1/3 VOF-65 Series Switching Power Supply Rev. 07-2007 Features • • • • • • • • RoHS compliant Universal input 85~264 Vac Output over-current protected Output over-voltage protected Industry standard foot-print Efficiency up to 88% Safety approved to TUV, CE; UL/cUL Conducted EMI meets EN55022 class B and FCC class B Model VOF-65-3.3 VOF-65-5 VOF-65-7.5 VOF-65-9 VOF-65-12 VOF-65-15 VOF-65-24 VOF-65-48 Voltage Current (V) 3.3 5 7.5 9 12 15 24 48 (A) 8.0 8.0 6.6 6.6 5.4 4.3 2.7 1.35 Total 1, 2 Ripple & Noise 3 Efficiency (mVp-p max) 50 50 75 90 120 150 240 480 (%) 74 78 78 82 84 85 86 88 Regulation ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% Notes: 1. Measured from High Line to Low Line at Full load. 2. Measured from Full load to 10% load at 110 VAC. 3. Ripple & Noise measured at 20 MHz BW, with a 0.1 µF ceramic cap and a 10 µF electrolytic cap on the output and the two earth ground pads are connected to input earth ground. Derating Curves 1. Output Power vs. Ambient temperature b. All other models 100 Load factor ( %) Load factor ( %) a. 3.3, 5, 7.5 V models 2 80 1 1 .Convection 3 2 .Forced air(0.5m /min) 60 40 (18 CFM) 20 100 2 80 1 1 .Convection 3 2 .Forced air(0.5m /min) 60 40 (18 CFM) 20 0 0 A mounting A mounting 0 10 20 B mounting 10 30 40 20 30 50 60 40 50 0 10 20 30 40 50 60 10 20 30 40 50 B mounting Ambient temperature( c) Ambient temperature( c) 2. Output Power vs. Input Voltage Load factor ( %) All Models 100 80 60 40 20 0 0 85 90 110 220 264 Input Voltage AC(V) V-INFINITY LLC, 20050 SW 112th Ave., Tualatin, OR 97062 1-866-372-1258 www.v-infinity.com 2/3 VOF-65 Series Switching Power Supply Rev. 07-2007 Input Parameter Conditions/Description Input Frequency Input Voltage Input Current Output power derated from 85-90 VAC AC Input of 110 VAC Inrush Current AC Input of 220 VAC Measured at 110 VAC at full load, cold start Input fuse Measured at 220 VAC at full load, cold start Built-in, non-user serviceable. Min Nom Max Units 47 63 Hz 85 264 VAC mA 1400 700 25 mA A 50 A Max Units +5 +0.05 mS % %/ºC Output Parameter Efficiency Hold up time Adjustability Temp. Coefficient Conditions/Description Min Nom See table above. Typical values measured at 115 VAC, full load. At 115 VAC, full load 8 Adjustable with built-in trim pot. - 5 -0.05 Protection Circuit Parameter Overload Output Over-voltage Short Circuit Conditions/Description Current limiting starts at 105% of the rated output current and recovers automatically. Output voltage is limited to 115% by TVS clamping. Protected. Long term short circuit may reduce reliability. General and Safety Parameter Switching frequency Operating temp. Storage temp. Operating humid. Storage humid. Conditions/Description Min See derating curves. 0 -20 20% 20% Non-condensing Non-condensing Operating altitude Storage altitude EMI Safety RoHS Leakage Current Isolation Voltage (HI-POT) Conducted emissions comply with FCC class B, EN55022 class B Approved to TUV EN60950, CE, CB; UL/cUL 60950-1 2002/95/EC Per EN60950, 264 VAC Applied for 1 minute. Primary to secondary: 3000 Primary to transformer core: 1500 Primary to earth ground: 1500 Insulation Resistance Measured at 500 VDC, at room temp. 50 MTBF ( @ 25ºC) MIL-HDBK-217F 250K Warranty Standard Warranty Length V-INFINITY LLC, 20050 SW 112th Ave., Tualatin, OR 97062 1-866-372-1258 Nom 60 Max 50 85 90% 95% Units KHz ºC ºC RH RH 3,000 10,000 9,000 30,000 m ft m ft 1.5 mA 2 VAC VAC VAC MΩ hours years www.v-infinity.com 3/3 VOF-65 Series Switching Power Supply Rev. 07-2007 Mechanical Parameter Dimensions Conditions/Description 4”(102mm) x 2”(51mm) x 1.26”(32mm) Min Weight Cooling method free air convection (see derating curve on p. 1) Nom Max Units 0.17 kg Mating Connectors Parameter AC Input (CN1) Conditions/Description Mates with Molex housing 09-50-3031 with Molex 2878 series crimp contact. DC Output (CN2) Mates with Molex housing 09-50-3041 with Molex 2878 series crimp contact. Outline Drawing 102.0 4.02 94.0±0.1 3.70 LED CN1 51.0 2.01 3 2 1 4 3 CN2 2 1 43.2±0.1 1.70 CN1(0411-3P) 1 2 3 L no pin N CN2(0411-4P) VADJ 3.5 (4 PLCS) MOUNTING HOLE 1 2 3 4 -V -V +V +V *Weight: 0.17kg max *Tolerance: ±1 *Dimensions in mm 32.0 1.26 3.0 MAX (LEAD) Mounting Method A. Vertical B. Horizontal *V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty. V-INFINITY LLC, 20050 SW 112th Ave., Tualatin, OR 97062 1-866-372-1258 www.v-infinity.com