ASM-SENSOR 3490

ANALOG MW HiTESTER 3490
Field measuring instruments
3-range
INSULATION & CONTINUITY
3Ω range, 200mA
Bright LED
OPTION
TEST LEAD WITH
REMOTE CONTROL SWITCH 9788
Insulation Testing in 3 Easy Steps
Flip the Cover, Select Range & Test
Check for
Live Circuits
2
Check the
Battery Status
BATT : Hi BATT : Lo BATT : Dead
Luminous Scale
The LIVE CIRCUIT LED will light up
in red whenever the voltage exceeds
20V AC between the LINE and EARTH
terminals, and when at least 20V DC is
still remaining during the auto discharge.
Be well-informed about the condition of your batteries. Green signals that the battery level is sufficiently
high, and red warns of low battery power. Replace the
batteries before the LED turns completely off.
General Specifications
Power source
Continuous operating time
Auto Power Save
Operating Temperature & Humidity
Rated power voltage: 1.5 VDC × 4, LR6 alkaline battery × 4
Approx. 20 hours (at 500V range, no load)
Approx. 15 minutes
0 to 40°C (32 to 104°F), 90%RH or lower (non-condensating)
40 to 50°C (104 to 122°F), at 50°C and below relative with linear decrease up to 50%RH
0 to 50°C (32 to 122°F), 90%RH or lower (non condensating)
Storage Temperature & Humidity
600 VAC, Measurement Category Ш, Anticipated Transient Overvoltage: 6000V
Maximum rated voltage to earth
5312 VAC, 50/60Hz, Measurement terminals - electrical enclosure, current sensitivity 1 mA
Dielectric strength
Safety EN61010 EMC EN61326
Standards
On concrete: 1m/1 time
Drop Proof
Dimensions (excluding protrusions) Approx. 159W × 162H × 48D mm (6.26"W × 6.38"H × 1.89"D)
Approx. 550g (19.4 oz.) (including battery, not including test lead)
Mass
9787 Test Lead, Instruction manual, Shoulder strap, LR6 alkaline battery × 4
Accessories
o 3490 specifications
Guaranteed for one year at 23˚C±5˚C (73˚F±9˚F) and 90% RH
250 V DC
500 V DC
1000 V DC
100 MW
4000 MW
1 MW
50 MW
0.05 to 50 MW
2 to 1000 MW
±5% of indicated value
0.01 to 0.05 MW
0.5 to 2 MW
50 to 100 MW
1000 to 4000 MW
±10% of indicated value
1 to 1.2 times of rated output voltage
Rated output voltage
Effective maximum indicated value
Center scale value
Insulation
Resistance
Measurement
Resistance
Measurement
AC voltage
Measurement
1st effective
measuring range
2nd effective
measuring range
Open circuit voltage
Lower limit measurement resistance value
to be maintained reted output voltage
Rated current
Overload protection
Ranges
Center scale value
Accuracy
Open-circuit voltage
Measuring current
Overload protection
Measuring range
Accuracy
Input resistance
Overload protection
Accessories
Options
TEST LEAD 9787 (1.2m)
TEST LEAD WITH
REMOTE CONTROL SWITCH
9788 (1.2m)
0.25 MW
TEST PROBE 9294
(1.2m)
1904 Shanghai Times Square Office, 93 Huai Hai Zhong Road
Shanghai, P.R.China POSTCODE: 200021
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360
E-mail: [email protected]
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: [email protected]
1 MW
1mA (Tolerance: 1 to 1.2 times of the rating value)
1200V AC (10 sec.)
3W
30W
1.5W
15W
±0.09W
±0.9W
4.1 to 6.9 V
200mA DC or more
20mA DC or more
720V AC (10 sec., by Fuse)
0 to 600 V (50/60 Hz)
±5% of maximum scale value
100 kW or more (50/60Hz)
1200V AC (10 sec.)
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: [email protected]
0.5 MW
CONNECTION CORD 9257
(1.3m)
BREAKER PIN 9288
(for Model 9294)
90mm(3.54")
DISTRIBUTED BY
Beijing Office :
A-2602 Freetown, 58 Dong San Huan Nan Road
Beijing, P.R.China POSTCODE: 100022
TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090
E-mail: [email protected]
Guangzhou Office :
Room 303, Profit Plaza, No.76, West Huangpu Road
Guangzhou, P.R.China POSTCODE: 510623
TEL +86-20-38392673/2676 FAX +86-20-38392679
E-mail: [email protected]
All information correct as of June 27, 2008. All specifications are subject to change without notice.
3490E1-86E
Printed in Japan