S/C-Band 535 W CW Rack-Mount TWTA RF Output Power in S and C-Bands Select from one version which provides 500 W CW from 2.5 to 7.5 GHz, or another which provides 125 W CW from 2.0 to 2.5 GHz and 370 W CW from 2.5 to 8.0 GHz. Easy to Use and Versatile Extensive diagnostic capability. Automatic output power control. Time stamped event log. Automatic filament shutdown. Manual override control. Dual communications interfaces. Continuous RF attenuator adjustment in 0.1 dB steps. Ruggedly Built Meets MIL-STD-810E. Global Applications Meets International Safety Standard EN61010 and Electromagnetic Compatibility 2004/108/EC. Model TE05SCI-C 535 watt S/C-band TWTA for EMC/EMI Test Applications OPTIONS •RF Input Attenuator •Gain Variation Equalizer •Integral Linearizer •Mounting Configurations •Low Gain (remove SSIPA) •Others Available Upon Request •Ethernet Interface Worldwide Support Backed by over 35 years of satellite communications experience, and CPI’s worldwide 24-hour customer support network that includes more than 20 regional factory service centers. 45 River Drive Georgetown, Ontario, Canada L7G 2J4 tel: +1 (905) 702-2228 fax: +1 (905) 877-5327 e-mail:[email protected] website:www.cpii.com/emc S/C-Band Specifications 535 W S/C-Band Rack Mount TWTA Specification Model TE05SCI-C Frequency 2.5 to 7.5 GHz option 2.0 to 8.0 GHz option Output Power (min.), TWT Output Power (min.), Flange 535 W 500 W 150 W from 2.0 to 2.5 GHz; 450 W from 2.5 to 8.0 GHz 125 W from 2.0 to 2.5 GHz; 370 W from 2.5 to 8.0 GHz Bandwidth 5 GHz 6 GHz Gain 53.5 dB typ. at rated power output; 55.5 dB typ. at small signal RF Level Adjust Range 0 to 20 dB Gain Stability ±0.25 dB/24 hr max. (after 30 minute warmup and at constant drive and temperature) Gain Variation 26 dB pk-pk (10 dB pk-pk with gain variation equalizer option) VSWR Input Output Load Residual AM 2.0:1 max. 2.5:1 typ. 2.0:1 max. -50 dBc below 10 kHz; -20[1.3 + log F (kHz)] dBc, 10 kHz to 500 kHz; -85 dBc above 500 kHz Noise and Spurious -50 dBc typ. excluding harmonics Harmonic Content Prime Power -3 dBc max. 180 to 264 VAC single phase, 2 wire, 47 to 63 Hz Power Consumption 3000 VA nom. Inrush Current Operating Temperature 200% -10°C to +50°C (derate by 1.9°C per 1,000 ft. above sea level) Non-Operating Temperature -40°C to +70°C Relative Humidity 95% non-condensing Operating Altitude 10,000 ft above sea level (3,048 m) Non-Operating Altitude Vibration 50,000 ft above sea level (15,240 m) MIL-STD-810E, Method 514.4, Procedure 1, Category 1 Shock 10 g, 11 ms half sine Acoustic Noise <68 dBA max. at 1 meter Air Flow 100 cfm Cooling Forced air, 2.0” clearance required Input RF Connector Output RF Connector Dimensions Type N Female Type SC Female Standard, Type N Female Optional 8.7” H x 19.0” W x 24.0” L (221 x 483 x 610 mm) Weight 90 lbs (40.9 kg) nom. Quality Management System - ISO 9001:2008 For more detailed information, please refer to the corresponding CPI technical description if one has been published, or contact CPI. Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 385, ISSUE 3 dated OCT 2014