Detection
There are four types of link errors that can be flagged on the receive serial links. Link errors are detected using
IDLE words. If a link error is detected, a bit in the LERR register is set HIGH for that particular channel (see section
1.4). After every 8 link errors, a bit in the TERR register is set HIGH. If the DRU goes out of range, a bit in the DERR
register is set HIGH. If the last word in the cell period is an IDLE word and it does not have bits B[1:0] set HIGH to
designate a cell clock, a bit in the CERR register will be set HIGH. If an error bit is set in any of these registers, the
INT signal can be programmed to go LOW and/or the link can be programmed to automatically start link
initialization depending on the value loaded into the Interrupt Control Register (see section 1.4). These error register
bits will be cleared if the link is reinitialized, or the registers are read. If the signal RESYNEN is set HIGH, link
initialization will begin immediately upon the detection of any of these errors. If the switch is used without IDLE
words, the user is responsible for detecting parity error conditions and restarting the link initialization process.
1.2 Data Encoding Format
To provide self-routing and cell synchronization, the transceiver and switch require special word formats.
Depending on the mode that the switch is used in, different word types are recognized by the switch. In both the
Packet and Cell Modes, the switch processes both data words and command words. They have the same format in
both modes and will be described in following section. The format for the connection request words and header
words are described later in the Packet Mode section.
1.2.1 Data Word Format on the Serial Data Lines
The data word format as seen at the serial output of the transceiver or switch chip is shown below. Two overhead
bits are added by the transceiver or switch chip to designate a data word to the receiving switch chip or transceiver.
The serial data is transmitted with the MSB first.
33 32
31 30 29 28
27 26 25 24
23 22 21 20
19 18 17 16
15 14 13 12
11 10 09 08
07 06 05 04
03 02 01 00
B B
1 0
D D D D
31 30 29 28
D D D D
27 26 25 24
D D D D
23 22 21 20
D D D D
19 18 17 16
D D D D
15 14 13 12
D D D D
11 10 09 08
D D D D
07 06 05 04
D D D D
03 02 01 00
--------------- Data Payload ----------------
Where:
B[1:0]If Packet Mode,
01=Flow control channel,
10=Flow control channel,
11=Acknowledge from switch chip or header word to switch chip
If Cell Mode,
01, 10, 11 = data
D[31:0]32 bit data payload
1.2.2 Command Word Format on the Serial Data Lines
The command word format as seen at the serial output of the transceiver or switch chip is shown below. Two
overhead bits are added by the transceiver or switch to designate a command word (00) to the receiving switch chip or
transceiver. The serial data is transmitted with the MSB first. In Packet Mode, the IDLE word from the switch always
returns the current output connections for the port.
Page 6
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
G52191-0, Rev 4.2
01/05/01
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
33 32
31 30 29
28 27 26 25 24
23 22 21 20
19 18 17 16
15 14 13 12
11 10 09 08
07 06 05 04
03 02 01 00
0 0
1 B B
1 0
C C C C C
04 03 02 01 00
D D D D
15 14 13 12
D D D D
11 10 09 08
D D D D
07 06 05 04
D D D D
03 02 01 00
1 0 1 0
1 0 1 0
-- Command --
-- Data --
Where:
B[1:0]00=Undefined (during normal operation) or alignment word
01=Flow control channel,
10=Flow control channel,
11=Acknowledge (from switch chip only) or link initialization reset or cell clock in cell mode
C[4:0]Command type
00XXX=Link Control (00000=ALIGN word, 00111=IDLE word)
01XX0=Command word for transceiver (01000=set DLYEN/CCKIN value)
10XX0=Command word for switch
11XX0=Command word for receiving port card (TBD)
D[15:0]Optional data payload
Default=1010101010101010
IDLE Word from switch=Current switch outputs this port is connected to
D[15] is for port 0, D[0] is for port 15
If C[4:0]=01000, D[3:0]=DLYEN/CCKIN value
1.2.3 IDLE Words
IDLE words are the default word used on the serial channel when none of the other word types are present. In
most cases, these words are automatically generated by the transceiver or switch chip. In Packet Mode, IDLE words
are inserted between packets and the IDLE word from the switch always returns the current output connections for
the port that is receiving the IDLEs. These connection bits will be in the same location as in the CRQ word. In cell
mode, IDLEs will be transmitted from the switch chip if the force IDLE (FI) bit is set in the control registers. IDLE
words are also used to detect link error conditions. If the switch chip detects an IDLE word, it uses a bit mask to verify the proper bit pattern within the word.
1.3 Loopback
The VSC880 supports a loopback function at the serial interfaces which is used in built-in self-test mode. If the
BSTLPBK signal is set HIGH and TESTEN is set LOW, the serial transmit data is looped back to the serial receive
side for all 16 channels. If the BSTLPBK signal is set HIGH and TESTEN is set HIGH, the serial transmit data is
looped back to the serial receive side for channels 0-7 only. If the FACLPBK signal is set HIGH, the serial receive
signal is looped back to the serial output for all 16 channels. Each channel can also be programmed to be looped back
separately from serial input to serial output by using the control registers described below. The VSC880 does not
support simultaneous BIST and facilty loopback functions (either FACLPBK pin or LPBK[15:0] register).
1.4 Internal Register Definitions
The internal status and control registers are defined in the following table. The address signal ADDR[5:0] is used
along with CSEL and CWEN to read or write data through the CDATA[7:0] interface. CWEN is set LOW to write
and HIGH to read from this port. If CSEL is HIGH, the outputs become high impedance and the inputs become
G52191-0, Rev 4.2
01/05/01
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
Page 7
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
disabled. All data transfer timing is asynchronous to REFCLK. The Interrupt Control Register is written by the user
to mask certain operations. If ICE is set HIGH, the INT output pin will go LOW if any error bit is set in the CERR
register. If RCE is set HIGH, the link will automatically start link initialization if any error bit is set in the CERR
register. The corresponding pins can be used for the DERR, TERR and LERR registers. If the INT signal goes LOW,
the Interrupt Status Register can be read to determine which of the four registers received an error.
The CDEL[3:0] bits are used to program a value for the cell clock delay (see section 3.0). The switch matrix
status information can be read from the CN and FI registers. A serial link can be forced to reinitialize by writing a
HIGH into the RSY register. A serial output can be logically disabled by writing a HIGH into the OE register. A serial
input can be forced to loop back directly to a serial output by writing a HIGH into the LPBK register. All registers are
cleared upon RESET. Also, the LERR, TERR, DERR and CERR registers are cleared on reading.
Figure 1: Status and Control Register Definition
CDATA[7:0] Bit Position
ADDR[5:0]
R/W
X00000
R
X00001
R/W
X00010
R/W
7
RCE
6
RDE
5
RTE
4
RLE
3
2
1
0
CE
DE
TE
LE
Interrupt Status Register
ICE
IDE
ITE
ILE
Interrupt Control Register
BIST
CDEL[3:0]
BIST and Count Register
X 00011
Page 8
X00100
R
CERR[7:0]
CCLK error register LSB
X00101
R
CERR[15:8]
CCLK error register MSB
X00110
R
DERR[7:0]
DRU error register LSB
X00111
R
DERR[15:8]
DRU error register MSB
X01000
R
TERR[7:0]
Error threshold register LSB
X01001
R
TERR[15:8]
Error threshold register MSB
X01010
R
LERR[7:0]
Link error register LSB
X01011
R
LERR[15:8]
Link error register MSB
001100
R/W
C0[3:0]
C8[3:0]
Output0/Output8 Config
001101
R/W
C1[3:0]
C9[3:0]
Output1/Output9 Config
001110
R/W
C2[3:0]
C10[3:0]
Output2/Output10 Config
001111
R/W
C3[3:0]
C11[3:0]
Output3/Output11 Config
010000
R/W
C4[3:0]
C12[3:0]
Output4/Output12 Config
010001
R/W
C5[3:0]
C13[3:0]
Output5/Output13 Config
010010
R/W
C6[3:0]
C14[3:0]
Output6/Output14 Config
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
G52191-0, Rev 4.2
01/05/01
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
CDATA[7:0] Bit Position
ADDR[5:0]
R/W
7
6
5
4
3
2
1
0
010011
R/W
C7[3:0]
C15[3:0]
101100
R
S0[3:0]
S8[3:0]
Output0/Output8 Status
101101
R
S1[3:0]
S9[3:0]
Output1/Output9 Status
101110
R
S2[3:0]
S10[3:0]
Output2/Output10 Status
101111
R
S3[3:0]
S11[3:0]
Output3/Output11 Status
110000
R
S4[3:0]
S12[3:0]
Output4/Output12 Status
110001
R
S5[3:0]
S13[3:0]
Output5/Output13 Status
110010
R
S6[3:0]
S14[3:0]
Output6/Output14 Status
110011
R
S7[3:0]
S15[3:0]
Output7/Output15 Status
X10100
R/W
FI[7:0]
Force IDLEs LSB
X10101
R/W
FI[15:8]
Force IDLEs MSB
X10110
R/W
RSY[7:0]
Resynch LSB
X 10111
R/W
RSY[15:8]
Resynch MSB
X11000
R/W
OE[7:0]
Output Enable LSB
X11001
R/W
OE[15:8]
Output Enable MSB
X11010
R/W
LPBK[7:0]
Loopback LSB
X11011
R/W
LPBK[15:8]
Loopback MSB
Output7/Output15 Config
Where:
CE Cell clock errorRCE
Resynch on cell errorICE
Interrupt on cell error
DE DRU error RDE
Resynch on DRU errorIDE
Interrupt on DRU error
TE Threshold errorRTE
Resynch on thresh errorITE
Interrupt on threshold error
LE Link error RLE
Resynch on link errorILE
Interrupt on link error
BIST
Set this bit HIGH to test the BIST circuitry
CDEL[3:0]
Cell clock delay
CERR[15:0]Cell clock error register, bit 0 is channel 0 etc, Cleared on read
DERR[15:0]DRU error register, bit 0 is channel 0 etc. Cleared on read
TERR[15:0]Threshold error register, bit 0 is channel 0 etc. Cleared on read
LERR[15:0]Link error register, bit 0 is channel 0 etc, Cleared on read
CN[3:0]Switch configuration data. N is the output port number, [3:0] is the input port connected. Default = 0xF.
SN[3:0]Output status data. N is the output port number, SN[3:2] = 00 for normal operation.
01 for out of synch
10 for word synch in progress
11 for cell synch in progress
SN[1] = Output busy in packet mode
SN[0] = Connection valid in packet mode
G52191-0, Rev 4.2
01/05/01
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
Page 9
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
FI[15:0]Force IDLE register, bit 0 is channel 0 etc
RESY[15:0]Resynch register, bit 0 is channel 0 etc
OE[15:0]Output enable register, bit 0 is channel 0 etc
LPBK[15:0]Facility loopback register, bit 0 is channel 0 etc
1.5 Parallel CPU Interface
There is a parallel 8 bit CPU interface on the VSC880 that can be used to read and write the status and control
registers described above. This is an asynchronous interface that was design to operate with many common micro
controllers that are available. The functional timing diagrams for a write and a read are shown in the following
figures. Timing information can be found in the AC Characteristics section of this data sheet.
Figure 2: CPU Interface Functional Write Cycle Timing
CWEN
CSEL
ADDR
Valid Address
CDATA
Valid Data
Figure 3: CPU Interface Functional Read Cycle Timing
CWEN
CSEL
ADDR
Valid Address
Valid Data
CDATA
Hi-Z
1.6 Parallel Configuration Interface
In addition to reading and writing the switch configuration using the CPU interface as described above, the entire
switch matrix can be reprogrammed in 4 word clocks by setting the CEN signal LOW. If CEN is set LOW, the
parallel interface DATA[15:0] contains a 16 bit switch configuration input port, the inputs FI[3:0] load the FI bits and
the WEN signal becomes a programming signal as shown in the figure below. It takes 4 word clocks to load all 64 bits
of switch configuration data and 16 FI bits into holding registers. All data transfer timing is relative to REFCLK.
After data has been loaded, and if CCLK is HIGH, all 80 bits of data are strobed into the switch matrix and FI control
logic. Otherwise, the configuration information is stored in holding registers until the next CCLK pulse strobes it in.
Since the CCLK signal is delayed internally in the switch, it can be asserted as early as the WEN signal pulse to
strobe in the configuration information.
Page 10
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
G52191-0, Rev 4.2
01/05/01
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
Figure 4: Switch Configuration Interface Functional Timing (CEN=0)
REFCLK
FI[3:0]
F0
F1
F2
F3
DATA[15:0]
C0
C1
C2
C3
WEN
Switch updated in this cycle
CCLK
Min. of 5 Cycles
The switch configuration data for each port is as follows:
F0[3:0] = FI[port9], FI[port8], FI[port1], FI[port0]
F1[3:0] = FI[port11], FI[port10], FI[port3], FI[port2]
F2[3:0] = FI[port13], FI[port12], FI[port5], FI[port4]
F3[3:0] = FI[port15], FI[port14], FI[port7], FI[port6]
C0[15:0] = Port9[3:0], Port8[3:0], Port1[3:0], Port0[3:0]
C1[15:0] = Port11[3:0], Port10[3:0], Port3[3:0], Port2[3:0]
C2[15:0] = Port13[3:0], Port12[3:0], Port5[3:0], Port4[3:0]
C3[15:0] = Port15[3:0], Port14[3:0], Port7[3:0], Port6[3:0]
Where FI[portN] is the Force IDLE bit for port N and PortN[3:0] is the input port number to be connected to output
port N.
1.7 Built-in Self-Test
The switch has built-in self-test logic that can be used to verify the high-speed circuitry as well as the switch
matrix while operating at full speed. The built-in self-test mode is enabled by setting the built-in self-test enable
(BSTEN) signal HIGH. If the signal BSTLPBK is set HIGH and TESTEN is set LOW, it loops all 16 serial outputs
back to the Data Recovery Unit (DRU) at the serial inputs. An internal Pseudo Random Bit Sequence (PRBS)
generator connected to the switch matrix at port 0. The random data is sent to port 0, passed through the switch
matrix, looped back through the serial interface and returned to the data comparator. If this data matches the correct
pattern, BSTPASS is set HIGH. By configuring port 0 to connect to other ports (ports 1 through 15) through the
switch matrix using the parallel configuration interface, the rest of the serial channels (one port at a time) can be
tested in turn. For example, port 0 can be connected to port 1 by configuring the switch matrix. The PRBS generator
transmits the random data through port 0 to port 1, and the random data is then looped back from port 1 to port 0 and
the data comparator. To test all 16 ports, the user will need to configure the switch matrix 16 times to test all ports.
G52191-0, Rev 4.2
01/05/01
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
Page 11
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
Figure 5: Built-in Self-Test Functional Timing
REFCLK
ADDR[4:0]
BSTRST
BSTPASS
< 10µS
The signal BSTRST is used to reset the PRBS pattern, and there is a comparator that sets the signal
BSTPASS HIGH if the test was successful. The functional timing diagram above shows a typical test sequence.
The PRBS pattern generator can also be tested by itself by setting the control register bit BIST HIGH. This
loops the output of the pattern generator directly back to the comparator circuit. This test will be typically run
before running the tests described above. In this case, the signals BSTEN, BSTRST and BSTPASS will operate
as shown in the Figure 5 above.
The BIST test can be run on no more than two ports at a time, for example: port 0→port 3→port 8→port 0.
Page 12
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
G52191-0, Rev 4.2
01/05/01
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
2.0 Packet Mode
2.1 Overview
In Packet Mode (CMODE=LOW), command words can be sent through the transceiver to the switch chip
requesting connection to one or multiple output channels. Acknowledge (ACK) information will be returned to the
transceiver from the switch allowing the port card to start transmitting data. In this mode of operation, no controller
chip is connected to the switch chip as the switch chip handles all arbitration for connection requests. Details on how
the transceiver operates in Packet Mode mode can be found in the VSC870 data sheet and the applications note 31:
“Design Guide for a Packet Based Switch with Distributed Control”. A picture of a self routing system is shown
below. The minimum packet size in this mode of operation is 4 words or 16 bytes.
Figure 6: Packet Mode System
Port Card
TXFIFO
Trans
Switch Card
RXFIFO
VSC870
Switch
Chip
VSC880
Port Card
TXFIFO
Trans
RXFIFO
VSC870
2.2 Data Encoding Format
The data word and command word formats are described in section 1.0. In this section the header word and
Connection Request (CRQ) word format at the serial input and serial output of the switch are described.
2.2.1 Header word Format on the Serial Data Lines
The header word format as seen at the serial output of the transceiver or switch chip is shown below. Two
overhead bits are added to designate a header word to the receiving chip. The serial data is transmitted with the MSB
first. If multiple headers are sent in a row, the VSC870 will convert all but the first one into IDLEs.
G52191-0, Rev 4.2
01/05/01
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
Page 13
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
33 32
31 30 29 28
27 26 25 24
23 22 21 20
19 18 17 16
15 14 13 12
11 10 09 08
07 06 05 04
03 02 01 00
A A
1 0
0 B B 1
1 0
0 1 1 0
D D D D
19 18 17 16
D D D D
15 14 13 12
D D D D
11 10 09 08
D D D D
07 06 05 04
D D D D
03 02 01 00
1 0 1 0
--------------- Data Payload ----------------
Where:
A[1:0]11=to switch chip, 00=from switch chip
B[1:0]00=Undefined,
01=Flow control channel,
10=Flow control channel,
11=Acknowledge to transceiver
D[19:0]20 bit data payload
2.2.2 CRQ Word Format on the Serial Data Lines to the Switch
The CRQ command word format as seen at the output of the transceiver is shown below. Two overhead bits are
added by the transceiver to designate a CRQ word to the receiving switch chip. The signal ARB, AOA and BRK are
used to control modes of operation in the switch chip. The serial data is transmitted with the MSB first.
33 32
31 30 29 28 27
26 25 24
23 22 21 20
19 18 17 16
15 14 13 12
11 10 09 08
07 06 05 04
03 02 01 00
0 0
0 B B 1 0
1 0
A A B
R O R
C C C C
00 01 02 03
C C C C
04 05 06 07
C C C C
08 09 10 11
C C C C
12 13 14 15
D D D D
03 02 01 00
1 0 1 0
B A K
------ Connection Bits ------
--Data--
Where:
B[1:0]00=Undefined,
01=Flow control channel,
10=Flow control channel,
11=Undefined
ARB1=Multi Queue arbitration
AOA1=Acknowledge on all connections granted, 0=Acknowledge on any connections granted
BRK 1=Break previous connection, 0=Do not break previous connection
C[0:15] Connection request bit map. Set bit high for each output requested
D[3:0] User defined data sent by transmitting port card
2.2.3 CRQ Word Format on the Serial Data Line From the Switch
The CRQ command word format as seen at the output of the switch chip is shown below. Two overhead bits are
added by the switch chip to designate a command word (00) to the transceiver. This word is sent on to the receiving
port card when an ACK is sent to the transmitting port card. The command word contains the current active
connections for this input in the switch chip. The serial data is transmitted with the MSB first.
Page 14
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
G52191-0, Rev 4.2
01/05/01
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
33 32
31 30 29 28 27 26 25
24
23 22 21 20
19 18 17 16
15 14 13 12
11 10 09 08
07 06 05 04
03 02 01 00
0 0
0 B B 1 0 1 0
1 0
B
R
M M M M
00 01 02 03
M M M M
04 05 06 07
M M M M
08 09 10 11
M M M M
12 13 14 15
D D D D
03 02 01 00
1 0 1 0
K
------ Active Connections ------
--Data--
Where:
B[1:0]00=Undefined,
01=Flow control channel,
10=Flow control channel,
11=Acknowledge
BRK1=This is the CRQ word for the next packet. This bit is used to break the current connection.
M[0:15]Current outputs the transmitting channel is connected to
D[3:0] User defined data sent by transmitting port card
2.3 Receiver Operation
In Packet Mode, the receiver looks for connection request (CRQ) words from the transceiver. All data words and
IDLE words are passed on directly to the switch matrix. If BRK is HIGH, the current connection will be broken
before processing the new connection request word. When BRK is LOW, the switch does not break current
connections when making a new request. When AOA is HIGH, the switch will send an ACK only if the current
switch connections match the C[0:15] bit field. When AOA is LOW, an ACK is sent back to the transceiver when any
connection in the C[0:15] bit field is granted. In both cases, a response word is also returned to the transceiver from
the switch. The response word can be embedded into an IDLE word or CRQ word that is sent back to the transceiver.
If the transceiver makes a CRQ that requires a response (i.e., a multicast CRQ), the switch uses the flow control
channel to force an IDLE word into the receiving data stream by forcing the internal ready to receive (RTR) signal
low for one word clock (see the VSC870 data sheet).
The bit field C[0:15] is used to designate the output channels that are to be acted upon for a connection request
operation. To request an output to connect to, set the corresponding bit HIGH. Multiple bits can be set HIGH at the
same time for multicast. The sending port card can include 4 bits of data (D[3:0]) in the CRQ word that will be passed
on to the destination port card. Two example word sequences from the transceiver on the serial interface are shown in
the Figure 7. The two overhead bits (BB) are used for signaling on data words (see the VSC870 date sheet).
G52191-0, Rev 4.2
01/05/01
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
Page 15
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
Figure 7: Packet Transmission Format from Transceiver
Example 2:
Example 1:
11
BB
BB
Header
Start of Packet
D0
D1
11
BB
00
BB
BB
00
00
DN
CRQ
CRQ
CRQ
End of Packet
00
IDLEs
Zero or more IDLEs
11
Header
D0
BB
Header
Start of Packet
D0
CRQ
CRQ
D(N-D)
BB
00
00
DN
CRQ
IDLEs
11
BB
Header
D words before EOP
End of Packet
Zero or more IDLEs
D0
2.4 Arbitration
In Packet Mode, if multiple inputs request a connection to the same output, arbitration is performed. Connection
requests come into the switch chip on each word clock, and the arbitration process takes two word clock cycles.
Arbitration is round-robin with the last connection to an output getting the lowest priority for that output. For
multicast, if BRK is LOW, arbitration will only be performed on the requested connections that are not currently
granted. If a port is in the out of synch state, any connection request to this port will be always granted.
In order to improve bandwidth utilization, a system wide mode of operation can be used where the switch matrix
reconfiguration time is delayed D word clocks after the time arbitration results are determined. This allows the user
logic to receive arbitration results ahead of time so the port cards do not have to block data while waiting for these
results. If the CRQ word is inserted into the current data packet D words before the end of the packet, arbitration
results will be known at the port card just as the first word of the next data packet is ready for transmission, thus
improving bandwidth utilization. The number D is selected based on the round trip delay from the time the port
submits a CRQ until an ACK is received and the FIFO is ready to send a data word. This value of D is a system wide
value and must be used by all port cards. D should be set to a maximum value equal to the round trip delay (typically
8 word clocks).
For Multi Queue connection requests from the transceiver (ARB = 1), the switch chip performs two levels of
arbitration during two word clock cycles. The first level determines which of the requested outputs are available and
holds these outputs. The second level chooses one winner from the available outputs then releases the rest. Because
outputs can be blocked during the first level of arbitration, all Muti Queue CRQ commands are held at the switch chip
and continue to request outputs until a connection is granted or a header word is detected. If a header word is detected
at the transceiver, a repeated sequence of CRQ words is sent to the switch until a connection is granted. The port
number of the granted output is returned to the port card using the two overhead bits (see VSC870 data sheet).
Page 16
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
G52191-0, Rev 4.2
01/05/01
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
2.5 Transmitter Operation
In Packet Mode, the transmitter sends out data words that come from the switch matrix, adding the appropriate
overhead bit information for acknowledges, response bits and flow control. Acknowledges are used to signal the
transceiver that a connection request has been granted (see the VSC870 data sheet). The response bits are used with
the Multi Queue connection request word. The flow control channel is used to pass state information from the
receiving port card to the transmitting port card. The switch redirects the flow control signals to the correct output
using the current switch connection state information. In the case of multicast where there is more than one receiver,
these channels are logically ORed before being sent back to the transmitter. The flow control channel is also used to
send response bits from the switch to the transceiver for multi queue mode (see VSC870 data sheet).
Response words are required by the transceiver in Packet Mode. These response words are simply IDLE words
or CRQ words in the data stream that are going back to the transceiver containing port connection status information.
If the transceiver receives a connection request word that requires a response, it can use the flow control channel to
force an IDLE word into the data stream. When this IDLE arrives at the switch, the switch adds the response data.
2.6 Disconnect Operation
A disconnect can be made to occur automatically after a packet is transmitted through the switch if the packet is
followed by either a CRQ (Connection Request) associated with a new packet, or a null CRQ followed by a null
header word. The CRQ associated with the new packet typically has the BRK bit set. This breaks down the old
connection before it tries to establish the new connection through arbitration. This new connection is made only when
the switch receives the header word. When the old connection is broken, the associated output ports are freed up,
becoming available for new connections. The null CRQ is a CRQ with the BRK bit set, and has no output port
selected. In this case, the switch chip will break down the old connection(s) and will not establish any new
connections. The null CRQ word must be followed by a null (empty) header word. The switch will send IDLE words
to the transceivers which have not established a new connection. During the packet transmission, if the sending link
goes out of synch, the switch will terminate the connection and send an end of packet word (CRQ with the BRK bit
set LOW) to the destination port followed by IDLE words. In this case, the receiving transceiver will receive only one
CRQ instead of the two normally received.
2.7 Flow Control Channel
The VSC880 can support a back pressure mechanism by providing a flow control channel. The flow control
channel is time shared with the signaling between the switch chip and the transceiver for acknowledgment and
response bits. Therefore, it can only guarantee to pass the state information from input pin at the receiving port card
through the switch and to the output pin at the transmitting port card. The main application for this flow control
channel is to prevent the FIFO on the receiving side from overflowing. By using this channel, when the receive FIFO
is almost full, the transmit FIFO will be disabled from sending data. During the time the switch is sending an ACK or
response bits back to the port cards, these flow control bits are dropped by the switch. During a multicast
transmission, the flow control channels are ORed in the switch. If a port is in an out of synch state, no flow control
back pressure is exerted from this output.
G52191-0, Rev 4.2
01/05/01
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
Page 17
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
3.0 Cell Mode
3.1 Overview
In Cell Mode (CMODE = HIGH), a more sophisticated arbitration scheme can be supported by using the
VSC870 and the VSC880 switch in conjunction with a central (user defined) scheduler. In this mode, only fixed
length data packets (cells) can be supported. A cell clock is connected to the switch chip, and the switch chip
distributes the cell clock to all connected transceivers. The transceivers adjust their transmit cell clocks so that all
transceivers send the first word of a cell at such time that it arrives at the switch chip aligned to the switch cell clock
(see serial link operation above). In this mode, messages containing port card queue information are sent to the
central scheduler using an out of band control bus. Arbitration and flow control information are then sent back to the
port cards through the out of band control bus. The scheduler then configures the switch matrix by using the parallel
interface. A picture of a cell based system is shown below. Multiple switch chips can be used in parallel to increase
system bandwidth (see Application Note 32 “Design Guide for a Cell Based Switch with Central Control”).
Figure 8: Cell Based System
Port Card
Queuing
System
Trans
Switch Card
VSC870
Switch
Chip
Scheduler/
Arbiter
VSC880
Port Card
Queuing
System
Trans
VSC870
Out-of-band Control Bus
3.2 Data Encoding Format
The data word and command word formats are described in section 1.0. Command words use the overhead bits
set to 00. Data words can have overhead bits 01, 10 or 11. The user can use these bits for signaling to the receiving
port card. Information such as start of frame and end of frame can be passed through the switch in this manner.
3.3 Receiver Operation
If CMODE is HIGH, the receiver at each port examines the two overhead bits (B[1:0]) of the received word to
determine the word type. If the word is a command word sent from the port card, the switch will respond based on the
type of command specified in the C[4:0] bit field. If an IDLE word arrives at the end of the cell clock period and it
does not have an embedded cell clock, a cell clock error is flagged. If it is a data word, it is sent to the switch fabric
to be routed to its destination along with the user defined overhead bits.
Page 18
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
G52191-0, Rev 4.2
01/05/01
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
3.4 Transmitter Operation
If CMODE is HIGH and the force IDLE register is set LOW, the transmitter sends data words from the switch
fabric. If the force IDLE register is set HIGH, IDLE words are transmitted. At the end of the cell clock period, bits
B[1:0] in all IDLE words are set to 11 to embed the cell clock marker. For data words, user defined overhead bits are
passed on to the destination as is.
3.5 Delaying The Cell Clock
If out-of-band messaging is used between the port cards and the switch card, there will be a phase offset between
the cell clock (CCLK) on the switch card, and the transmit cell clock (RTM/TCLK) on the port card. A cell clock
delay value can be programmed into the control register CDEL[3:0] to set the time the switch is configured after
receiving a cell clock. This adds 1-14 word clocks worth of delay between CCLK input to the switch chip and the cell
clock sent to the transceivers from the switch chip. In this way, the transmit cell clock (RTM/TCLK) on the
transceivers can be aligned to the cell clock at the switch chip (CCLK). For a typical system design where the
transceiver is less then 20” from the switch chip, the default value of 5 can be used. See Application Note 32 for more
details.
G52191-0, Rev 4.2
01/05/01
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
Page 19
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
AC Characteristics
Table 1: LVDS and TTL Outputs
Parameters
Description
Min
Typ
Max
Units
Conditions
TR,TTL
TTL Output Rise Time
2.5
ns
10-90% @ 50pF
TF,TTL
TTL Output Fall Time
2.5
ns
10-90% @ 50pF
TR,LVDS
LVDS Output Rise Time
100
ps
20-80%
TF,LVDS
LVDS Output Fall Time
100
ps
20-80%
Figure 9: Parallel Data Input Timing Diagram
TREFCLK
REFCLK
TINH
TINSU
DATA[15:0], FI[3:0], WEN,
CEN, CCLK,
Table 2: Transmit Data Input Timing Table
Parameter
Description
TREFCLK
Reference (word) clock period
FREFCLK
Reference clock frequency stability
JREFCLK
Reference clock input jitter
Min
Typ
Max
16
Units
ns
100
ppm
7
ps RMS
TINSU
Parallel data setup time with respect to REFCLK
1
ns
TINH
Parallel data hold time with respect to REFCLK
2
ns
TSKEW
REFCLK to REFCLK skew using parallel switch chips
1
ns
Note: Duty cycle for TREFCLK is 50% +/- 10% worst case
Figure 10: Parallel Data Output Timing Diagram
TINT
TINT
INT
Page 20
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
G52191-0, Rev 4.2
01/05/01
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
Table 3: Receive Data Output Timing Table
Parameter
TINT
TRESET
Description
Min
Typ
Max
Units
Interrupt pulse width
15
ns
RESET, RESYNEN pulse width
64
ns
Figure 11: CPU Interface Write Cycle Timing
TH
TWC
TSU
CWEN
TWS
CSEL
ADDR[5:0]
Valid Address
CDATA[7:0]
Valid Data
TWV
TOK
Figure 12: CPU Interface Read Cycle Timing
TD
TSU
TH
CWEN
CSEL
TA
TRZ
ADDR[5:0]
Valid Address
TRD
CDATA[7:0]
Hi-Z
Valid Data
Hi-Z
TRV
Table 4: CPU Interface Timing Table
Parameter
Description
Min
Typ
Max
TOK
CSEL falling edge to valid address
TD
CSEL inactive between read cycles
TSU
CWEN valid to CSEL falling edge
5
ns
TH
CSEL active to CWEN change
5
ns
TWV
Valid data and address during a write
45
ns
TWS
CSEL low time during a write
20
ns
TWC
CSEL cycle time during a write
55
TRV
CSEL active to valid data
15
TRZ
CSEL deactivate to high impedance data
TRD
CSEL active to low impedance data
G52191-0, Rev 4.2
01/05/01
5
Units
10
0
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
ns
ns
ns
45
ns
5
ns
ns
Page 21
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
DC Characteristics
Table 5: LVDS and TTL Inputs and Outputs
Parameters
Description
VOH
Output HIGH voltage (TTL)
VOL
Min
Typ
Max
Units
2.4
—
—
V
Conditions
IOH = -6.0 mA
Output LOW voltage (TTL)
—
—
0.4
V
IOL = +6.0 mA
VOCM
O/P Common Mode Range (LVDS)
1.2
—
2.1
V
At Min ∆VOUT
∆VOUT
Differential Output Voltage (LVDS)
400
—
1000
mV
VICM
I/P Common Mode Range (LVDS)
0.8
—
2.5
V
∆VIN
100Ω across input
At Min ∆VIN
Differential Input Voltage (LVDS)
200
—
1600
mV
—
VIH
Input HIGH voltage (TTL)
2.0
—
VDD+1.0
V
—
VIL
Input LOW voltage (TTL)
0
—
0.8
V
—
IIH
Input HIGH current (TTL)
—
—
500
µA
VIN =2.4V
IIL
Input LOW current (TTL)
- 50
—
—
µA
VIN = 0.4V
500
µA
VOUT=2.4V
IOZB
Bi-directional (TTL) HIGH current
3-State Output OFF
Hot Swap
The LVDS input and output buffers are subject to hot swap events while being connected and disconnected from
the passive backplane. If the input is powered down but still receiving a signal from an output, the input must tolerate
extra input current and power. If the input is powered up but has no input connection, it must go to a valid logic state.
The Table 6 below lists the LVDS I/O parameters that relate to hot swap condition.
Table 6: Hot Swap LVDS I/O Parameters
Parameters
Description
Value
Units
Conditions
ICO
LVDS maximum current delivered per output pin
10
mA
Normal Operation
ICI
LVDS maximum current allowed per input pin
40
mA
VDD = 0V
PCI
LVDS maximum added power per output pin
60
mW
VDD = 0V on VSC870
LOW
—
VCDL
LVDS input default logic state
Input Open
Power Dissipation
Table 7: Power Supply Currents
Parameter
Page 22
Description
(Max)
Units
1000
mA
IDD
Power supply current from VDD, VDDA (VDD, VDDA = 3.3V + 5%)
IDDA
Power supply current from VDDA (VDDA = 3.3V + 5%)
200
mA
IDDX
Power supply current from each serial data quadrant VDDX (VDDX = 3.3V + 5%)
750
mA
IMM
Power supply current from VMM (VMM = 2.5V + 5%)
6800
mA
PDS
Power dissipation (VDD = 3.3V+5%, VMM = 2.5V+5%, all quadrants powered)
30.7
W
PDD
Power dissipation (VDD = 3.3V+5%, VMM = 2.0V+5%, all quadrants powered)
28.1
W
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
G52191-0, Rev 4.2
01/05/01
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
Absolute Maximum Ratings(1)
Power Supply Voltage (VDD) Potential to GND.................................................................................-0.5V to +4V
Power Supply Voltage (VMM) Potential to GND ................................................................................-0.5V to +4V
DC Input Voltage (LVDS inputs) .......................................................................................... -0.5V to VDD + 1.0V
DC Input Voltage (TTL inputs) ......................................................................................................... -0.5V to 5.5V
DC Input Voltage (TTL inputs for CDATA[7:0]).................................................................. -0.5V to VDD + 1.0V
DC Output Voltage (TTL outputs) ........................................................................................ -0.5V to VDD + 1.0V
Output Current (TTL outputs) .................................................................................................................. +/-50mA
Output Current (LVDS outputs) ................................................................................................................+/-50mA
Case Temperature Under Bias ...................................................................................................... -55oC to +125oC
Storage Temperature..................................................................................................................... -65oC to +150oC
NOTE: (1) Caution: Stresses listed under “Absolute Maximum Ratings” may be applied to devices one at a time without causing
permanent damage. Functionality at or exceeding the values listed is not implied. Exposure to these values for extended
periods may affect device reliability.
Recommended Operating Conditions
Power Supply Voltage (VDD)................................................................................................................. +3.3V ± 5 %
Power Supply Voltage (VMM) .............................................................................................. (+2.0V to +2.5V) ±5 %
Extended Commercial Operating Temperature Range(1) (T) ...............................................................0oC to 85oC
NOTE: (1) Lower limit of specification is ambient temperature and upper limit is case temperature.
G52191-0, Rev 4.2
01/05/01
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
Page 23
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
Package Pin Descriptions
Signal
Pin
Signal
Pin
Signal
Pin
Signal
Pin
NC
A01
FI[2]
B15
VDDA
D06
VDD1
G04
VSS
A02
VMM
B16
NC
D07
VDD4
G20
VSS
A03
BSTLPBK
B17
VMM
D08
RXS[14]-
G21
VSS
A04
NC
B18
VDD
D09
VSS
G22
NC
A05
NC
B19
VMM
D10
TXS[14]+
G23
REFCLK
A06
NC
B20
VMM
D11
VDD1
H01
CCLK
A07
VSS
B21
VDD1
D12
TXS[1]-
H02
VSS
A08
VSS
B22
VMM
D13
VDD1
H03
DATA[2]
A09
VSS
B23
VMM
D14
RXS[1]+
H04
DATA[5]
A10
NC
C01
VDD
D15
RXS[14]+
H20
DATA[6]
A11
VSS
C02
VMM
D16
VDD4
H21
DATA[10]
A12
NC
C03
BSTEN
D17
TXS[14]-
H22
DATA[13]
A13
NC
C04
VDD
D18
VDD4
H23
DATA[14]
A14
NC
C05
VSS
D19
RXS[2]-
J01
FI[1]
A15
VSS
C06
NC
D20
VSS
J02
VSS
A16
VMM
C07
VDD4
D21
TXS[2]+
J03
WEN
A17
RESET
C08
NC
D22
VDD1
J04
BSTRST
A18
DATA[0]
C09
VMM
D23
VDD4
J20
NC
A19
DATA[4]
C10
RXS[0]-
E01
TXS[13]+
J21
VSS
A20
DATA[7]
C11
VSS
E02
VSS
J22
VSS
A21
VMM
C12
TXS[0]+
E03
RXS[13]-
J23
VSS
A22
DATA[12]
C13
VDD1
E04
NC
K01
NC
A23
DATA[15]
C14
VDD4
E20
RXS[2]+
K02
VSS
B01
FI[3]
C15
TXS[15]+
E21
VDD1
K03
VSS
B02
CEN
C16
VSS
E22
TXS[2]-
K04
VSS
B03
VMM
C17
RXS[15]-
E23
TXS[13]-
K20
NC
B04
VSS
C18
VSS
F01
VDD4
K21
NC
B05
NC
C19
RXS[0]+
F02
RXS[13]+
K22
NC
B06
VSS
C20
VDD1
F03
VSS
K23
TCLKEN
B07
NC
C21
TXS[0]-
F04
RXS[3]-
L01
VMM
B08
VSS
C22
TXS[15]-
F20
RXS[3]+
L02
DATA[1]
B09
NC
C23
VDD4
F21
NC
L03
DATA[3]
B10
VMM
D01
RXS[15]+
F22
VSS
L04
DATA[8]
B11
NC
D02
VSS
F23
VSS
L20
DATA[9]
B12
VDD1
D03
TXS[1]+
G01
NC
L21
DATA[11]
B13
NC
D04
VSS
G02
RXS[12]+
L22
FI[0]
B14
VSSA
D05
RXS[1]-
G03
RXS[12]-
L23
Page 24
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
G52191-0, Rev 4.2
01/05/01
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
Signal
Pin
Signal
Pin
Signal
Pin
Signal
Pin
VMM
M01
VDD1
M02
RXS[10]-
T23
VDD
Y15
VMM
AB08
VDD2
U01
VDD
Y16
NC
AB09
TXS[3]-
M03
TXS[3]+
M04
TXS[6]-
U02
CDATA[4]
Y17
FACLPBK
AB10
VDD2
U03
VDD
Y18
RESYNEN
AB11
TXS[12]+
M20
RXS[6]+
U04
VSS
Y19
VSCTE
AB12
TXS[12]-
M21
RXS[9]+
U20
VMM
Y20
ADDR[4]
AB13
VDD4
M22
VDD3
U21
TXS[8]+
Y21
CSEL
AB14
VMM
M23
TXS[9]-
U22
NC
Y22
NC
AB15
VMM
N01
VDD3
U23
RXS[8]-
Y23
VMM
AB16
VDD2
N02
TXS[6]+
V01
VMM
AA01
CDATA[2]
AB17
TXS[4]-
N03
VSS
V02
VDD2
AA02
CDATA[5]
AB18
TXS[4]+
N04
RXS[6]-
V03
VMM
AA03
CDATA[7]
AB19
TXS[11]+
N20
VDD2
V04
VSS
AA04
NC
AB20
TXS[11]-
N21
VDD3
V20
VSCIPNC
AA05
VSS
AB21
VDD3
N22
RXS[9]-
V21
VSS
AA06
VSS
AB22
VMM
N23
VSS
V22
VSS
AA07
VSS
AB23
RXS[4]-
P01
TXS[9]+
V23
LOCKDET
AA08
VSS
AC01
RXS[4]+
P02
VSS
W01
NC
AA09
VSS
AC02
VSS
P03
RXS[7]+
W02
SCANIN
AA10
VSS
AC03
NC
P04
VDD2
W03
TESTEN
AA11
VSS
AC04
VSS
P20
TXS[7]-
W04
VMM
AA12
NC
AC05
NC
P21
TXS[8]-
W20
ADDR[3]
AA13
BSTPASS
AC06
RXS[11]+
P22
VDD3
W21
ADDR[0]
AA14
INT
AC07
RXS[11]-
P23
RXS[8]+
W22
NC
AA15
VSS
AC08
NC
R01
VSS
W23
CDATA[1]
AA16
MEN
AC09
RXS[5]+
R02
RXS[7]-
Y01
VSS
AA17
NC
AC10
VDD2
R03
NC
Y02
VSS
AA18
CMODE
AC11
TXS[5]-
R04
TXS[7]+
Y03
NC
AA19
ADDR[5]
AC12
TXS[10]-
R20
VMM
Y04
NC
AA20
ADDR[2]
AC13
VDD3
R21
VSS
Y05
VMM
AA21
ADDR[1]
AC14
RXS[10]+
R22
VDD
Y06
VDD3
AA22
CWEN
AC15
VSS
R23
SCANOUT
Y07
VMM
AA23
VSS
AC16
RXS[5]-
T01
VDD
Y08
NC
AB01
CDATA[0]
AC17
VSS
T02
VDD
Y09
VSS
AB02
CDATA[3]
AC18
TXS[5]+
T03
VMM
Y10
VSS
AB03
CDATA[6]
AC19
VDD2
T04
VMM
Y11
NC
AB04
VSS
AC20
VDD3
T20
VSS
Y12
VSCOPNC
AB05
VSS
AC21
TXS[10]+
T21
VMM
Y13
NC
AB06
VSS
AC22
VSS
T22
VMM
Y14
WCLK
AB07
VSS
AC23
G52191-0, Rev 4.2
01/05/01
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
Page 25
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
Package Information
304 BGA Package
Page 26
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
G52191-0, Rev 4.2
01/05/01
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
Package Thermal Characteristics
The VSC880 is packaged in a thermally enhanced 31mm 304TBGA with an embedded heat sink. The heat sink
surface configurations are shown in the package drawings. With natural convection, the junction to case thermal
resistance is estimated to be 0.45oC/W. The approximate air flow versus thermal resistance relationship is shown in
Table 12.3. Note: The VSC880 is not guaranteed to operate under cold start conditions. If the ambient temperature is
0oC, 15 seconds after power is applied, the case temperature will be at least 30oC, at which point it will be at thermal
equilibrium and ready for operation.
Table 8: Theta Junction-to-Ambient versus Air Velocity
Air Velocity
(LFPM)
Junction-to-Ambient Thermal Resistance
(oC/W)
Low Conductivity
2-Layer Board
High Conductivity
4-Layer Board
0
17.5
13.0
100
15.0
11.0
200
13.0
10.0
400
11.0
9.0
600
10.0
8.0
Ordering Information
The order number for this product is formed by a combination of the device number and package type.
VSC880 xx
Device Type
High Performance 16x16
Serial Crosspoint Switch
Package
TY: 304 BGA
Extended Commerical Temperature: 0°C ambient to +85°C case
Notice
Vitesse Semiconductor Corporation (“Vitesse”) provides this document for informational purposes only. All information in this document, including descriptions of features, functions, performance, technical specifications and availability, is subject to change without notice at any time. Nothing contained in this document shall be construed as extending any warranty or promise, express or implied, that any Vitesse product will be
available as described or will be suitable for or will accomplish any particular task.
Vitesse products are not intended for use in life support appliances, devices or systems. Use of a Vitesse product in such applications without written consent is prohibited.
G52191-0, Rev 4.2
01/05/01
© VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012
Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: [email protected]
Internet: www.vitesse.com
Page 27
VITESSE
SEMICONDUCTOR CORPORATION
Data Sheet
High Performance 16x16
Serial Crosspoint Switch
VSC880
This page left intentionally blank.