S/X-Band 100 W Traveling Wave Tube Amplifier Compact Four rack units tall (7.0 in, 133 mm) Versatile Ultra-wideband, automatic fault recycle, user-friendly microprocessor-controlled logic with integrated computer interface, VSWR soft-fail protection, digital metering, quiet operation for laboratory environment. An integral solid state pre-amplifier and IEEE interface are included as standard features. Efficient Utilizes dual-depressed collector helix traveling wave tube for maximum 1.5 kVA operation. Global Applications Model VZS/X-2776L1 Compact Medium Power Amplifier for EMI/EMC Test and Measurement Applications OPTIONS •Input Isolator (-1 dB gain) •Remote Control Panel •115 VAC External Step-Up Transformer 230 VAC operation. Meets International Safety Standard EN61010 and Electromagnetic Compatibility 2004/108/EC. Worldwide Support Backed by over 35 years of satellite communications experience, and CPI’s worldwide 24-hour customer support network that includes more than 20 regional factory service centers. 45 River Drive Georgetown, Ontario, Canada L7G 2J4 tel: +1 (905) 702-2228 fax: +1 (905) 877-5327 e-mail:[email protected] website:www.cpii.com/emc S/X-Band Specifications 100 W TWT Band Amplifier Specification Model VZS/X-2776L1 Frequency 4.0 to 10.0 GHz Output Power (min.), TWT Output Power (min.), Flange Gain 100 W min 70 W min. 44 dB min. at rated power output; 40 dB typ. at small signal RF Level Adjust Range 0 to 20 dB continuous Gain Stability ±0.25 dB/24 hr max. (at constant drive and temp.) Gain Variation 12.0 dB pk-pk max., typ. Input VSWR 2.5:1 typ. 1.5:1 max. (with optional input isolator) Output VSWR 2.5:1 typ. Load VSWR 1.5:1 max. for full spec compliance; 2.0:1 max. continuous operation; any value without damage Residual AM -50 dBc below 10 kHz; -20 [1.3 + log F (kHz)] dBc, 10 kHz to 500 kHz; -80 dBc above 500 kHz Phase Noise Meets IESS-308/309 with 3 dB margin Noise Figure Harmonic Content Primary Power 15 dB max. -3 dBc typical at lower band edge, decreasing to -15 dBc typ. at upper band edge 220-240 VAC ±10%, single phase, 47-63 Hz Power Consumption 1.4 kVA typ. 1.5 kVA max. Inrush Current 200% max. Ambient Temperature -10° to +40°C operating Relative Humidity Altitude Shock and Vibration 95% non-condensing Up to 10,000 ft (3000 m) with standard adiabatic derating of 2°/1000 ft. Designed to meet conditions normally encountered in the laboratory Acoustic Noise 65 dBA @ 3 ft. from amplifier Cooling (TWT) Forced air with integral blower. Rear air intake and exhaust. RF Input Connection Type N female RF Output Connection Type N female RF Output Monitor Type-N female, -57 dB nom. Dimensions (W x H x D) 19 x 7 x 24 in. (483 x 178 x 610 mm) Weight 70 lbs (32 kg) Safety EN61010 Quality Management System - ISO 9001:2008 For more detailed information, please refer to the corresponding CPI technical description if one has been published, or contact CPI. Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 234, ISSUE 3 dated AUG 2015