CRYDOM PB8

PB8
MOUNTING BOARD
• Plug-compatible logic connections
• Screw terminal barrier block for load connections
• Resident pull-up resistors
• 5 amp field-replaceable fuses
•
All even-numbered logic connections are
logic ground
Input and output modules accepted interchangeably
Operate with 5, 15 or 24 volt logic supplies
Captive-screw retaining system for standard-size
modules
•
•
•
(LITTLEFUSE #251005 or equivalent)
• LEDs indicate logic status
MECHANICAL SPECIFICATIONS
SCREW TERMINAL
LOGIC SUPPLY
BARRIER STRIP
6-32 SCREW TERMINAL
POWER BARRIER STRIP
(see note 2)
8.0 (203,2)
DIMENSIONS: INCHES (MILLIMETERS)
TOLERANCE:+-0.020 ( +- 0,50)
7.5 (190,5)
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16
-
+
REPLACEABLE 5 AMP
LINE FUSE (8)
(see note 4)
GORDOS DIGITAL I/O
MODULES SOLD SEPERATELY
0.3 (7,6)
0
1
2
3
4
5
6
3.5 (88,9)
SWAGED STANDOFF
THRU HOLE
0.15 (3,2) DIA.
(4)
3.0 (76,2)
2.6 (66,0)
1.4 (35,6)
7
PULL UP RESISTORS
3.3K OHM (8)
0.45 (11,4)
0.75 (19,1)
SIGNAL INPUT/OUTPUT
50 TRACE (0.1" CENTERS)
MALE CARD EDGE
(see note 1)
2.2 (55,9)
LED STATUS INDICATORS (8)
NOTES: 1) MATING CONNECTOR IS BERG 66317-150 OR EQUIVALENT.
SPECIFY SUFFIX "V" FOR OPTIONAL CA26HM-2F-SR CIRCUIT ASSEMBLY OR
EQUIVALENT 26 CONDUCTOR PERPENDICULAR-TO-THE-BOARD
MALE PIN CONNECTOR.
2) 6-32 SCREW TERMINAL BARRIER STRIPS ACCEPT WIRE SIZES FROM 24 TO 12 AWG.
3) OPTIONAL JUMPERS ARE AVAILABLE TO INTERCONNECT BARRIER
STRIP COMMONS. ORDER 1 EACH "JS8".
4) LITTLE FUSE 251005 OR EQUIVALENT.
LOGIC SUPPLY
BARRIER STRIP 1 2
+
BOTTOM
ALL
EVEN
PINS
“V” OR “C” OPTION
EDGE CONN TOP
+ LOGIC 49 25
SIGNAL INPUT/OUTPUT
50 TRACE (0.1" CENTERS)
MALE CARD EDGE OR
OPTIONAL PIN CONNECTOR
+LOGIC
APPROVALS
UL
E79183
CSA 38595
47
45
43
41
39
37
35
33
25
1
3 4
5 6
POWER BARRIER STRIP
7 8
9 10 1112 1314
5 AMP LINE FUSE
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
23
21
19
17
15
13
11
9
1
CUSTOMER INSTALLED
OPTIONAL JUMPERS
FOR CONNECTING LOGIC
SUPPLY THRU CARD EDGE
CONNECTOR
15 16
I/O MODULE
PIN SOCKETS
AMP #645979-1
OR EQUIVALENT
LED STATUS
INDICATOR
(8)
PULL UP RESISTOR
3.3K OHM
(8)
Rev. 070808
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / PERIGO
HAZARD OF
ELECTRIC
SHOCK,
EXPLOSION,
OR ARC FLASH.
x Disconnect all
power before
installing or
working with
this equipment.
x Verify all
connections
and replace all
covers before
turning on
power.
Failure to follow
these
instructions will
result in death
or serious injury.
RIESGO DE
DESCARGA
ELECTRICA O
EXPLOSION.
x Desconectar
todos los
suministros de
energia a este
equipo antes
de trabajar
con este equipo.
x Verificar todas
las conexiones
y colocar todas
las tapas antes
de energizer
el equipo.
El
incumplimiento
de estas
instrucciones
puede provocar
la muerte o
lesiones serias.
RISQUE DE
DESCHARGE
ELECTRIQUE
OU EXPLOSION
x Eteindre
toutes les
sources
d'énergie de
cet appareil
avant de
travailler
dessus de cet
appareil
x Vérifier tous
connections, et
remettre tous
couverts en
olace avant de
mettre sous
De non-suivi de
ces instructions
provoquera la
mort ou des
lésions sérieuses
sérieuses.
GEFAHR EINES
ELEKTRISCHE
N SCHLAGES
ODER EINER
EXPLOSION.
x Stellen Sie
jeglichen
Strom ab, der
dieses Gerät
versorgt, bevor
Sie an dem
Gerät Arbeiten
durchführen
x Vor dem
Drehen auf
Energie alle
Anschlüsse
überprüfen
und alle
Abdeckungen
ersetzen.
Unterlassung
dieser
Anweisungen
können zum
Tode oder zu
schweren
Verletzungen
führen.
RISCHIO DI
SCOSSA
ELETTRICA O
DELL’ESPLOSI
ONE.
x Spenga tutta
l'alimentazion
e che fornisce
questa
apparecchiatu
ra prima del
lavorare a questa
apparecchiatu ra
x Verificare tutti
i collegamenti
e sostituire
tutte le coperture
prima della
rotazione
sull'alimentazi one
L'omissione di
seguire queste
istruz ioni
provocherà la
morte o di
lesioni serie
RISCO DE
DESCARGA
ELÉTTRICA OU
EXPLOSÃO
x Desconectar
o equipamento
de toda á
energia antes
de instalar ou
trabalhar com
este equipamen
to
x Verificar todas
as conexões e
recolocar todas
as tampas
antes de religar
o equipamento
O não cumprimento
destas instruções
pode levar á morte
ou lesões sérias.
ANNEX - ENVIROMENTAL INFORMATION