CUI VOF-25-3.3

1/3
VOF-25 Switching Power Supply
Rev. 07-2007
Features
•
•
•
•
•
•
•
•
RoHS Compliant
Universal input 85~264 Vac
Output over-current protected
Output over-voltage protected
Industry standard foot-print
Efficiency up to 82%
Safety approved to TUV, CE; UL/cUL
Conducted EMI meets EN55022
class B and FCC class B
Model
VOF-25-3.3
VOF-25-5
VOF-25-7.5
VOF-25-9
VOF-25-12
VOF-25-15
Voltage
(V)
3.3
5
7.5
9
12
15
Current
(A)
4.4
4.4
3.0
2.7
2.0
1.6
Total 1,2
Regulation
±5%
±5%
±5%
±5%
±5%
±5%
Ripple & Noise 3
(mVp-p max)
50
50
75
90
120
150
Efficiency
(%)
70
73
73
77
80
80
VOF-25-24
24
1.0
±5%
240
82
Notes:
1. Measured from High Line to Low Line at Full load.
2. Measured from Full load to 10% load at 110 VAC.
3. Ripple & Noise measured at 20 MHz BW, with a 0.1 µF ceramic cap and a 10 µF electrolytic cap on the output and two earth
ground pads are connected to input earth ground.
Derating Curves
1. Output Power vs. Ambient temperature
(%)
b. All other models
(%)
(%)
a. 3.3 V and 5 V models
(18 CFM)
2. Output Power vs. Input Voltage
(%)
All Models
Input Voltage (VAC)
V-INFINITY LLC, 9615 SW Allen Blvd., Suite 103, Beaverton, OR 97005
1-866-372-1258
www.v-infinity.com
2/3
VOF-25 Switching Power Supply
Rev. 07-2007
Input
Parameter
Input Frequency
Conditions/Description
Input Voltage
Input Current
Output power derated from 85-90 VAC
AC Input of 110 VAC
Inrush Current
AC Input of 210 VAC
Measured at 110 VAC at full load, cold start
Input fuse
Measured at 220 VAC at full load, cold start
Built-in, non-user serviceable.
Min
47
Nom
85
Max
63
Units
Hz
264
VAC
mA
700
350
20
mA
A
40
A
Max
Units
+5
+0.05
mS
%
%/ºC
Max
50
85
90%
95%
3,000
10,000
Units
ºC
ºC
RH
RH
m
ft
9,000
30,000
m
ft
1.5
mA
Output
Parameter
Efficiency
Hold up time
Adjustability
Temp. Coefficient
Conditions/Description
Min
Nom
See table above. Typical values measured at 115 VAC, full load.
At 115 VAC, full load
16
Adjustable with built-in trim pot.
- 5
-0.05
Protection Circuit
Parameter
Overload
Conditions/Description
Current limiting starts at 105% of the rated output current and
Output Over-voltage
Short Circuit
recovers automatically.
Output voltage is limited to 115% by TVS clamping.
Protected. Long term short circuit may reduce reliability.
General and Safety
Parameter
Operating temp.
Storage temp.
Operating humid.
Storage humid.
Operating altitude
Conditions/Description
See derating curves.
Non-condensing
Non-condensing
Min
0
-20
20%
20%
Nom
Storage altitude
EMI
Safety
Conducted emissions comply with FCC class B, EN55022 class B
Approved to TUV EN60950, CE, CB; UL/cUL 60950-1
RoHS
Leakage Current
Isolation Voltage
(HI-POT)
2002/95/EC
Per EN60950, 264 VAC
Applied for 1 minute.
Primary to secondary:
Insulation Resistance
MTBF ( @ 25ºC)
Warranty
Primary to transformer core:
Primary to earth ground:
Measured at 500 VDC, at room temp.
MIL-HDBK-217F
Standard Warranty Length
V-INFINITY LLC, 9615 SW Allen Blvd., Suite 103, Beaverton, OR 97005
3000
VAC
1500
1500
50
VAC
VAC
MΩ
250K
2
1-866-372-1258
hours
years
www.v-infinity.com
3/3
VOF-25 Switching Power Supply
Rev. 07-2007
Mechanical
Parameter
Conditions/Description
Dimensions
Weight
3.5”(88.9mm) x 2”(51mm) x 0.8”(20.32mm)
Min
Cooling method
free air convection (see derating curve on p. 1)
Nom
Max
Units
0.09
kg
Mating Connectors
Parameter
Conditions/Description
AC Input (CN1)
DC Output (CN2)
Mates with Molex housing 09-50-3031 with Molex 2878 series crimp contact.
Mates with Molex housing 09-50-3041 with Molex 2878 series crimp contact.
Outline Drawing
90.0 3.54
81.9±0.1 3.22
51.0 2.01
42.8±0.1 1.68
3
2
1
4
3
CN2
2
1
CN2
CN1(0411-3P)
1
2
3
N
no pin
L
CN2(0411-4P)
VADJ
3.5 (4 PLCS)
MOUNTING HOLE
1
2
3
4
-V
-V
+V
+V
*Tolerance: ±1
*Dimensions in mm
20.32 0.80
3.0 MAX
(LEAD)
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers
to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications.
Nothing will be covered outside of standard product warranty.
V-INFINITY LLC, 9615 SW Allen Blvd., Suite 103, Beaverton, OR 97005
1-866-372-1258
www.v-infinity.com