TE01AI-C

Ka-Band
50 W CW Rack-Mount TWTA
RF Output Power From 26.5 to 40.0 GHz
Provides 40 W CW at the flange.
Easy to Use and Versatile
Extensive diagnostic capability. Automatic output power
control. Time stamped event log. Automatic filament
shutdown. Manual override control. Dual communications
interfaces. Continuous RF attenuator adjustment in
0.1 dB steps.
Ruggedly Built
Meets MIL-STD-810E.
Global Applications
Meets International Safety Standard EN61010 and
Electromagnetic Compatibility 2004/108/EC.
Worldwide Support
Model TE01AI-C
50 watt S/C-band TWTA
for EMC/EMI Test Applications
OPTIONS
•RF Input Attenuator
•Gain Variation Equalizer
•Integral Linearizer
•Mounting Configurations
•Low Gain (remove SSIPA)
•Others Available Upon Request
•Ethernet Interface
Backed by over 35 years of satellite communications
experience, and CPI’s worldwide 24-hour customer
support network that includes more than 20 regional
factory service centers.
45 River Drive
Georgetown, Ontario, Canada L7G 2J4
tel:
+1 (905) 702-2228
fax:
+1 (905) 877-5327
e-mail:[email protected]
website:www.cpii.com/emc
Ka-Band
Specifications 50 W K-Band Rack Mount TWTA
Specification
Model TE01AI-C
Frequency
26.5 to 40.0 GHz
Output Power (min.), TWT
Output Power (min.), Flange
50 W CW
40 W CW
Bandwidth
13.5 GHz
Gain
46 dB typ. at rated power output
RF Level Adjust Range
0 to 20 dB
Gain Stability
±0.25 dB/24 hr max. (after 30 minute warmup and at constant drive and temperature)
Gain Variation
±6 dBc max. (±3 dBc max. with optional gain variation equalizer)
VSWR
Input
Output
Load
2.0:1 max.
2.5:1 typ.
2.0:1 max. without damage
Noise and Spurious
Prime Power
-50 dBc typ. excluding harmonics
100 to 264 VAC single phase, 2 wire, 47 to 63 Hz
Power Consumption
800 VA nom.
Inrush Current
Operating Temperature
200%
-10°C to +50°C (derate by 1.9°C per 1,000 ft. above sea level)
Non-Operating Temperature
-40°C to +70°C
Relative Humidity
95% non-condensing
Operating Altitude
10,000 ft above sea level (3,048 m)
Non-Operating Altitude
50,000 ft above sea level (15,240 m)
Vibration
MIL-STD-810E, Method 514.4, Procedure 1, Category 1
Shock
10 g, 11 ms half sine
Acoustic Noise
<68 dBA max. at 1 meter
Air Flow
100 cfm
Cooling
Forced air, 2.0” clearance required
Input RF Connector
2.92 mm Type K Female
Output RF Connector
Dimensions
WR-28
5.2” H x 19.0” W x 24.0” L (133 x 483 x 610 mm)
Weight
65 lbs (29.5 kg) nom.
Quality Management
System - ISO 9001:2008
For more detailed information, please refer to the corresponding CPI technical description if one has been
published, or contact CPI. Specifications may change without notice as a result of additional data or product
refinement. Please contact CPI before using this information for system design.
MKT 388, ISSUE 3 dated OCT 2014