0RODUCT$ATA3HEET !-0 -/$5,!237)4#(%$-/$%2%#4)&)%2 2- &%!452%3 s 37)4#(%$-/$% s 0&# s %&&)#)%.#9 s (/437!0#!0!",% s !54/-!4)#,/!$3(!2).' s #/-0!#43):% s 3(%,&-/5.4%$ s "%,,#/2%"!3%$$%3)'. s 2%-/4%2%34!24&5.#4)/. s &2/.40!.%,#522%.4-%4%2 s "!44%29/2"!44%29,%33/0%2!4)/. s ).4%,,)'%.4()'(6/,4!'%3(54$/7. s '5!2!.4%%$./3).',%0!24&!),52%7),, 2%35,4)./54054()'(6/,4!'% $%3#2)04)/. s 4($ 4HE2--ODULAR3WITCHED-ODE2ECTIFIERISONEOF #$4ECHNOLOGIESFAMILYOFRECTIFIERSTHATMAYBEUSEDIN MODULAR POWER PLANTS 4HIS UNIT WILL FUNCTION IN PARALLEL WITH ANY RECTIFIER WITH SIMILAR R CURRENT CURRENT SHARING SHARING CAPACITIES 4HISCOMPACTVERSATILEANDEFFICIENTUNITISIDEALFORUSEIN DE EFFICIENT UNIT IS IDEAL FOR USE E IN SMALLTOMEDIUMCELLULARAND0#3SITES AN ND 0#3 SITES !'%.#9!002/6!,3 Contact Factory for Replacement Model )NTERNETHTTPWWWCDPOWERELECTRONICSCOM 0OWER%LECTRONICS$IVISION5NITED3TATES %"RITANNIA$RIVE4UCSON!RIZONA 0HONE&AX 2- 2%6 ! 0OWER%LECTRONICS$IVISION%UROPE #$4ECHNOLOGIES0OWER%LECTRONICS,TD 3HANNON)NDUSTRIAL%STATE 3HANNON#O#LARE)RELAND 4EL &AX 0AGE Input Specifications Parameter Conditions Operating Range Current (when supplying 30ADC at 48VDC) Min 45 - 65 Hz, single phase, no taps required 105 VAC 208 VAC 240 VAC Efficiency Power Factor Correction (PFC) input range between 105VAC-264VAC Typ Max Units 264 20 VAC AAC 10 8.5 AAC AAC 106 >85 >.99 % MEASUREMENTS OF RM4830 Module Shelf* Weight Height Depth Width Weight Height Depth Width 14 lbs. 5 U (8.75”) 15.55” 3.35” 21 lbs. 5 U (8.75”) 15.55” 23” rack mount * These measurements are specifically for the 180A Power Shelf for up to 6 quantity RM 4830. Please contact factory for other shelf and power plant options. GENERAL FEATURES Hot Swappable Modules These shelf-mounted modules are easy and safe to install or remove while system is operational without affecting the overall system’s performance. Current Limit When rectifier current reaches 30ADC - 32ADC, the unit will automatically limit the current down to short circuit conditions with no fold back. Parallel Operation and Automatic Load Sharing A series of RM4830 rectifiers will automatically share equal amounts of the load current when operating in parallel within ±5% of the average current for the load applied. LED Indicators The front panel includes a 10 segment yellow LED output current bar graph, a green normal operation LED, and a red rectifier failed LED. N+1 Operation The rectifier can operate in true N + 1 redundacy mode. Safety UL/CUL Recognized: UL 1950/CSA 950. File No.: E131694 EMI filtering to FCC and VDE-0875 limits. Remote Equalize The rectifier output may be changed from float to equalize via remote signal. Page 2 RM4830 6/98 REV A Output Specifications Parameter Conditions Min Typ Max Units Voltage Adjustment Range Regulation Load Current Filtering Voice band Wide band noise float voltage 40 60 VDC equalize voltage 0-100% load within specified input voltage and frequency range within a 10 - 100% rating 40 60 VDC 20 MHz bandwidth ENVIRONMENTAL Temperature Operating Storage Temperature Coefficient Humidity Altitude Heat Dissipation Audible Noise after half hour warm-up non-condensing @54V 2 ft. from any vertical surface ±0.5 ± 10 % % <32 <250 <40 dBrnC mV p-p mVrms 0 +32 -50 -58 0.01 0 0 0 +50 122 85 185 95 7000 2133 980 <65 °C °F °C °F V/°C % ft. m Btu/hr dBa PROTECTION, ALARM AND CONTROL SYSTEMS Rectifier Failure Alarm (RFA) Problems occurring because of an unacceptable relationship between the output power and load conditions will cause a Rectifier Failure Alarm (RFA). This alarm consists of a red LED. Conditions which may lead to an RFA are: Low Current - Output current has decreased to below 2% of its rated value. Unit Shutdown - Any shutdown occurrence due to overvoltage, external shutdown command, unacceptable ambient temperature conditions or low AC input voltage. Fan Malfunction - The fan has stopped operating or is not providing the airflow needed to cool the unit. Over Temperature - The ambient temperature has exceeded 50°C. RM4830 6/98 REV A High Voltage Shutdown (HVSD) The unit’s built-in high voltage limit is permanently set at 60.5VDC. When internal shutdown occurs, the unit may be restarted by a local switch or by a remote signal. Surge Protection The unit will withstand lightning and input surges of 6000V/3000A. Under Voltage Protection When input voltage is below 106 VAC (with tolerance), the rectifier’s operation is automatically inhibited. Output Circuit Protection Device (Fuse) The unit has one internal output protection fuse which is in series with the -48VDC output. Page 3 Mechanical SIDE 14.30 1.25 FRONT 4.95 + .25 FAN 3.35 4.70 + .25 4830 2.35 + .25 4.35 + .25 8.63 1st TEST BURN-IN HI-POT 2nd TEST QA 30 27 24 21 18 15 12 9 6 3 VOLTAGE PWR/RESET FLT EQL Standard Options are shown, consult factory for other available options. The information provided herein is believed to be reliable; however, C&D TECHNOLOGIES assumes no responsibility for inaccuracies or omissions. C&D TECHNOLOGIES assumes no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. C&D TECHNOLOGIES does not authorize or warrant any C&D TECHNOLOGIES product for use in life support devices/systems or in aircraft control applications. Page 4 RM4830 6/98 REV A