WURTH 3020502

Spezifikation für Freigabe / specification for release
Kunde / customer :
Artikelnummer / part number :
Bezeichnung :
description :
3020502
WE-LT Leitende Textildichtung
WE-LT Conductive shielding gasket
DATUM / DATE : 2006-03-21
A Mechanische Abmessungen / dimensions:
Rechteck-Profil / square profile
4
H
1
B
mm
mm
mm
5,0
2,0
1000,0
2
H
L
1
B
H
L
B
3
2
#BEZUG!
B Elektrische Eigenschaften / electrical properties:
Eigenschaften / properties
Einfügungsdämpfung:maximum /
insertion loss:maximum
≥ 80 dB / 100 MHz (basierend auf / based on MIL-STD-225)
≥ 75 dB / 1 GHz
Oberflächenwiderstand /
Surface resistivity
< 0,08 Ohm
Nicht brennbar - selbstverlöschend / non-inflammable - self-extinguishing
D Testbedingungen / test conditions:
E Eigenschaften / general specifications:
Luftfeuchtigkeit / humidity:
33%
Umgebungstemperatur / temperature:
+20°C
Lagertemperatur / storage temperature:
-25°C - +85°C
Betriebstemperatur / operating temperature:
-25°C - +85°C
F Werkstoffe & Zulassungen / material & approvals:
No.
Generic Name
Grade Name
UL File No.
Flame Class
1
Metallized Fiber
SUI-13-#FR
E178902
UL94VTM-0
130 mic.
UEM-55(CY)
E188467
94V-0
Max 34,74 mm;
min. 0,74 mm
Rayon Paper with acrylic Adhesive
750F
E125972
UL94VTM-0
0,16 mm
Reactive Polyurethane Hotmelt Adhesive
HI-BON No. 4832
none
none
50 mic.
SSt
Version 2
06-03-21
SSt
Version 1
05-11-09
Name
Änderung / modification
Datum / date
2
Polyether Urethane Foam
3
4
Freigabe erteilt / general release:
..................................................................................
Datum / date
..................................................................................
Geprüft / checked
Thickness
Kunde / customer
...............................................................................
Unterschrift / signature
Würth Elektronik
...............................................................................
Kontrolliert / approved
This electronic component is designed and developed with the intention for use in general electronics equipments. Before incorporating the components into any equipments in the field such as aerospace,
aviation, nuclear control, submarine, transportation, (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc. where higher safety and
reliability are especially required or if there is possibility of direct damage or injury to human body. In addition, even electronic component in general electronic equipments, when used in electrical circuits that
require high safety, reliability functions or performance, the sufficient reliability evaluation-check for the safety must be performed before use. It is essential to give consideration when to install a protective
circuit at the design stage.
Würth Elektronik eiSos GmbH & Co. KG
D-74638 Waldenburg · Max-Eyth-Strasse 1 - 3 · Germany · Telefon (+49) (0) 7942 - 945 - 0 · Telefax (+49) (0) 7942 - 945 - 400
http://www.we-online.com
SEITE 1 VON 1