0RODUCT $ATA 3HEET Contact Factory for Replacement Model 7!44 $ $#$# 0/7%2 3500,9 $.8 &%!452%3 &ULLY )SOLATED /UTPUTS ,OW 0ROFILE v X v X v /NE4WO4HREE AND &OUR /UTPUT -ODELS !CTIVE #URRENT 3HARING ON 6 /PTIONAL &AN #OVERS 4OP-OUNTED OR %ND-OUNTED !CTIVE )NRUSH #URRENT ,IMITING $%3#2)04)/. 6$# )NPUT 4HE $.8 IS A COMPACT WATTMULTIPLE OUTPUT POWER SUPPLY THAT OPERATES FROM A 6$# SOURCE !LL OUTPUTS ARE FULLY ISOLATED AND REGULATED!CTIVE CURRENT SHARING CIRCUITRY ON /UTPUT TOGETHER WITH CONTROL FUNCTIONS AND ALARM OPTIONS SIMPLIFIES . AND REDUNDANT APPLICATIONS &AN AND DISK DRIVE APPLICATIONS ARE HANDLED BY THE PEAK CURRENT RATINGS OF THE AUXILIARY OUTPUTS !'%.#9 !002/6!,3 3EE h3AFETYvSECTION ON PAGE FOR MORE INFORMATION 7EBSITE HTTPWWWCDPOWERELECTRONICSCOM 0OWER %LECTRONICS $IVISION 5NITED 3TATES % "RITANNIA $RIVE 4UCSON !RIZONA 4EL &AX #$4ECHNOLOGIES.#, -ILTON +EYNES-+ "5 5+ 4EL &AX !NY DATA PRICES DESCRIPTIONS OR SPECIFICATIONS PRESENTED HEREIN ARE SUBJECT TO REVISION BY #$ 4ECHNOLOGIES )NC WITHOUT NOTICE 7HILE SUCH INFORMATION IS BELIEVED TO BE ACCURATE AS INDICATED HEREIN #$ 4ECHNOLOGIES )NC MAKES NO WARRANTY AND HEREBY DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIEDWITH REGARD TO THE ACCURACY OR COMPLETENESS OF SUCH INFORMATION&URTHER BECAUSE THE PRODUCTS FEATURED HEREIN MAY BE USED UNDER CONDITIONS BEYOND ITS CONTROL #$ 4ECHNOLOGIES )NC HEREBY DISCLAIMS ALL WARRANTIES EITHER EXPRESS OR IMPLIED CONCERNING THE FITNESS OR SUITABILITY OF SUCH PRODUCTS FOR ANY PARTICULAR USE OR IN ANY SPECIFIC A PPLICATION OR ARISING FROM ANY COURSE OF DEALING OR USAGE OF TRADE4HE USER IS SOLELY RESPONSIBLE FOR DETERMINING THE SUITABILITY OF THE PRODUCTS FEATURED HEREIN FOR USERS INTENDED PURPOSE AND IN USERS SPECIFIC APPLICATION #$ 4ECHNOLOGIES )NC DOES NOTWARRANT OR RECOMMEND THAT ANY OF ITS PRODUCTS BE USED IN ANY LIFE SUPPORT OR AVIATION OR AEROSPACE APPLICATIONS $.8 2%6 " 0AGE Input Specifications Parameter Conditions Min Typ Max Units 36 48 72 VDC 36VDC 25 APK 72VDC 50 APK Operating Range DC Inrush Current Limiting Efficiency 48VDC at full load 70 % Remote Sense Remote Sense is provided on Output #1 and will compensate for 0.7V of line drop. Remote Sense leads are protected against open, short and reversal. Transient Response The peak output voltage excursion will not exceed 2% and will recover within 1% in 200 μsec for a 25% load step change. Remote On/Off (Optional) The power supply is turned on with a TTL logic ‘1’ (or open) signal and turned off by a switch closure or TTL logic ‘0’ referenced to (-) sense terminal. Over Temperature Protection Thermal switch turns off power supply if overheating occurs and automatically restarts. Over Voltage Protection Output #1: 6.5V ± 0.5 VDC. The power supply will latch off until AC power is cycled. Over Current Protection Individual current limit on all outputs. Automatic recovery upon fault removal. Safety Safety Certified to UL/CUL to 1950, File Number E131694. TUV to EN60950/IEC 950. Cooling The unit is designed to operate with 30 CFM of airflow. Active Inrush Current Limiting Inrush current is independent of ambient temperature. Page 2 DNX350 4/2002 REV B Output Voltages and Maximum Rated Loads MODEL NUMBER OUTPUT #1 VOUT IMAX OUTPUT #2 VNOM IMAX/IPK OUTPUT #3 VNOM IMAX/IPK OUTPUT #4 VNOM IMAX/IPK DNX350-U1A +5V 50A DNX350-U3A ± 5V 50A ± 12V 10A/12A ± 12V 8A/10A - - DNX350-U3B ± 5V 50A ± 15V 10A/12A ± 15V 8A/10A - - DNX350-U4C ± 5V 50A ± 12V 10A/12A ± 12V 8A/10A ± 5V 3.0A DNX350-U4D ± 5V 50A ± 12V 10A/12A ± 12V 8A/10A ± 24V 1.5A DNX350-U4E ± 5V 50A ± 12V 10A/12A ± 12V 8A/10A ± 12V 3.0A DNX350-U4F ± 5V 50A ± 15V 10A/12A ± 15V 8A/10A ± 5V 3.0A DNX350-U4G ± 5V 50A ± 15V 10A/12A ± 15V 8A/10A ± 24V 1.5A DNX350-U4H ± 5V 50A ± 15V 10A/12A ± 15V 8A/10A ± 12V 3.0A DNX350-U4I ± 5V 50A ± 15V 10A/12A ± 15V 8A/10A ± 12V 3.0A Output Specifications Parameter Limits Regulation Line ± 0.03% Load ±0.25% Cross ±0.05% Minimum Load Output #1 3.0A Auxiliary Outputs 0.1A Parameter Conditions Voltage Adustment Range Nominal line on all outputs PARD Min Typ Max ±5 Peak-to-peak 20 MHz bandwidth Units % 1 % P-P 0 50 °C -20 +70 °C Temperature Operating Storage Temperature Coefficient (TC) DNX350 4/2002 REV B After half hour warm-up ± 0.02 %/°C Page 3 Mechanical 6.94 TOP MOUNTED FAN FAN OPTION 3.34 1 NO. 1 +V OUTPUTS NO. 1 -V TB1 1 PLUS 2 AIR FLOW OUTPUT OUTPUT 4 3 ADJ. ADJ. MINUS 3 OUTPUT 5 ADJ. 4.85 3.60 3.90 1 1 0.62 0.55 TB2 6-32 MOUNTING LOCATED ON BOTTOM (4x) 8.50 0.25 1.99 9.00 END MOUNTED FAN 3.00 8.50 0.250 2.15 0.550 J10 TB2 3 2 1 3.900 4.850 J9 AIR FLOW 1.00 OUTPUT NO. 1 RETURN 10-32 STUD 9.00 6-32 THD 4 PLC'S NOTES: All measurements are in inches COOLING: The DNX350 is designed to operate with 30 CM airflow. SHOCK AND VIBRATION: The DNX350 meets the requirements of MIL STD-810D. WEIGHT: Approximately 3 lbs. Terminal Block 1 POS FUNCTION Terminal Block 2 POS J9 Connector J10 Connector* Molex No. 22-28-1090 1 DC + 1 -V2 2 DC - 2 +V2 1 + Sense 1 DC+ 3 -V3 2 - Sense 2 DC- 4 +V3 3 N/C 3 GROUND -V4 4 N/C +V4 5 Start Up Sync. 6 N/C 7 Remote Inhibit 8 Current Share 9 Control Signal Rtn Ground 5 6 FUNCTION AMP 1-480701-1 PIN 3 Page 4 FUNCTION OUTPUT NO. 1 10-32 STUD 1 POS FUNCTION *Used with end-mounted fan cover, option “V” DNX350 4/2002 REV B