Click Here to download this file: http://www.murata-ps.com/data/acdcsupplies/tps_dnx350.pdf

Contact Factory for Replacement Model
7!44
$
$#$#
0/7%2 3500,9
$.8
&%!452%3
&ULLY )SOLATED /UTPUTS
,OW 0ROFILE v X v X v
/NE4WO4HREE AND &OUR
/UTPUT -ODELS
!CTIVE #URRENT 3HARING ON 6
/PTIONAL &AN #OVERS
4OP-OUNTED OR %ND-OUNTED
!CTIVE )NRUSH #URRENT ,IMITING
$%3#2)04)/.
4HE $.8 IS A COMPACT WATTMULTIPLE OUTPUT POWER SUPPLY
THAT OPERATES FROM A 6$# SOURCE !LL OUTPUTS ARE FULLY
ISOLATED AND REGULATED!CTIVE CURRENT SHARING CIRCUITRY ON /UTPUT
TOGETHER WITH CONTROL FUNCTIONS AND ALARM OPTIONS SIMPLIFIES
. AND REDUNDANT APPLICATIONS &AN AND DISK DRIVE APPLICATIONS
ARE HANDLED BY THE PEAK CURRENT RATINGS OF THE AUXILIARY OUTPUTS
6$# )NPUT
!'%.#9 !002/6!,3
3EE h3AFETYvSECTION ON PAGE FOR MORE INFORMATION
www.murata-ps.com
Technical enquiries - email: [email protected], tel: +1 508 339 3000
Input Specifications
Parameter
Conditions
Min
Typ
Max
Units
36
48
72
VDC
36VDC
25
APK
72VDC
50
APK
Operating Range
DC
Inrush Current Limiting
Efficiency
48VDC at full load
70
%
Remote Sense
Remote Sense is provided on Output #1 and will
compensate for 0.7V of line drop. Remote Sense leads
are protected against open, short and reversal.
Transient Response
The peak output voltage excursion will not exceed 2% and
will recover within 1% in 200 μsec for a 25% load step
change.
Remote On/Off (Optional)
The power supply is turned on with a TTL logic ‘1’ (or open)
signal and turned off by a switch closure or TTL logic ‘0’
referenced to (-) sense terminal.
Over Temperature Protection
Thermal switch turns off power supply if overheating occurs
and automatically restarts.
Over Voltage Protection
Output #1: 6.5V ± 0.5 VDC.
The power supply will latch off until AC power is cycled.
Over Current Protection
Individual current limit on all outputs. Automatic recovery
upon fault removal.
Safety
Safety Certified to UL/CUL to 1950, File Number E131694.
TUV to EN60950/IEC 950.
Cooling
The unit is designed to operate with 30 CFM of airflow.
Active Inrush Current Limiting
Inrush current is independent of ambient temperature.
www.murata-ps.com
Technical enquiries - email: [email protected], tel: +1 508 339 3000
Output Voltages and Maximum Rated Loads
MODEL NUMBER
OUTPUT #1
VOUT
IMAX
OUTPUT #2
VNOM IMAX/IPK
OUTPUT #3
VNOM IMAX/IPK
OUTPUT #4
VNOM IMAX/IPK
DNX350-U1A
+5V
50A
DNX350-U3A
± 5V
50A
± 12V
10A/12A
± 12V
8A/10A
-
-
DNX350-U3B
± 5V
50A
± 15V
10A/12A
± 15V
8A/10A
-
-
DNX350-U4C
± 5V
50A
± 12V
10A/12A
± 12V
8A/10A
± 5V
3.0A
DNX350-U4D
± 5V
50A
± 12V
10A/12A
± 12V
8A/10A
± 24V
1.5A
DNX350-U4E
± 5V
50A
± 12V
10A/12A
± 12V
8A/10A
± 12V
3.0A
DNX350-U4F
± 5V
50A
± 15V
10A/12A
± 15V
8A/10A
± 5V
3.0A
DNX350-U4G
± 5V
50A
± 15V
10A/12A
± 15V
8A/10A
± 24V
1.5A
DNX350-U4H
± 5V
50A
± 15V
10A/12A
± 15V
8A/10A
± 12V
3.0A
DNX350-U4I
± 5V
50A
± 15V
10A/12A
± 15V
8A/10A
± 12V
3.0A
Output Specifications
Parameter
Limits
Regulation
Line
± 0.03%
Load
±0.25%
Cross
±0.05%
Minimum Load
Output #1
3.0A
Auxiliary Outputs
0.1A
Parameter
Conditions
Voltage Adustment Range
Nominal line on all outputs
PARD
Min
Typ
Max
±5
Peak-to-peak 20 MHz bandwidth
Units
%
1
% P-P
0
50
°C
-20
+70
°C
Temperature
Operating
Storage
Temperature Coefficient (TC)
www.murata-ps.com
After half hour warm-up
± 0.02
%/°C
Technical enquiries - email: [email protected], tel: +1 508 339 3000
Mechanical
6.94
TOP MOUNTED
FAN
FAN OPTION
3.34
1
NO. 1 +V
OUTPUTS
NO. 1 -V
TB1
1
PLUS
2
AIR FLOW
OUTPUT OUTPUT
4
3
ADJ.
ADJ.
MINUS
3
OUTPUT
5
ADJ.
4.85 3.60
3.90
1
1
0.62
0.55
TB2
6-32 MOUNTING LOCATED ON BOTTOM (4x)
8.50
0.25
1.99
9.00
END MOUNTED
FAN
3.00
8.50
0.250
2.15
0.550
J10
TB2
3
2
1
3.900
4.850
J9
AIR FLOW
1.00
OUTPUT NO. 1
RETURN
10-32 STUD
9.00
6-32 THD
4 PLC'S
NOTES: All measurements are in inches
COOLING: The DNX350 is designed to operate with 30 CM airflow.
SHOCK AND VIBRATION: The DNX350 meets the requirements of MIL STD-810D.
WEIGHT: Approximately 3 lbs.
Terminal Block 1
POS
FUNCTION
Terminal Block 2
POS
FUNCTION
OUTPUT NO. 1
10-32 STUD
1
J9 Connector
J10 Connector*
Molex No. 22-28-1090
PIN
AMP 1-480701-1
FUNCTION
POS
FUNCTION
1
DC +
1
-V2
2
DC -
2
+V2
1
+ Sense
1
DC+
3
-V3
2
- Sense
2
DC-
4
+V3
3
N/C
3
GROUND
5
-V4
4
N/C
6
+V4
5
Start Up Sync.
6
N/C
3
Ground
www.murata-ps.com
7
Remote Inhibit
8
Current Share
9
Control Signal Rtn
*Used with end-mounted fan cover,
option “V”
Technical enquiries - email: [email protected], tel: +1 508 339 3000