CUI VPF-S200-48RI

page
1 of 5
date
11/19/2007
DESCRIPTION: switching power supply
PART NUMBER: VPF-S200-XXRI series
features
·power factor correction
·power good signal
·short circuit protection
·over load, voltage, temperature protection
·approved to UL/cUL, TUV, CE with CB
scheme
·N+1 parallel redundancy
·extended temperature range: -40 ~ +75°C
available
MODEL
output 1, 2, 3
(V)
VPF-S200-03RI
VPF-S200-05RI
VPF-S200-12RI
VPF-S200-24RI
VPF-S200-36RI
VPF-S200-48RI
notes:
3
5
12
24
32
48
-
4 V
6 V
18 V
30 V
46 V
56 V
preset
voltage
(V)
3.3 V
5 V
12 V
24V
36 V
48 V
max. output 4
power / current (A)
with force air
convection
30 A
200W
200W
200W
200W
200W
22 A
22 A
150W
150W
150W
150W
regulation 5
ripple & noise 5, 6
(Vp-p)
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
1. customer must specify output voltage on PO
2. output is fully isolated
3. output voltage is measured at output power connector
4. maximum 200 W with 18. cfm forced ventilation
5. 1% minimum load is required to maintain the ripple and regulation
6. ripple and noise are measured from 10 KHz to 20 MHz at output terminals with a 0.1 µF ceramic capacitor and a 22 µF capacitor in parallel.
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
PART NUMBER: VPF-S200-XXRI series
page
2 of 5
date
11/19/2007
DESCRIPTION: switching power supply
INPUT
parameter
input frequency
conditions/description
min
47
nom
input voltage
input current
90~132 / 180~264 auto-selectable
AC input of 115 VAC
inrush current
AC input of 230 VAC
peak measured at 115 VAC at full load, cold start
power factor
peak measured at 230 VACat full load, cold start
70
A
active power factor correction meets EN61000-3-2 class A (total output power not to exceed 200 W)
90
max
63
units
Hz
264
5
VAC
A
2.5
35
A
A
OUTPUT
parameter
transient response
conditions/description
output voltage returns to within 1% in less than 2.5ms for a
min
50% load change. peak transient does not exceed 5%.
turn-on and turn-off overshoot will not exceed
5% over nominal voltage
measured at 230 V and full load:
3.3 V model
overshoot
efficiency
start up time
hold up time
adjustability
LED display
power good
5 V model
12 V model
all other models
at 120 V ac, full load
at 120 V ac, full load
output use adjustable
when green (LED1) is on, power supply is operating normally
designated as PG on the CN1. this signal goes high
100-500 mS after the output reaches regulation.
low at least 1 mS before loss of regulation.
- 5
nom
max
units
70
%
75
80
83
1
20
+5
%
%
%
S
mS
%
PROTECTION CIRCUITS
parameter
input fuse
overload
output over-voltage
short circuit
over temp.
conditions/description
one T5A / 250V fuse inserted in primary
current limiting starts at 110~135% of the rated output current in foldback mode and recovers automatically
output is protected against overvoltage. Unit shuts down and latches when voltage at output terminals
exceeds 130%. ac input needs to be reset to restart the power supply.
trip without damage and auto-recovery.
Power supply shuts down when temperature is in excess of 85 ºC. auto recovery.
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
PART NUMBER: VPF-S200-XXRI series
page
3 of 5
date
11/19/2007
DESCRIPTION: switching power supply
GENERAL & SAFETY
parameter
operating temp.
optional operating
temp.
storage temp.
optional storage temp.
operating humid.
storage humid.
operating altitude
conditions/description
derates linearly from 100% load at 50°C to
50% load at 70°C
derates linearly from 100% load at 50°C to
37.5% load at 75°C
non-condensing
non-condensing
min
0
nom
max
40
units
°C
-40
75
°C
-20
-40
5%
5%
85
85
90%
95%
3,000
10,000
9,000
30,000
ºC
ºC
RH
RH
m
ft
m
ft
storage altitude
EMI
safety
conducted emissions comply with FCC part 15, CISPR 22 class B
approved to UL 1950(E222889), CSA C22.2 No. 60950-1-03, TUV EN60950-1, CE Mark (LVD),
EN61000-3-2, & IEC61000-4 series regulations, CB
leakage current
at 240 V ac
1.5
mA
vibration
acceleration ±7.35 M/(SxS), on X, Y, and Z axis
5
50
Hz
isolation voltage
applied for 3 seconds.
(HI-POT)
primary to secondary:
3000
VAC
primary to transformer core:
1500
VAC
primary to earth ground:
1500
VAC
grounding test
allowable resistance measured when 25 A current is
0.1
Ω
applied from the ground pin of the three pronged plug
to the farthest earthed connection point.
RoHS
yes
warranty
standard warranty length
2
years
MTBF
according to MIL-HDBK-217 at 30°C
100,000
hours
burn-in
full load, at 45 ±5°C, 230 V ac
1
hours
cooling
built-in dc fan speed control
Note: Customer must specify extended temperature on PO.
MECHANICAL
parameter
dimensions
weight
mountin screws
conditions/description
6.8”(172.7mm) x 3.8”(96.5mm) x 1.5”(38.1mm) U-case
min
nom
max
units
600
g
one set of 8 threaded mounting holes available on the enclosure
A:M4, maximum insertion depth of 0.2 inches.
MATING CONNECTORS
parameter
AC input(option 1)
conditions/description
Molex Part No. 26-48-1201 or similar (5 pin).
Suggested mating plug: Molex Part No. 09-91-0500 or equivalent (5 pin, 3 used)
AC input(option 2)
Terminal block Part No. FTB-702-3P (3 pin, M3 Screw) 7.62mm spacing
Suggested mating connector: Molex 19198-0016 or similar
Note: Input connector must be specified on PO.
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
PART NUMBER: VPF-S200-XXRI series
page
4 of 5
date
11/19/2007
DESCRIPTION: switching power supply
OUTPUT CONNECTOR - (CN2)
parameter
output (option 1)
output (option 2)
conditions/description
min
nom
Molex Part No. 09-91-1200 or similar. (12 pin)
Output pin assignment, VO+ (Pins 1-6), VO- (Pins 7-12)
Suggested mating connector: Molex 12 pin (part No. 09-91-1200)
Howder Terminal block Part No. HD-301-4P (4 pin, M3.5 Screw) 11mm spacing
Output pin assignment, VO+ (Pins 1-2), VO- (Pins 3-4)
Suggested mating connector: Molex 19198-0045 or similar.
max
units
conditions/description
min
nom
max
JS B6B-XH-A
Suggested mating connector: JS-2001-06 or equivalent , Contact: SXH-002T-P0.6.
1. FAN+
2. FAN3. RTN
4. PG
5. REMO
6. RTN
units
Note: Output connector must be specified on PO.
LOGIC CONNECTOR - (CN3)
parameter
Logic
Pin Assignments:
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
page
5 of 5
date
11/19/2007
DESCRIPTION: switching power supply
PART NUMBER: VPF-S200-XXRI series
VO+
VO+
VO-
INPUT
VO-
OUTPUT
OUTLINE DRAWING
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382