CUI VOF-80-12

rev.
page
page
1 of 4
date
date
02/2010
DESCRIPTION: switching power supply
PART NUMBER: VOF-80
features
•
•
•
•
•
•
•
no-load power consumption < 0.5W
universal input 85~264 V ac
over current, over voltage protected
industry standard footprint
efficiency up to 89%
safety approved to CB, TUV, CE, UL/cUL
conducted EMI meets EN55022 class B and FCC class B
MODEL
VOF-80-3.3
VOF-80-5
VOF-80-12
VOF-80-15
VOF-80-24
VOF-80-48
notes:
output voltage
(V dc)
3.3
5
12
15
24
48
output current 4 total regulation 1,2 ripple & noise 3
(A)
(%)
(mVp-pmax.)
10
±5
120
10
±5
120
6.66
±5
120
5.33
±5
150
3.33
±5
240
1.66
±5
480
efficiency
(%)
75
76
85
86
87
89
1. Measured from high line to low line at rated load.
2. Measured from full load to 10% load at 115 V ac.
3. Ripple & noise are measured at 20MHz bandwidth with 0.1 µf ceramic & 10 µf electrolytic capacitors on the output.
The two earth ground pads are connected to input earth ground.
4. See derating curves
INPUT
parameter
input frequency
input voltage
input current
inrush current
input fuse
conditions/description
output power derated from 85-90 V ac
AC input of 110 V ac
AC input of 220 V ac
AC input of 110 V ac, full load, cold start
AC input of 220 V ac, full load, cold start
built-in, non-user serviceable
min
47
85
nom
max
63
264
25
50
units
Hz
V ac
mA
mA
A
A
max
units
+5
+0.05
mS
%
%/°C
1500
800
OUTPUT
parameter
efficiency
hold up time
adjustability
temp. coefficient
conditions/description
see table above, typical values measured
at 115 V ac, full load
at 115 V ac, full load
min
8
-10
-0.05
nom
PROTECTION CIRCUIT
parameter
output overload
output over voltage
output short circuit
conditions/description
current limiting starts at 105% of the rated output current and recovers automatically
output voltage is limited by TVS clamping to: 6.8 V for 3.3 & 5 V models, 135% for all other models
protected, long-term short circuit may reduce reliability
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383
www.v-infinity.com
rev.
PART NUMBER: VOF-80
page
2 of 4
date
02/2010
DESCRIPTION: switching power supply
GENERAL AND SAFETY
parameter
conditions/description
switching frequency
operating temp.
storage temp.
operating humidity non-condensing
storage humidity
non-condensing
operating altitude
storage altitude
leakage current
per EN60950, at 264 V ac
isolation voltage
primary to secondary
(for 1 minute)
primary to transformer core
min
nom
65
max
0
-20
20
20
10000 / 3000
30000 / 9000
60
85
90
95
1.5
3000
1500
primary to ground
1500
RoHS
compliant
safety
approved to CB, TUV EN60950, CE, UL/cUL 60950-1
EMI
conducted emission comply with FCC class B, EN55022 class B
insulation resistance
measured at 500 V dc, room temperature
50
units
kHz
ºC
ºC
% RH
% RH
ft / m
ft / m
mA
V ac
V ac
V ac
MΩ
DERATING CURVES
input vs. load (for all models)
,QSXWYROWDJH$&9
temperature vs. load (for 12, 15, 24, 48 V models)
temperature vs. load (for 3.3, 5 V models)
$PELHQWWHPSHUDWXUHć
IRUFHGDLUZLWKYHORFLW\RI06
IUHHDLUFRQYHFWLRQ
$PELHQWWHPSHUDWXUHć
IRUFHGDLUZLWKYHORFLW\RI06
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383
www.v-infinity.com
rev.
page
3 of 4
date
02/2010
DESCRIPTION: switching power supply
PART NUMBER: VOF-80
MECHANICAL
parameter
dimensions
weight
cooling method
conditions/description
4” (102 mm) x 2” (51 mm) x 1.28” (32.6 mm)
0.2 Kg
free air convection or forced air (see derating curves below)
MATING CONNECTORS
parameter
ac input (CN1)
dc output (CN2)
conditions/description
mates with Molex housing 09-50-7031 with Molex 2878 series crimp contact
mates with Molex housing 09-50-7061 with Molex 2878 series crimp contact
MOUNTING METHOD
Horizontal
(performace evaluations conducted under this mounting method)
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383
www.v-infinity.com
REV.
A
B
DESCRIPTION
NEW DRAWING
updated pin designation
DATE
9/15/2009
4/1/2010
102.0 4.016
94.0 3.701
CN2
6
5
4
3
2
1
CN1
3
2
43.0 1.693 1
51.0 2.008
3.5 0.138
(4 PLCS)
MOUNTING HOLE
NOTES:
CRITICAL DIMENSIONS
FOR INSPECTION
32.6 1.283
RoHS
TOLERANCE: ±1.0mm
1.6 0.063
3.0 MAX
(LEAD)
20050 SW 112th Ave.
Tualatin, OR 97062
Phone: 503-612-2300
800-275-4899
Fax: 503-612-2383
Website: www.cui.com
CN1
1
L
2
no pin
3
N
TITLE:
VOF-80 MECHANICAL DRAWING
PART NO.
CN2
PC FILE NAME:
VOF-80-mech
COPYRIGHT 2010 BY CUI INC.
1
+V
2
+V
3
+V
4
-V
5
-V
6
-V
ZRJ
B
UNITS:
VOF-80-mech
DRAWN BY:
REV:
MM [INCHES]
APPROVED BY:
SCALE:
1:1