AZETTLER AZ420

AZ420
MINIATURE GENERAL
PURPOSE RELAY
FEATURES
•
•
•
•
•
•
•
•
•
•
Rugged construction for high reliability
Life expectancy greater than 100 million operations
DC coils to 115 V
Power consumption as low as 25 mW per pole available
Current sensitive and voltage sensitive coils available
Round core and large coil volume provide greater pull force
Up to 6 poles in less than one cubic inch
Dry circuit to 5 Amp contacts
Printed circuit or solder/plug-in terminals
Balanced spring-held armature allows dependable
operation in any position
• Sealed version available (2 and 4 pole)
• UL, CUR file E43203; VDE 0110 Gr. A
GENERAL DATA
Life Expectancy
Mechanical
Electrical
Minimum operations
500 million
See typical contact life expectancy table
Operate Time
See typical operate and release time
diagram
CONTACTS
Arrangement
Ratings
Release Time
DPDT (2 Form C)
4PDT (4 Form C)
6PDT (6 Form C)
See typical operate and release time
diagram
Capacitance (typical)
See contact data table under relay ordering data
UL Rating: See table for UL approved contact
ratings
Contact to contact: 2 pF
Contact to coil: 2 pF
Contact to frame: 30 pF
Bounce (typical)
At 10 mA contact current
3 ms at nominal coil voltage
Dielectric Strength
(at sea level)
1500 Vrms contact to coil
1000 Vrms all other points
Insulation
Resistance
1000 megohms min. at 25°C
500 VDC 50% RH
Dropout
Greater than 5% of nominal coil voltage
Ambient Temperature
Operating
Standard
At nominal coil voltage
2 and 4 pole type:
-55°C (-67°F) to 80°C (176°F)
6 pole type:
-55°C (-67°F) to 65°C (149°F)
-55°C (-67°F) to 95°C (203°F)
-55°C (-67°F) to 105°C (220°F)
Material
See contact data table under relay ordering data
Resistance
< 50 milliohms initially
COIL
Power
At Pickup Voltage
(typical)
Max. Continuous
Dissipation
Temperature Rise
Standard
Sensitive
Temperature
Standard: 450 mW, 2 or 4 pole
Sensitive: 80 mW, 2 pole
180 mW, 4 pole
(25 mW per pole available)
2.6 W at 20°C (68°F) ambient
2.0 W at 40°C (105°F) ambient
23°C (41°F) at nominal coil voltage,2 or 4 pole
40°C (72°F) at nominal coil voltage, 6 pole
5°C (9°F) at nominal coil voltage, 2 pole
10°C (18°F) at nominal coil voltage, 4 pole
Max. 105°C (221°F)
NOTES
1. Other coil resistances and sensitivities are available upon request.
2. All values at 20°C (68°F).
3. Bifurcated crossbar, fine silver/gold plated contacts are recommended
for dry circuit switching.
4. Epoxy sealed versions for automatic wave soldering and cleaning are
available.
5. Specifications subject to change without notice.
Sensitive
Storage
Vibration
0.062" DA at 5–55 Hz
Shock
20 g
Enclosure
Polycarbonate
Terminals
Plug-in: gold or tin plated copper alloy
PC: tin plated copper alloy
Max. Solder Temp.
270°C (518°F)
Max. Solder Time
5 seconds
Max. Solvent Temp.
80°C (176°F)
Max. Immersion Time
30 Seconds
Weight
23 to 35 grams
8/21/08W
AZ420
RELAY ORDERING DATA — TWO POLE
STANDARD DC VOLTAGE VERSION
COIL SPECIFICATIONS
Nominal
Max.
Coil
Coil
Continuous Resistance
VDC
VDC
± 10%
3
5
14
ORDER NUMBER
Must
Operate
VDC
2.25
Unsealed
Plug-in/Solder
Terminals
PC Terminals
AZ420–21–*–
AZ428–21–*–
Sealed
PC Terminals
AZ2428–21–*–
6
10
52
4.5
AZ420–15–*–
AZ428–15–*–
AZ2428–15–*–
12
19
185
9.0
AZ420–1011–*–
AZ428–1011–*–
AZ2428–1011–*–
18
29
430
13.0
AZ420–80–*–
AZ428–80–*–
AZ2428–80–*–
20
34
600
16.0
AZ420–08–*–
AZ428–08–*–
AZ2428–08–*–
24
37
700
18.0
AZ420–70–*–
AZ428–70–*–
AZ2428–70–*–
26
44
1,000
21.0
AZ420–07–*–
AZ428–07–*–
AZ2428–07–*–
48
70
2,500
36.0
AZ420–56–*–
AZ428–56–*–
AZ2428–56–*–
72
105
5,800
54.0
AZ420–40–*–
AZ428–40–*–
AZ2428–40–*–
115
170
15,000
86.0
AZ420–035–*–
AZ428–035–*–
AZ2428–035–*–
B. SENSITIVE DC VOLTAGE VERSION (Pickup 100 mW)
COIL SPECIFICATIONS
Nominal
Max.
Coil
Coil
Continuous Resistance
VDC
VDC
± 10%
3
10
50
ORDER NUMBER
Must
Operate
VDC
2.25
Unsealed
Plug-in/Solder
Terminals
PC Terminals
AZ420–V15–*–
AZ428–V15–*–
Sealed
PC Terminals
AZ2428–V15–*–
6
20
200
4.5
AZ420–V10–*–
AZ428–V10–*–
AZ2428–V10–*–
12
41
800
9.0
AZ420–V70–*–
AZ428–V70–*–
AZ2428–V70–*–
24
81
3,200
18.0
AZ420–V50–*–
AZ428–V50–*–
AZ2428–V50–*–
48
104
13,000
36.0
AZ420–V04–*–
AZ428–V04–*–
AZ2428–V04–*–
C. SENSITIVE DC CURRENT VERSION (Pickup 85 mW)
COIL SPECIFICATIONS
Nominal
Max.
Coil
Coil
Continuous Resistance
VDC
VDC
± 10%
12
44
1,000
18
70
29
44
51
ORDER NUMBER
Must
Operate
(mA)
8.5
Unsealed
Plug-in/Solder
Terminals
PC Terminals
AZ420–C07–*–
AZ428–C07–*–
Sealed
PC Terminals
AZ2428–C07–*–
2,500
5.4
AZ420–C56–*–
AZ428–C56–*–
AZ2428–C56–*–
102
5,000
4.1
AZ420–C045–*–
AZ428–C045–*–
AZ2428–C045–*–
144
10,000
3.1
AZ420–C408–*–
AZ428–C408–*–
AZ2428–C408–*–
170
15,000
2.4
AZ420–C035–*–
AZ428–C035–*–
AZ2428–C035–*–
*ORDERING
PROCEDURE:
To specify an AZ 420 series
relay, combine the basic part
number found in the Order
Number section with a
contact code found in the
Contact Data Table.
EXAMPLE:
AZ420–21–40LUS:
A. Basic number: AZ420–21–
indicates two pole, plug-in/
solder terminals, standard
coil, 3 VDC, 14 ohms.
B. Contact code: 40LUS
indicates bifurcated crossbar
fine silver/gold plated
contacts, Form C, UL and
CUR approved.
CONTACT DATA TABLE
Contact
Material
Maximum
Switched
Load
Switching
Range at 28
VDC or 115
VAC (Typical)
Contact
Material
Maximum
Switched
Load
Switching
Range at 28
VDC or 115
VAC (Typical)
40LUS
4LUS
Bifurcated Max. Power:
crossbar
56 W or
contact
230 VA
Single
crossbar
contact
Fine silver/ Max. current: Dry circuit
gold plated 2 Amps
to 2 Amps
Moveable: Max. current 1 mA to
fine silver/ 2 Amps
2 Amps
gold plated
Max. voltage
150† VDC or
300 VAC
Max. voltage:
150† VDC or
300 VAC
Contact
Material
Maximum
Switched
Load
Switching
Range at 28
VDC or 115
VAC (Typical)
4HUS
Max. power
100 W or
350 VA
Single
crossbar
contact
Moveable:
silver cadmium
oxide/gold
plated
Max. power
225 W or
870 VA
Max. current: 100 mA to
5 Amps
5 Amps
Max. voltage:
150† VDC or
300 VAC
† If switching voltage is greater than 30 VDC, special precautions must be taken. Contact the factory.
08/21/08W
AZ420
RELAY ORDERING DATA — FOUR POLE
A. STANDARD DC VOLTAGE VERSION
COIL SPECIFICATIONS
Nominal
Max.
Coil
Coil
Continuous Resistance
VDC
VDC
± 10%
3
5
14
ORDER NUMBER
Must
Operate
VDC
2.25
Unsealed
Plug-in/Solder
Terminals
PC Terminals
AZ421–21–*—
AZ429–21–*—
Sealed
PC Terminals
AZ2429–21–*—
6
10
52
4.5
AZ421–15–*—
AZ429–15–*—
AZ2429–15–*—
12
19
185
9.0
AZ421–1011–*—
AZ429–1011–*—
AZ2429–1011–*—
18
29
430
13.0
AZ421–80–*—
AZ429–80–*—
AZ2429–80–*—
20
34
600
16.0
AZ421–08–*—
AZ429–08–*—
AZ2429–08–*—
24
37
700
18.0
AZ421–70–*—
AZ429–70–*—
AZ2429–70–*—
26
44
1,000
21.0
AZ421–07–*—
AZ429–07–*—
AZ2429–07–*—
48
70
2,500
36.0
AZ421–56–*—
AZ429–56–*—
AZ2429–56–*—
72
105
5,800
54.0
AZ421–40–*—
AZ429–40–*—
AZ2429–40–*—
115
170
15,000
86.0
AZ421–035–*—
AZ429–035–*—
AZ2429–035–*—
COIL SPECIFICATIONS
ORDER NUMBER
Must
Operate
VDC
2.25
110
To specify an AZ 421 series
relay, combine the basic part
number found in the Order
Number section with a contact code found in the Contact
Data Table.
EXAMPLE:
AZ421–21–10LUS:
B. SENSITIVE DC VOLTAGE VERSION (Pickup 180 mW)
Nominal
Max.
Coil
Coil
Continuous Resistance
VDC
VDC
± 10%
3
8
30
*ORDERING
PROCEDURE:
Unsealed
Plug-in/Solder
Terminals
PC Terminals
AZ421–V18–*—
AZ429–V18–*—
Sealed
PC Terminals
AZ2429–V18–*—
4.5
AZ421–V12–*—
AZ429–V12–*—
AZ2429–V12–*—
6
15
12
30
450
9.0
AZ421–V80–*—
AZ429–V80–*—
AZ2429–V80–*—
24
61
1,800
18.0
AZ421–V05–*—
AZ429–V05–*—
AZ2429–V05–*—
48
124
7,500
36.0
AZ421–V04–*—
AZ429–V04–*—
AZ2429–V04–*—
A. Basic number: AZ421–21–
indicates four pole, plugin/
solder terminals, standard
coil, 3 VDC, 14 ohms.
B. Contact code: 10LUS
indicates bifurcated crossbar
fine silver/gold plated
contacts, Form C, UL and
CUR approved.
C. SENSITIVE DC CURRENT VERSION (Pickup 85 mW)
COIL SPECIFICATIONS
Nominal
Max.
Coil
Coil
Continuous Resistance
VDC
VDC
± 10%
19
44
1,000
ORDER NUMBER
Must
Operate
(mA)
13.0
Unsealed
Plug-in/Solder
Terminals
PC Terminals
AZ421–C07–*—
AZ429–C07–*—
Sealed
PC Terminals
AZ2429–C07–*—
30
70
2,500
8.3
AZ421–C56–*—
AZ429–C56–*—
AZ2429–C56–*—
44
102
5,000
6.2
AZ421–C045–*—
AZ429–C045–*—
AZ2429–C045–*—
64
144
10,000
4.5
AZ421–C408–*—
AZ429–C408–*—
AZ2429–C408–*—
75
170
15,000
3.5
AZ421–C035–*—
AZ429–C035–*—
AZ2429–C035–*—
CONTACT DATA TABLE
Contact
Material
Maximum
Switched
Load
Switching
Range at 28
VDC or 115
VAC (Typical)
Contact
Material
Maximum
Switched
Load
Switching
Range at 28
VDC or 115
VAC (Typical)
10LUS
1LUS
Bifurcated Max. Power:
crossbar
56 W or
contact
230 VA
Single
crossbar
contact
Fine silver/ Max. current: Dry circuit
gold plated 2 Amps
to 2 Amps
Moveable: Max. current 1 mA to
fine silver/ 2 Amps
2 Amps
gold plated
Max. voltage
150† VDC or
300 VAC
Max. voltage:
150† VDC or
300 VAC
Contact
Material
Maximum
Switched
Load
Switching
Range at 28
VDC or 115
VAC (Typical)
1HUS
Max. power
100 W or
350 VA
Single
crossbar
contact
Moveable:
silver cadmium
oxide/gold
plated
Max. power
225 W or
870 VA
Max. current: 100 mA to
5 Amps
5 Amps
Max. voltage:
150† VDC or
300 VAC
† If switching voltage is greater than 30 VDC, special precautions must be taken. Contact the factory.
8/21/08W
AZ420
RELAY ORDERING DATA — SIX POLE
CONTACT DATA TABLE
A. STANDARD DC COIL VOLTAGE VERSION
COIL SPECIFICATIONS
ORDER NUMBER
Nominal
Max.
Coil
Must
Coil
Continuous Resistance Operate
VDC
VDC
± 10%
VDC
3
4.5
11
2.25
Plug-in/
Solder
Terminals
AZ431–22–*—
PC Terminals
Contact
Material
Maximum
Switched
Load
(Typical)
AZ439–22–*—
10LUS
6
7
25
4.5
AZ431–18–*—
AZ439–18–*—
12
14
90
9.0
AZ431–13–*—
AZ439–13–*—
Bifurcated
crossbar contact
Max. Power:
56 W or 230 VA
18
22
230
13.0
AZ431–10–*—
AZ439–10–*—
20
26
360
16.0
AZ431–09–*—
AZ439–09–*—
Fine silver/
gold plated
Max. current:
2 Amps
24
29
430
18.0
AZ431–80–*—
AZ439–80–*—
26
34
600
21.0
AZ431–08–*—
AZ439–08–*—
1LUS *
48
59
1,800
36.0
AZ431–06–*—
AZ439–06–*—
72
83
3,600
54.0
AZ431–05–*—
AZ439–05–*—
Single
crossbar contact
Max. power:
100 W or 350 VA
115
130
9,000
86.0
AZ431–04–*—
AZ439–04–*—
Moveable:
fine silver/
gold plated
Max. current:
2 Amps
COIL SPECIFICATIONS
Dry circuit
to 2 Amps
Max. voltage: 150†
VDC or 300 VAC
1 mA to
2 Amps
Max. voltage: 150†
VDC or 300 VAC
B. SENSITIVE DC VOLTAGE VERSION (Pickup 250 mW)
ORDER NUMBER
Nominal
Max.
Coil
Must
Coil
Continuous Resistance Operate
VDC
VDC
± 10%
VDC
3
6
20
2.25
Switching
Range at 28
VDC or 115
VAC
Plug-in/
Solder
Terminals
AZ431–V19–*—
AZ439–V19–*—
PC Terminals
1LUS **
Single contact
button
Max. power:
56 W or 230 VA
Fine silver/
gold plated
Max. current:
2 Amps
Low level
to 2 Amps
6
13
80
4.5
AZ431–V13–*—
AZ439–V13–*—
12
26
320
9.0
AZ431–V09–*—
AZ439–V09–*—
24
50
1,200
18.0
AZ431–V60–*—
AZ439–V60–*—
1HUS *
48
68
5,200
36.0
AZ431–V045–*—
AZ439–V045–*—
Single
crossbar contact
Max. power:
225 W or 870 VA
Moveable:
silver cadmium
oxide/gold
plated
Max. current:
100 mA to
5 Amps
5 Amps
Max. voltage: 150†
VDC or 300 VAC
C. SENSITIVE DC CURRENT VERSION (Pickup 250 mW)
COIL SPECIFICATIONS
ORDER NUMBER
Nominal
Max.
Coil
Must
Coil
Continuous Resistance Operate
VDC
VDC
± 10%
(mA)
23
44
1,000
16.0
Plug-in/
Solder
Terminals
AZ431–C07–*—
AZ439–C07–*—
PC Terminals
36
70
2,500
10.0
AZ431–C56–*—
AZ439–C56–*—
51
102
5,000
7.2
AZ431–C045–*—
AZ439–C045–*—
71
144
10,000
5.0
AZ431–C408–*—
AZ439–C408–*—
90
170
15,000
4.2
AZ431–C035–*—
AZ439–C035–*—
*ORDERING PROCEDURE:
To specify an AZ 431 series relay, combine the basic
part number found in the Order Number section with a
contact code found in the Contact Data Table.
Max. voltage: 150†
VDC or 300 VAC
1HUS **
Single contact
button
Max. power:
140 W or 575 VA
Silver cadmium
oxide
Max. current:
5 Amps
100 mA to
5 Amps
Max. voltage: 150†
VDC or 300 VAC
* Contact for Standard DC Voltage version only
(Table A).
** Contact code for Sensitive DC Voltage version only
(Table B) and sensitive DC current version.
† If switching voltage is greater than 30 VDC, special
precautions must be taken. Contact the factory.
EXAMPLE: AZ431–22–10LUS:
A. Basic number: AZ431–22– indicates six pole, plugin/ solder terminals, standard coil, 3 VDC, 11 ohms.
B. Contact code: 10LUS indicates bifurcated crossbar
fine silver/gold plated contacts, Form C, UL and CUR
approved.
08/21/08W
AZ420
TYPICAL CONTACT LIFE EXPECTANCY WHILE SWITCHING RESISTIVE LOADS
NUMBER OF OPERATIONS
CONTACT
CODE
CURRENT
—LUS
1 MA
10 MA
2A
2A
—HUS
5A
5A
STANDARD
COIL
ADJUSTMENT
VOLTAGE
.1
6
28
115
VDC
VDC
VDC
VAC
1
1
6
6
28 VDC
115 VDC
X
X
X
X
SENSITIVE
COIL
ADJUSTMENT
108
108
105
105
1
1
5
5
1 X 105
1 X 105
X
X
X
X
108
108
105
105
1 X 104
1 X 104
NOTE: Relays operate at nominal coil voltage or 1.33 x must operate value for sensitive versions.
UL APPROVED CONTACT RATINGS
CONTACT CODE
UL RATINGS
40LUS, 10LUS
2 Amps at 26 VDC and 115 VAC
4LUS, 1LUS
2 Amps at 28 VDC and 115 VAC
4HUS, 1HUS
5 Amps at 28 VDC and 115 VAC
25
5
20
4
15
3
10
2
5
1
0
0
1.5
2
2.5
3
RELEASE TIME (MILLISECONDS)
OPERATE TIME (MILLISECONDS)
TYPICAL OPERATE AND RELEASE TIME
(STANDARD DC VOLTAGE VERSION)
3.5
MUTIPLE OF MUST OPERATE VOLTAGE
NOTES:
1. Coils not diode suppressed
2. Switched battery voltage source
8/21/08W
AZ420
MECHANICAL DATA
PC BOARD TERMINALS
SOLDER/PLUG IN TERMINALS
.197
(5)
.735 Max
(18.7)
1.187 Max
(30)
.735 Max
(18.7)
.940 Max 2 Pole
(24)
.940 Max 2 Pole
(24)
1.172 Max 4 Pole
(30)
1.172 Max 4 Pole
(30)
1.395 Max 6 Pole
(36)
1.395 Max 6 Pole
(36)
.416
(10.6)
.043 ± .002
(1.1 ± 0.05)
.098
(2.5)
.354
(9)
.040
(1)
3-48 NC 2A
NIB .091 DIA x .030 High
(2.3)
(0.8)
2 Holes
.040 DIA
(1)
1.230 Max
(31)
.134
(3.4)
.177
(4.5)
SUGGESTED PANEL LAYOUT
PC BOARD LAYOUT
.343 2 Pole
(8.7)
.169 Ref
(4.3)
.406
(10.3)
Holes
.050 DIA + .004
(1.3)
- .000
.562 4 Pole
(14.3)
.781 6 Pole
(19.8)
.940 Max
2 Pole
(24)
.320
(8.1)
.212
(5.4)
.106 (2.7)
.531
.424 (13.5)
(10.8)
.281
(7.1)
.140 (3.5)
.281
(7.1)
1.172 Max
4 Pole
(30)
.543
(13.8)
1.395 Max
6 Pole
(36)
.142 Ref
(3.6)
2 Holes
.120 DIA
(3)
.354
(9)
.656
(16.7)
.458
(11.6)
.138 Ref
(3.5)
Viewed toward terminals
Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010"
8/21/08W
AZ420
WIRING DIAGRAM
FORM C CONTACT
22
12
13
20
21
11
16
9
10
19
9
10
14
15
8
17
18
8
10
6
7
13
6
7
16
6
7
8
9
5
11
12
5
14
15
5
4
3
2
1
4
TWO POLE
3
2
1
3
4
FOUR POLE
2
1
SIX POLE *
Viewed toward terminals
* Not available in sealed version
MECHANICAL DATA AZ2428; 2429 Versions
1. TWO POLE (DPDT)
.750
(19)
.115
(2.9)
.010
(0.3)
1.200
(30.5)
.980
(24.9)
2. FOUR POLE (4PDT)
.750
(19)
1.210
(30.7)
.115
(2.9)
.010
(0.3)
1.200
(30.5)
.010 ± .005
(0.25 ± .13)
TYP.
.042 ± .005
(1.0 ± .13)
TYP.
8/21/08W
AZ420
Sockets & Hardware for AZ420 Series
GENERAL DATA
Dielectric Strength
(at sea level)
1500 Vrms between all elements
Insulation
Resistance
1012 ohms minimum at 25°C, 100 VDC
• International standard spacing — accommodates
most cradle-type relays
• Unique knife-edge connector assures
positive contact
• Unbreakable fiberglass filled polyester
base material
• Spacing riser prevents flux contamination
• PC terminal spacing for 0.1 or 0.2 inch grids
• UL CUR file E171533
Current Rating
5 Amps maximum, continuous
Ambient Temperature
-55°C (-67°F) to 105°C (220°F)
ORDERING DATA
FEATURES
# OF POLES
2
SOCKET
ST140–A1
RETAINING CLIPS
ST140–1
4
ST141–A1
ST141–1
Maximum Temperature Machine soldering: 240°C (460°F)
Vibration
10 g at 5–55 Hz (socket soldered into PC
board with relay inserted and held in place
with retainer)
Shock
50 g any position (socket soldered into PC
board with relay inserted and held in place
with retainer)
Terminals
Combination type facilitates hand wiring or
PC board mounting
Contact Material
Tin bronze silver plated
MECHANICAL SPECIFICATIONS
PANEL LAYOUT
MECHANICAL DATA
.748
[19.0]
.354
[9.0]
PC BOARD LAYOUT
.350
[8.9]
.173
[4.4]
.010
[0.25]
.100
[2.54]
.173
[4.4]
.656
[16.7]
14
ø.126
[ø3.2]
1.184
[30.1]
.042
[1.06]
.280
[7.1]
1.217
(30.9)
.426
[10.8]
CLEARANCE HOLE
FOR RELAY MOUNTING
STUD OR GROUND CLIP
.562
[14.3]
.140
[3.56]
.120
(3.04)
.280
[7.1]
.413
[10.5]
.354
[9.0]
.426
[10.8]
CLEARANCE HOLE
FOR RELAY MOUNTING
STUD OR GROUND CLIP
.100
[2.54]
.173
[4.4]
.100
[2.54]
6
10
.343
[8.7]
.140
[3.56]
.120
(3.04)
.280
[7.1]
.280
[7.1]
.354
[9.0]
1.30
(33.02)
RETAINING
CLIP
2 POLE
2
.150
[3.81]
.656
[16.7]
1.00
(25.4)
1
3
VIEWED TOWARD TERMINALS
.042
[1.06]
.413
[10.5]
.500
[12.7]
.450
[11.4]
.010
[0.25]
ø.126
[ø3.2]
5
12
4
.120
(3.04)
.173
[4.4]
7
G
ø.052
[ø1.3]
1.30
(33.02)
.748
[19.0]
.354
[9.0]
11
RETAINING
CLIP
4 POLE
8
15
6
13
2x ø.120
[3.05]
.350
[8.9]
.978
[24.8]
HOLE FOR
GROUND
CLIP
.100
[2.54]
10
9
16
.120
(3.04)
2x ø.120
[3.05]
HOLE FOR
GROUND
CLIP
ø.052
[ø1.3]
8
.100
[2.54]
7
9
5
G
.500
[12.7]
2
4
3
1
.100
[2.54]
.150
[3.81]
.450
[11.4]
VIEWED TOWARD TERMINALS
Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010"
8/21/08W