Ka-Band 50 W CW Rack-Mount TWTA RF Output Power From 26.5 to 40.0 GHz Provides 40 W CW at the flange. Easy to Use and Versatile Extensive diagnostic capability. Automatic output power control. Time stamped event log. Automatic filament shutdown. Manual override control. Dual communications interfaces. Continuous RF attenuator adjustment in 0.1 dB steps. Ruggedly Built Meets MIL-STD-810E. Global Applications Meets International Safety Standard EN61010 and Electromagnetic Compatibility 2004/108/EC. Worldwide Support Model TE01AI-C 50 watt S/C-band TWTA for EMC/EMI Test Applications OPTIONS •RF Input Attenuator •Gain Variation Equalizer •Integral Linearizer •Mounting Configurations •Low Gain (remove SSIPA) •Others Available Upon Request •Ethernet Interface Backed by over 35 years of satellite communications experience, and CPI’s worldwide 24-hour customer support network that includes more than 20 regional factory service centers. 45 River Drive Georgetown, Ontario, Canada L7G 2J4 tel: +1 (905) 702-2228 fax: +1 (905) 877-5327 e-mail:[email protected] website:www.cpii.com/emc Ka-Band Specifications 50 W K-Band Rack Mount TWTA Specification Model TE01AI-C Frequency 26.5 to 40.0 GHz Output Power (min.), TWT Output Power (min.), Flange 50 W CW 40 W CW Bandwidth 13.5 GHz Gain 46 dB typ. at rated power output RF Level Adjust Range 0 to 20 dB Gain Stability ±0.25 dB/24 hr max. (after 30 minute warmup and at constant drive and temperature) Gain Variation ±6 dBc max. (±3 dBc max. with optional gain variation equalizer) VSWR Input Output Load 2.0:1 max. 2.5:1 typ. 2.0:1 max. without damage Noise and Spurious Prime Power -50 dBc typ. excluding harmonics 100 to 264 VAC single phase, 2 wire, 47 to 63 Hz Power Consumption 800 VA nom. Inrush Current Operating Temperature 200% -10°C to +50°C (derate by 1.9°C per 1,000 ft. above sea level) Non-Operating Temperature -40°C to +70°C Relative Humidity 95% non-condensing Operating Altitude 10,000 ft above sea level (3,048 m) Non-Operating Altitude 50,000 ft above sea level (15,240 m) Vibration MIL-STD-810E, Method 514.4, Procedure 1, Category 1 Shock 10 g, 11 ms half sine Acoustic Noise <68 dBA max. at 1 meter Air Flow 100 cfm Cooling Forced air, 2.0” clearance required Input RF Connector 2.92 mm Type K Female Output RF Connector Dimensions WR-28 5.2” H x 19.0” W x 24.0” L (133 x 483 x 610 mm) Weight 65 lbs (29.5 kg) nom. Quality Management System - ISO 9001:2008 For more detailed information, please refer to the corresponding CPI technical description if one has been published, or contact CPI. Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 388, ISSUE 3 dated OCT 2014