PB-32M - Crydom

PB-32M
MOUNTING BOARD
• Plug-compatible logic connections
• Screw terminal barrier block for load connections
• Resident pull-up resistors
• 5 amp field-replaceable fuses
• All even-numbered logic connections are
logic ground
• Input and output modules accepted interchangeably
• Operate with 5, 15 or 24 volt logic supplies
• Optional Hold Down Bar for retaining “M” series modules
(LITTLEFUSE #251005 or equivalent)
• LEDs indicate logic status
MECHANICAL SPECIFICATIONS
POWER TERMINAL STRIP (4)
(see notes 2,3,4)
LOGIC SUPPLY
TERMINAL STRIP
(see note 2)
DIMENSIONS: INCHES (MILLIMETERS)
TOLERANCE:+-0.020 ( +- 0,50)
0.4 (10,2)
10.2 (259,1)
5.475 (139,1)
4.225 (107,3)
1
16
17
32
1.25 (31,8)
REPLACEABLE 1 AMP
LOGIC SUPPLY FUSE
(see note 5)
REPLACEABLE 5 AMP
LINE FUSES (32)
(see note 6)
49
2.6 (66,0)
SIGNAL INPUT/OUTPUT
50 TRACE (0.1" CENTERS)
MALE CARD EDGE
(see note 1)
6.2 (157,5)
OPTIONAL HOLD DOWN
BAR KIT (see note 7)
6-32 NYLON
STANDOFF (2)
SWAGED STANDOFF
THRU HOLE 0.15 (3,8) DIA.
(8)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
3.2 (81,3)
LED STATUS
INDICATOR (32)
1
1.8 (45,7)
GORDOS DIGITAL I/O
MODULES SOLD SEPERATELY
1.25 (31,8)
64
49
48
PULL UP RESISTOR
3.3K OHM (32)
33
0.25 (6,4)
0.75 (19,1)
1.9 (47,6)
NOTES: 1) MATING CONNECTOR IS BERG 66317-150 OR EQUIVALENT.
SPECIFY SUFFIX 'C' FOR OPTIONAL 65823-093 OR EQUIVALENT
MALE PIN CONNECTOR FOR PARALLEL-TO-THE-BOARD CABLE
CONNECTION. SPECIFY SUFFIX 'V' FOR OPTIONAL CIRCUIT ASSEMBLY CA-50H-2B-SR
OR EQUIVALENT MALE PIN CONNECTOR FOR PERPENDICULAR-TO-THE-BOARD
CABLE CONNECTION.
2) 4-40 SCREW TERMINAL STRIPS ACCEPT WIRE SIZES FROM 26 TO 14 AWG.
3) OPTIONAL JUMPERS ARE AVAILABLE TO INTERCONNECT BARRIER STRIP
ORDER 2 EACH "JM2" AND 4 EACH "JM8".
LOGIC SUPPLY
BARRIER STRIP
+
1 AMP LOGIC
SUPPLY FUSE
SIGNAL INPUT/OUTPUT
50 TRACE (0.1" CENTERS)
MALE CARD EDGE
OR OPTIONAL MALE PIN
CONNECTOR
4) PHOENIX MKD51.5 5.08mm SERIES (OR EQUIVALENT) SCREW TERMINAL
BLOCKS STANDARD. SPECIFY SUFFIX "A" FOR BOARD-MOUNTED PHOENIX
MSTBVA 1.5/16-G-5.08 (OR EQUIVALENT) MALE CONNECTOR. SPECIFY
SUFFIX "B" FOR BOARD-MOUNTED PHOENIX MSTBVA 1.5/16-G-5.08
(OR EQUIVALENT) MALE CONNECTOR AND MATING PHOENIX MSTBVA 1.5/16-ST-5.08
(OR EQUIVALENT) FEMALE. SCREW-TERMINAL PLUG-IN CONNECTOR.
5) LITTLE FUSE 251001 OR EQUIVALENT.
6) LITTLE FUSE 251005 OR EQUIVALENT.
7) TWO HOLD-DOWN BAR KITS ARE AVAILABLE SEPARATELY. MODEL NO. 11.06.418
EMPLOYS A PLAIN ALUMINUM CHANNEL WHILE MODEL NO. 11.06.305 PROVIDES
POCKETS IN THE CHANNEL FOR INDIVIDUAL MODULES.
POWER BARRIER STRIP
1 2
3 4
5 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
5 AMP LINE
FUSES (32)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
1
3
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
2
45
46
43
49
48
44
50
47
41
36
42
35
40
38
39
37
PULL UP
RESISTOR
3.3K OHM
(32)
LED STATUS
INDICATOR
(32)
14
12
13
11
16
9
15
10
4
1
7
3
2
8
5
6
LOGIC
GROUND
17
19
21
22
23
25
26
28
30
31
32
34
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
POWER BARRIER STRIP
Rev. 020410
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / PERIGO
HAZARD OF
ELECTRIC
SHOCK,
EXPLOSION,
OR ARC FLASH.
x Disconnect all
power before
installing or
working with
this equipment.
x Verify all
connections
and replace all
covers before
turning on
power.
Failure to follow
these
instructions will
result in death
or serious injury.
RIESGO DE
DESCARGA
ELECTRICA O
EXPLOSION.
x Desconectar
todos los
suministros de
energia a este
equipo antes
de trabajar
con este equipo.
x Verificar todas
las conexiones
y colocar todas
las tapas antes
de energizer
el equipo.
El
incumplimiento
de estas
instrucciones
puede provocar
la muerte o
lesiones serias.
RISQUE DE
DESCHARGE
ELECTRIQUE
OU EXPLOSION
x Eteindre
toutes les
sources
d'énergie de
cet appareil
avant de
travailler
dessus de cet
appareil
x Vérifier tous
connections, et
remettre tous
couverts en
olace avant de
mettre sous
De non-suivi de
ces instructions
provoquera la
mort ou des
lésions sérieuses
sérieuses.
GEFAHR EINES
ELEKTRISCHE
N SCHLAGES
ODER EINER
EXPLOSION.
x Stellen Sie
jeglichen
Strom ab, der
dieses Gerät
versorgt, bevor
Sie an dem
Gerät Arbeiten
durchführen
x Vor dem
Drehen auf
Energie alle
Anschlüsse
überprüfen
und alle
Abdeckungen
ersetzen.
Unterlassung
dieser
Anweisungen
können zum
Tode oder zu
schweren
Verletzungen
führen.
RISCHIO DI
SCOSSA
ELETTRICA O
DELL’ESPLOSI
ONE.
x Spenga tutta
l'alimentazion
e che fornisce
questa
apparecchiatu
ra prima del
lavorare a questa
apparecchiatu ra
x Verificare tutti
i collegamenti
e sostituire
tutte le coperture
prima della
rotazione
sull'alimentazi one
L'omissione di
seguire queste
istruz ioni
provocherà la
morte o di
lesioni serie
RISCO DE
DESCARGA
ELÉTTRICA OU
EXPLOSÃO
x Desconectar
o equipamento
de toda á
energia antes
de instalar ou
trabalhar com
este equipamen
to
x Verificar todas
as conexões e
recolocar todas
as tampas
antes de religar
o equipamento
O não cumprimento
destas instruções
pode levar á morte
ou lesões sérias.
ANNEX - ENVIROMENTAL INFORMATION