ALLEN-BRADLEY 440N

Interlock Switches
Non contact Switches
Ferrocode
Specifications (continued)
Utilization Category (AC)
4A/250V AC/1000VA at COSϕ=1
Max Switched DC Current/Volt 2A/30V DC/60W
Min Switched DC Current/Volt 10mA/10V
Description
Max Output Fuse
5A quick acting
Indication
Green = Power ON
Green = Output closed
Max Drop Out Time
<50mS
Impulse withstand Voltage
2500V
Operating Temperature
-10°C to +55°C (14°F to 131°F)
Contamination Level
3
Humidity
90% RH
Degree of Enclosure
Protection
IP40 DIN 0470
Terminal Isolation
IP20 DIN 0470
A two-channel system, the Ferrocode setup consists of an actuator
and a separate safety switch head that is connected to a monitoring
control unit. The Ferrocode uses electromagnetic coding, which
provides a higher level of security over magnetic coding systems. To
further prevent possible override of the system, both sensor and
actuator are supplied with tamper-resistant mounting hardware.
Max Conductor Size
1 x 2.5mm2 (14 AWG) stranded with
sleeve stripped 8mm,1 x 4mm2
(14AWG) solid conductor
Terminals
The absence of moving parts and direct physical contact between
sensor and actuator eliminate mechanical wear.
Plus-minus terminal screws M3.5
Box terminal with wire protection
Weight 24V DC unit
110/230V unit
314g (0.69lbs)
530g (1.17lbs)
A Ferrocode sensor may be used without the control unit for low
power/low risk applications. However, risks should be thoroughly
evaluated prior to application of this method.
Material & Colour
Red polycarbonate
The control unit should be used when monitoring and checking of
the circuit is required. Up to 6 Ferrocode switches can be interfaced
with the 110/230V control unit and up to 15 Ferrocode switches
with the 24V version. A control unit may also be used in conjunction
with electromechanical safety devices such as limit switches, gate
interlocks and emergency stops with two contacts, 1 N.O. & 1 N.C.
Housing
16 way D = 120 H = 73 W = 45.5
Installation Group
C in accordance with VDE 0110
Fixing Details
35mm DIN rail
Switching Head
Power Supply
24V DC +/– 15%
Power Consumption
<1VA
Internal Fuse
1A output fuse
Safety Distance
ON = 7mm, OFF = 9mm
Features
Aux. Distance
ON = 9mm, OFF = 14mm
• Electro-magnetic tamper resistant coding
• Interfaces directly to a safety relay control unit
Outputs
1 N.O. & 1 N.C.
Utilization Category (AC)
0.5A/120V AC/60VA at COSϕ =1
Max Switched DC Current/Volt 1A/28V DC/28W
Specifications
Standards
Category
Min Switched DC Current/Volt 10mA/10V
EN954-1, ISO13849-1, IEC/EN602041, NFPA79, EN1088, ISO14119,
IEC60947-5-1, ANSI B11.19,
AS4024.1
Max Output Fuse
1A quick acting
Indication
LED 1
Impulse withstand Voltage
2500V
Cat. 3 per EN954-1 (Sensors with
controller)
Operating Temperature
-10°C to +55°C (14°F to 131°F)
Contamination Level
3
Green 1 = Guard closed
Approvals
CE marked for all applicable directives
and cULus
Humidity
90% RH
Power Supply
24V AC/DC or 110/230V AC
Degree of Protection
IP67 (NEMA 6P)
Power Consumption
<6VA
X1-X2 Contactor Monitor
Loop
Normally closed contactor loop
Weight (not including cable)
Switch 30g (0.07lbs)
Actuator 40g (0.09lbs)
Safety Inputs
1 N.O. & 1 N.C. from Ferrocode head
Internal Fuse
500 mAT replaceable supply fuse
Internal Switches
Mains selector switch
Relay Output
2 N.O. & 1 N.C. TÜV approved
3-68
Material & Colour
Red moulded ABS plastic
Fixing Details
M4
Cable
0.2 mm2 (24AWG) 6 wire; Braided
PVC Jacket OD 6mm (0.23in)
Interlock Switches
Non contact Switches
Ferrocode
Product Selection
Type
Supply Voltage
Safety Contacts
Auxiliary
Contacts
Connection
Housing
Catalogue Number
2 N.O.
1 N.C.
Terminals
45mm Wide
Polycarbonate
440N-C02068
24V AC/DC
Control Unit
110V 230V AC
2m Cable
Switch & Actuator
24V AC/DC
1 N.C. & 1 N.O.
440N-C02067
6m Cable
None
440N-C02070
Red, ABS Plastic
8m Cable
10m Cable
440N-C02078
440N-C02076
440N-C02079
Note: Contacts are described with the guard door close, that is, actuator in place. Switch is shipped complete with actuator.
Accessories
Description
Page Number
Catalogue Number
Actuator
—
440N-A02071
Fuse, 500mA
14-6
440R-A31562
Approximate Dimensions—mm (inches)
Dimensions are not intended to be used for installation purposes.
Switch
Actuator
7 (0.28)
Control Unit
7 (0.28)
4.5 (0.18)
4.5 (0.18)
45.5
(1.79)
35 (1.38)
DIN Rail Mounting
73 (2.87)
73 (2.87)
73 (2.87)
=
82 (3.23)
41 (1.61)
54 (2.13)
84 (3.31)
=
120 (4.72)
7 (0.28)
16
(0.63)
= =
11
4
4 (0.43) (0.16)
(0.16)
19 (0.75)
19 (0.75)
4.5
(0.18)
19 (0.75)
4.5
(0.18)
Block
A1
A2
F1
110/230
X1
24V DC
S13
S14
S21
S22
X2 Red (Black)
(White) (Green) (Yellow) 13 23
K1
K2 K2
K3
~
K3
31
K3
VR1
Logic
Power
K2
K1
K2
K1
K2
K3
Logic
K3
Output
Blue
14 24
32
3-69
Interlock Switches
Non contact Switches
Ferrocode
Typical Wiring Diagrams
+24V DC
Reset
L1 L2 L3
Sensor 1
Actuator
Sensor 2
Actuator
Sensor 3
Actuator
B1 S13 S21 A1 13 23 31 X1
K1
Ferrocode
K2
B2 S14 S22 A2 14 24 32 X2
Aux
K1 K2
Ground
Multiple Sensor Input, Manual Reset,
Dual-Channel Output, Monitored Output
L1
L1 L2 L3
B1 S13 S21 A1 13
K1
Sensor 1
Actuator
23 31 X1
Ferrocode
K2
B2 S14 S22 A2 14 24
K1
K2
32 X2
Aux
M
N
Single Sensor Input, Automatic Reset,
Dual-Channel Output, Monitored Output
Ferrocode Sensor
Red
Blue
+
24V DC
Supply
–
Black
Safety
N.C.
White
Yellow
Safety
N.O.
Green
3-70
Note: External Fuse is recommended
when switch is not powered by a
Ferrocode control unit. Recommend
using 24V DC or 110V AC, 300mA fuse.
M
Interlock Switches
Non contact Switches
Ferrocode
Typical Application Details
On presenting the actuator to the
switch, the high-intensity
electromagnetic field together with a
resonant frequency signal causes the
contacts to close. On removing the
actuator (opening the door) the safety
contacts open, isolating the machine.
The switch can not be overridden by
magnets, tools, etc.
Safety contact operating distance:
make 7mm, break 9mm
Auxiliary contact operating distance:
make 9mm, break 14mm
Application Details
Actuator Spacing
Actuator Approach Directions
>25mm
Switch
Switch
Actuator
Actuator
On hinged doors, install switch at the opening edge.
Where 2 switches are mounted adjacent, they should
be no closer than 25mm. Recommend a 2mm spacing
between switch and actuator.
Typical Configurations
The Ferrocode switch can
be used without a control
unit for low risk/low power
applications.
Wigan WN2 4HR
Six Ferrocode switches can be used with one control
unit for high risk applications. Connect the N.C.
contacts (black and white wires) in series and the N.O.
contacts (green and yellow wires) in parallel.
A1 A2 X1 X2 B1 B2 S13 S14
0942 55166
SUPPLY
Red
Blue
Black
White
Wigan WN2 4HR
Wigan WN2 4HR
Wigan WN2 4HR
Wigan WN2 4HR
Wigan WN2 4HR
Wigan WN2 4HR
0942 55166
0942 55166
0942 55166
0942 55166
0942 55166
0942 55166
One Ferrocode switch
used with a control unit
provides a higher
integrity system.
A1 A2 X1 X2 B1 B2 S13 S14
SUPPLY
Red
SEE SIDE FOR SUPPLY
Ferrocode
Ferrocode
Safety
Switch
Actuator
1A 28Vdc
0.5A 120Vac
IP 67
Wigan WN2 4HR
0942 55166
Made in
England
FERROCODE
Control Unit
TAMPER PROOF
SAFETY SYSTEM
pr EN 1088
EN 60204 pt.1
AUXILIARY
SAFETY 1
!
ISOLATE BEFORE
REMOVING COVER
SAFETY 2
Green
Yellow
31 32 13 14 23 24 S21S22
Made in
England
Black
White
Wigan WN2 4HR
0942 55166
Made in the EC
POWER
OUTPUT
Blue
SEE SIDE FOR SUPPLY
Made in the EC
Ferrocode
Ferrocode
Ferrocode
Ferrocode
Ferrocode
Ferrocode
Safety
Switch
Safety
Switch
Safety
Switch
Safety
Switch
Safety
Switch
Safety
Switch
1A 28Vdc
0.5A 120Vac
IP 67
1A 28Vdc
0.5A 120Vac
IP 67
1A 28Vdc
0.5A 120Vac
IP 67
1A 28Vdc
0.5A 120Vac
IP 67
1A 28Vdc
0.5A 120Vac
IP 67
1A 28Vdc
0.5A 120Vac
IP 67
Made in
England
Made in
England
Made in
England
Made in
England
Made in
England
Made in
England
FERROCODE
Control Unit
TAMPER PROOF
SAFETY SYSTEM
pr EN 1088
EN 60204 pt.1
AUXILIARY
SAFETY 1
!
POWER
OUTPUT
ISOLATE BEFORE
REMOVING COVER
SAFETY 2
Green
Yellow
31 32 13 14 23 24 S21S22
Ferrocode
Ferrocode
Safety
Switch
Actuator
1A 28Vdc
0.5A 120Vac
IP 67
Wigan WN2 4HR
0942 55166
Made in
England
Made in
England
Typical Applications
Sliding Guard
Removable Guard
Hinged Guard
Note: Removable guards using Non contact
switches may require two switches, one at either
side of the guard, or the use of a flap to prevent
initial lifting of the non-interlocked edge.