EMERSON-NETWORKPOWER NFS110

Embedded Power for
Business-Critical Continuity
Rev. 11.2.09_69
NFS110 Series
1 of 5
NFS110 Series
Single & Quad output
Total Power:
Input Voltage:
# of Outputs:
80 - 110 W
85 - 264 Vac
120 - 370 Vdc
Single, quad
Special Features
•7.0 x 4.25 x 1.8 inch package
•Overvoltage and short circuit
protection
•110 W with 20 CFM
•Adjustable outputs
•EN55022, EN55011 conducted
emissions level B
•UL, VDE and CSA safety
approvals
•CE mark
•Available RoHS compliant
•2 year warranty
Safety
•VDE0805/EN60950/
•IEC950/IEC1010
File No. 10401-3336-0213
•Licence No. 4001467 7
•UL1950 File No. E132002
•CSA C22.2 No. 950
File No. LR41062C
Electrical Specifications
Output
Voltage adjustability:
+5.1 V o/p on multi’s
5.1 V single output
12 V single output
15 V single output
24 V single output
3.0%
3.0%
12 - 14 V
15 - 18 V
24 - 30 V
Line regulation:
±0.1% max.
Overshoot/undershoot:
LL to HL, FL
All outputs on all units
At turn-on
Temperature coefficient:
All outputs
±0.02%/°C
Overvoltage protection:
Multi o/p 5.1 V only
5.1 V single output
12 V single output
15 V single output
24 V single output
6.25 V ± 0.75 V
6.25 V ± 0.75 V
15.75 V ± 1.0 V
22 V ± 1.5 V
33 V ± 2.5 V
Output power limit:
Primary power limited
Minimum output current:
(See Note 13)
Pin max. 160 W
Pout min. 110 W
0A
Short circuit protection:
Burst mode operation
0%
Input
Input voltage range:
85 - 264 Vac
120 - 370 Vdc
Input frequency range:
47 - 440 Hz
Input surge current:
230 Vac
35 A
Safety ground leakage current:
110 Vac, 50 Hz
230 Vac, 50 Hz
0.2 mA, max.
0.4 mA, max.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
Embedded Power for
Business-Critical Continuity
Rev. 11.2.09_69
NFS110 Series
2 of 5
EMC Characteristics
Conducted emissions:
Radiated emissions:
ESD air:
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
Level B
Level A
Perf. criteria 1
ESD contact:
EN61000-4-2, level 4
Perf. criteria 1
Surge:
EN61000-4-3, level 3
Perf. criteria 1
Fast transients:
EN61000-4-4, level 3
Perf. criteria 1
Radiated immunity:
EN61000-4-5, level 3
Perf. criteria 2
Conducted immunity:
EN61000-4-6, level 3
Perf. criteria 1
Hold-up time:
110 Vac @ 80 W
110 Vac @ 110 W
230 Vac @ 80 W
230 Vac @ 100 W
35 ms
17 ms
140 ms
100 ms
Efficiency:
Multiple outputs
+5.1 V single
12 V and 15 V singles
24 V single
70% typical
70% typical
72% typical
75% typical
Isolation voltage:
Input/output
Input/chassis
3000 Vac
1500 Vac
Approvals and standards:
(see note 12)
VDE0805, EN60950, IEC950, IEC1010, UL1950, CSA C22.2 No. 950
Weight:
Singles
Multiple outputs
550 g (19.4 oz)
600 g (21.2 oz)
MTBF (@25 ºC):
MIL-HDBK-217E
125,000 hours min.
General Specifications
Environmental Specifications
Thermal performance:
Operating ambient
0° C to +70 °C
(See notes 9, 10)
Non-operating
-40 °C to +85 °C
0 °C to 50 °C convection cooled
80 W
+50 °C to +70 °C, convection cooled
Derate 2 W/°C
0 °C to +50 °C, 20 CFM forced air
110 W
+50 °C to +70 °C, 20CFM forced air
Derate 2.75 W/°C
Peak, 0 °C to +50 °C, max. 60 seconds 110W
Relative humidity:
Non-condensing
5 to 95% RH
Altitude:
Operating
10,000 feet max.
Non-operating
40,000 feet max.
5 - 500 Hz
2.4 G rms peak
Vibration:
(See Note 11)
Embedded Power for
Business-Critical Continuity
Rev. 11.2.09_69
NFS110 Series
3 of 5
Ordering Information
Output Currents
Output
Voltage
Max (1)
Peak (2)
Fan (3)
+5.1 V
8A
20 A
10 A
50 mV
± 2.0%
Ripple (4)
Total
Regulation (5)
+12 V
4.5 A
9A
5A
120 mV
± 3.0%
–12 V
0.5 A
1.5 A
1A
120 mV
± 3.0%
–5 V
0.5 A
1.5 A
1A
50 mV
± 3.0%
+5.1 V (IA)
8A
20 A
10 A
50 mV
± 2.0%
+24 V (IB)
3.5 A
4.5 A
4.5 A
240 mV
+10/–5.0%
+12 V
4.5 A
9A
5A
120 mV
± 3.0%
–12 V
0.5 A
1.5 A
1A
120 mV
± 3.0%
+5.1 V
8A
20 A
10 A
50 mV
± 2.0%
Notes
(6)
Model Numbers (13, 15, F)
NFS110-7601PJ (14)
NFS110-7602PJ (6, 14)
NFS110-7604PJ (14)
15 V
4A
7.5 A
5A
150 mV
± 4.0%
-15 V
0.5 A
1.5 A
1A
150 mV
± 3.0%
-5 V
0.5 A
1.5 A
1A
50 mV
± 3.0%
12 V
7A
9A
9A
120 mV
± 2.0%
NFS110-7612J (7,8)
15 V
5A
7.3 A
7.3 A
150 mV
± 2.0%
NFS110-7615J (7,8)
24 V
3.5 A
4.5 A
4.5 A
240 mV
± 2.0%
NFS110-7624J (7,8)
1 Convection cooled, 80 W maximum.
2 Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total
peak power must not exceed 110 W.
3 Forced air, 20 CFM at 1 atmosphere, 110 W maximum.
4 Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth
using a 12 inch twisted pair terminated with a 47 µF capacitor.
5 Total regulation is defined as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits and output voltages adjusted
to their factory settings.
6 To achieve stated regulation on the 24 V output on the NFS110-7602PJ, the
following load condition must be true: IA / IB ≤ 5, where:
IA = +5.1 V output current, and
IB = +24 V output current
The +24 V output will maintain ±5.0% regulation under the following
additional condition: IA ≤ 5 A.
7 Single output models have floating outputs which may be referenced as
either positive or negative. Higher voltage supplies may be adjusted over a
wide output voltage range, as long as the total output power does not exceed
80 Watts (natural convection) or 110 Watts (forced air).
8 Power fail detect not available on single output models.
9 Derating curve is application specific for ambient temperatures >50 °C,
for optimum reliability no part of the heatsink should exceed 90 ºC and no
semiconductor case temperature should exceed 100 ºC.
10 Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
11 Three orthogonal axes, random vibration, 10 minute test for each axis.
12 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
13 Recommend a minimum load of 11 W to achieve the design MTBF. See the
derating curve on page 4.
14 Power failure detec is optional by including the suffix “P” to the model
number.
15 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
16 NOTICE: Some models do not support all options. Please contact your
local Emerson Network Power representative or use the on-line model
number search tool at http://www.PowerConversion.com to find a suitable
alternative.
Transient Response
NFS110-7601PJ
+5.1 V (7.5 A to 10 A)
+12 V (2.5 A to 5 A)
-12 V (0.5 A to 1 A)
-5 V (0.5 A to 1 A)
150 mV peak, 1 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
NFS110-7602PJ
+5.1 V (7.5 A to 10 A)
+24 V (1.5 A to 3 A)
+12 V (2.5 A to 5 A)
-12 V (0.5 A to 1 A)
150 mV peak, 1 ms recovery
300 mV peak, 1 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
NFS110-7604PJ
+5.1 V (7.5 A to 10 A)
+15 V (2.5 A to 5 A)
-15 V (0.5 A to 1 A)
-5 V (0.5 A to 1 A)
150 mV peak, 1 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
NFS110-7605J
+5.1 V (10 A to 20 A)
250 mV peak, 1 ms recovery
NFS110-7612J:
+12 V (4.5 A to 9 A)
360 mV peak, 1 ms recovery
NFS110-7615J
+15 V (3.65 A to 7.3 A)
450 mV peak, 1 ms recovery
NFS110-7624J
+24 V (2.25 A to 4.5 A)
720 mV peak, 1 ms recovery
Embedded Power for
Business-Critical Continuity
Rev. 11.2.09_69
NFS110 Series
4 of 5
OPTIONAL POWER FAIL DETECT TIMING DIAGRAM
AC (J1) mating connector
Molex 09-50-3051 or Molex 09-91-0500 mating connector with 2478
or equivalent crimp terminals.
Power fail detect signal (Note 8)
AC INPUT
4.75V
HIGH
DC (J2) mating connector
Molex 09-50-3131 or Molex 09-91-1300 mating connector with 2478
or equivalent crimp terminals.
PFD SIGNAL
50ms ≤ T1 ≤ 200ms
T2 will vary with line and load
T3 ≥ 3ms
Pout: 110W
PFD output is an open collector which
will sink ≤ 40mA in the low state.
4.75V
5V OUTPUT
3.5V MIN
LOW
0-0.4 MAX
T3
T1
T2
0.475
0.010
(12.07)
DERATING CURVE (See Notes 9, 10)
1.80 (45.72) MAX
1.00 0.005
(25.4)
Output Power (Watts)
110W
0.050 0.020
(1.27)
80W
PIN 1
Voltage Adjust
Optional
Power Fail
Detect Circuit
(Key = Pin 2)
4.250
0.020
(107.95)
20 CFM FORCED AIR COOLING
6-32 UNC
(4PL)
1.55 0.005
(39.37)
3.35 0.015 (85.09)
NATURAL
CONVECTION
COOLING
J2
Pin 1
PIN 1
L1
11W
J1
C6
F1
11W MINIMUM LOAD REQUIRED AT 230VAC
0W
0.156
DIA. HOLE
(4PL)
0C
10C
7.00 0.020 (177.8)
ALL DIMENSIONS IN INCHES (mm)
Mechanical Notes:
A Metallic or non-metallic stand-offs (maximum diameter 5.4mm) can be used in all four mounting holes
without effecting safety approval.
B The ground pad of the mounting hole near J1, allows system grounding through a metal stand-off to
the system chassis.
C The heat sink is grounded, and allows system grounding by mechanical connection to the system
chassis.
D The supply must be mechanically supported using the PCB mounting holes and may be additionally
supported by the heatsink mounting holes.
E It is always advisable to attach the power supply heat sink to another thermal dissipator (such as a
chassis or finned heatsink etc). The resulting decrease in heat sink mounted component temperatures
will improve power supply lifetime.
F A standard L-bracket and cover is available for mounting which contains all screws, connectors and
necessary mounting hardware. The kit is available, order part number “NFS110CJ”­­.
20C
30C
40C
50C
60C
70C
Pin Connections
5A, 250 VAC
6.50 0.005 (165.1)
0.250
0.010
(6.35)
40W
T1
T1
3.750
0.005
(95.25)
0.250
0.010
(6.35)
55W
J1
-7601PJ
-7602 P
-7604PJ
Singles
Pin 1
AC Ground
AC Ground
AC Ground
AC Ground
Pin 2
AC Neutral
AC Neutral
AC Neutral
AC Neutral
Pin 3
AC Line
AC Line
AC Line
AC Line
Pin 1
+5.1 V
+5.1 V
+5.1 V
Vout
Pin 2
+5.1 V
+5.1 V
+5.1 V
Vout
J2
Pin 3
+5.1 V
+5.1 V
+5.1 V
Pin 4
Return
Return
Return
Vout
Return
Pin 5
Return
Return
Return
Return
Pin 6
Return
Return
Return
Return
Pin 7
Return
Return
Return
Return
Pin 8
+12 V
+12 V
+15 V
Vout
Pin 9
+12 V
+12 V
+15 V
Vout
Pin 10
PFD
PFD
PFD
N/C
Pin 11
-12 V
-12 V
-15 V
N/C
-5 V
+24 V
Pin 12
Pin 13
Removed for Key
N/C = no connection
-5 V
N/C
Embedded Power for
Business-Critical Continuity
­Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone:+1 760 930 4600
Facsimile: +1 760 930 0698
Rev. 11.2.09_69
NFS110 Series
5 of 5
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone:+44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone:+852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.PowerConversion.com
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2009 Emerson Electric Co.