K-Band 50 W CW Hub-Mount TWTA RF Output Power From 18.0 to 26.5 GHz Provides 40 W CW at the flange. Easy to Use and Versatile Extensive diagnostic capability. Automatic output power control. Time stamped event log. Automatic filament shutdown. Manual override control. Dual communications interfaces. Continuous RF attenuator adjustment in 0.1 dB steps. Ruggedly Built Meets MIL-STD-810E. Global Applications Meets International Safety Standard EN61010 and Electromagnetic Compatibility 2004/108/EC. Worldwide Support Backed by over 35 years of satellite communications experience, and CPI’s worldwide 24-hour customer support network that includes more than 20 regional factory service centers. Model TE01KO-C 50 watt K-band TWTA for EMC/EMI Test Applications OPTIONS •RF Input Attenuator •Gain Variation Equalizer •Integral Linearizer •Mounting Configurations •Low Gain (remove SSIPA) •Others Available Upon Request •Ethernet Interface 45 River Drive Georgetown, Ontario, Canada L7G 2J4 tel: +1 (905) 702-2228 fax: +1 (905) 877-5327 e-mail:[email protected] website:www.cpii.com/emc K-Band Specifications 50 W K-Band Hub Mount TWTA Specification Model TE01KO-C Frequency 18.0 to 26.5 GHz Output Power (min.), TWT Output Power (min.), Flange 50 W CW 40 W CW Bandwidth 8.5 GHz Gain 46 dB typ. at rated power output RF Level Adjust Range 0 to 20 dB Gain Stability ±0.25 dB/24 hr max. (after 30 minute warmup and at constant drive and temperature) Gain Variation +/-6.0 dB max (+/-3.0 dB max. with gain variation equalizer option) VSWR Input Output Load 2.0:1 max 2.5:1 typ. 2.0:1 max. without damage Harmonic Content -6 dB max. Noise and Spurious -50 dBc typ. excluding harmonics Prime Power 100 to 264 VAC single phase, 2 wire, 47 to 63 Hz Power Consumption 600 VA nom. Inrush Current Operating Temperature 200% -40°C to +50°C (derate by 1.9°C per 1,000 ft. above sea level) Non-Operating Temperature -50°C to +70°C Relative Humidity 100% condensing Operating Altitude 10,000 ft above sea level (3,048 m) Non-Operating Altitude 50,000 ft above sea level (15,240 m) Vibration MIL-STD-810E, Method 514.4, Procedure 1, Category 1 Shock 10 g, 11 ms half sine Acoustic Noise <68 dBA max. at 1 meter Air Flow 150 cfm Cooling Forced air, 2.0” clearance required Input RF Connector Type K Female Output RF Connector Dimensions WR-42G 9.6” H x 11.8” W x 20.6” L (244 x 300 x 522 mm) Weight 49 lbs (22.2 kg) nom. Quality Management System - ISO 9001:2008 For more detailed information, please refer to the corresponding CPI technical description if one has been published, or contact CPI. Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 389, ISSUE 4 dated OCT 2014