page 1 of 5 date 11/19/2007 DESCRIPTION: switching power supply PART NUMBER: VPF-S200-XXRI series features ·power factor correction ·power good signal ·short circuit protection ·over load, voltage, temperature protection ·approved to UL/cUL, TUV, CE with CB scheme ·N+1 parallel redundancy ·extended temperature range: -40 ~ +75°C available MODEL output 1, 2, 3 (V) VPF-S200-03RI VPF-S200-05RI VPF-S200-12RI VPF-S200-24RI VPF-S200-36RI VPF-S200-48RI notes: 3 5 12 24 32 48 - 4 V 6 V 18 V 30 V 46 V 56 V preset voltage (V) 3.3 V 5 V 12 V 24V 36 V 48 V max. output 4 power / current (A) with force air convection 30 A 200W 200W 200W 200W 200W 22 A 22 A 150W 150W 150W 150W regulation 5 ripple & noise 5, 6 (Vp-p) ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% 1. customer must specify output voltage on PO 2. output is fully isolated 3. output voltage is measured at output power connector 4. maximum 200 W with 18. cfm forced ventilation 5. 1% minimum load is required to maintain the ripple and regulation 6. ripple and noise are measured from 10 KHz to 20 MHz at output terminals with a 0.1 µF ceramic capacitor and a 22 µF capacitor in parallel. 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382 PART NUMBER: VPF-S200-XXRI series page 2 of 5 date 11/19/2007 DESCRIPTION: switching power supply INPUT parameter input frequency conditions/description min 47 nom input voltage input current 90~132 / 180~264 auto-selectable AC input of 115 VAC inrush current AC input of 230 VAC peak measured at 115 VAC at full load, cold start power factor peak measured at 230 VACat full load, cold start 70 A active power factor correction meets EN61000-3-2 class A (total output power not to exceed 200 W) 90 max 63 units Hz 264 5 VAC A 2.5 35 A A OUTPUT parameter transient response conditions/description output voltage returns to within 1% in less than 2.5ms for a min 50% load change. peak transient does not exceed 5%. turn-on and turn-off overshoot will not exceed 5% over nominal voltage measured at 230 V and full load: 3.3 V model overshoot efficiency start up time hold up time adjustability LED display power good 5 V model 12 V model all other models at 120 V ac, full load at 120 V ac, full load output use adjustable when green (LED1) is on, power supply is operating normally designated as PG on the CN1. this signal goes high 100-500 mS after the output reaches regulation. low at least 1 mS before loss of regulation. - 5 nom max units 70 % 75 80 83 1 20 +5 % % % S mS % PROTECTION CIRCUITS parameter input fuse overload output over-voltage short circuit over temp. conditions/description one T5A / 250V fuse inserted in primary current limiting starts at 110~135% of the rated output current in foldback mode and recovers automatically output is protected against overvoltage. Unit shuts down and latches when voltage at output terminals exceeds 130%. ac input needs to be reset to restart the power supply. trip without damage and auto-recovery. Power supply shuts down when temperature is in excess of 85 ºC. auto recovery. 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382 PART NUMBER: VPF-S200-XXRI series page 3 of 5 date 11/19/2007 DESCRIPTION: switching power supply GENERAL & SAFETY parameter operating temp. optional operating temp. storage temp. optional storage temp. operating humid. storage humid. operating altitude conditions/description derates linearly from 100% load at 50°C to 50% load at 70°C derates linearly from 100% load at 50°C to 37.5% load at 75°C non-condensing non-condensing min 0 nom max 40 units °C -40 75 °C -20 -40 5% 5% 85 85 90% 95% 3,000 10,000 9,000 30,000 ºC ºC RH RH m ft m ft storage altitude EMI safety conducted emissions comply with FCC part 15, CISPR 22 class B approved to UL 1950(E222889), CSA C22.2 No. 60950-1-03, TUV EN60950-1, CE Mark (LVD), EN61000-3-2, & IEC61000-4 series regulations, CB leakage current at 240 V ac 1.5 mA vibration acceleration ±7.35 M/(SxS), on X, Y, and Z axis 5 50 Hz isolation voltage applied for 3 seconds. (HI-POT) primary to secondary: 3000 VAC primary to transformer core: 1500 VAC primary to earth ground: 1500 VAC grounding test allowable resistance measured when 25 A current is 0.1 Ω applied from the ground pin of the three pronged plug to the farthest earthed connection point. RoHS yes warranty standard warranty length 2 years MTBF according to MIL-HDBK-217 at 30°C 100,000 hours burn-in full load, at 45 ±5°C, 230 V ac 1 hours cooling built-in dc fan speed control Note: Customer must specify extended temperature on PO. MECHANICAL parameter dimensions weight mountin screws conditions/description 6.8”(172.7mm) x 3.8”(96.5mm) x 1.5”(38.1mm) U-case min nom max units 600 g one set of 8 threaded mounting holes available on the enclosure A:M4, maximum insertion depth of 0.2 inches. MATING CONNECTORS parameter AC input(option 1) conditions/description Molex Part No. 26-48-1201 or similar (5 pin). Suggested mating plug: Molex Part No. 09-91-0500 or equivalent (5 pin, 3 used) AC input(option 2) Terminal block Part No. FTB-702-3P (3 pin, M3 Screw) 7.62mm spacing Suggested mating connector: Molex 19198-0016 or similar Note: Input connector must be specified on PO. 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382 PART NUMBER: VPF-S200-XXRI series page 4 of 5 date 11/19/2007 DESCRIPTION: switching power supply OUTPUT CONNECTOR - (CN2) parameter output (option 1) output (option 2) conditions/description min nom Molex Part No. 09-91-1200 or similar. (12 pin) Output pin assignment, VO+ (Pins 1-6), VO- (Pins 7-12) Suggested mating connector: Molex 12 pin (part No. 09-91-1200) Howder Terminal block Part No. HD-301-4P (4 pin, M3.5 Screw) 11mm spacing Output pin assignment, VO+ (Pins 1-2), VO- (Pins 3-4) Suggested mating connector: Molex 19198-0045 or similar. max units conditions/description min nom max JS B6B-XH-A Suggested mating connector: JS-2001-06 or equivalent , Contact: SXH-002T-P0.6. 1. FAN+ 2. FAN3. RTN 4. PG 5. REMO 6. RTN units Note: Output connector must be specified on PO. LOGIC CONNECTOR - (CN3) parameter Logic Pin Assignments: 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382 page 5 of 5 date 11/19/2007 DESCRIPTION: switching power supply PART NUMBER: VPF-S200-XXRI series VO+ VO+ VO- INPUT VO- OUTPUT OUTLINE DRAWING 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382