ARTESYN CL40-7616

CL40 SERIES
Single and triple output
Recommended for new design-ins
•
•
•
•
•
•
•
The CL40 series is a family of 40W (50W peak) external switching power
supplies. The CL40 enables the system specifier to optimise the design for
several reasons. Firstly, because the power supply offers pre-approved SELV
(Safety Extra Low Voltage) outputs, the submission of the apparatus for safety
approval is simplified. This represents a significant saving of time and money.
Secondly, the task of integrating the power supply into the mechanical design is
eliminated, presenting further savings in time and money by ensuring a shorter
and simpler design cycle. This means that your product gets to market faster.
These advantages are complemented by universal input, CE mark, IEC950, UL,
CSA, VDE and BABT approvals, to complete a worldwide packaged power
solution suitable for a wide variety of low power, desktop applications.
[ 2 YEAR WARRANTY ]
SPECIFICATION
85VAC to 264VAC universal input range
Pre-approved SELV power solution
Up to 40W continuous output power
Up to 50W peak output power
UL, CSA, VDE and BABT approved
VDE0871-A conducted noise performance
Stand alone "listed" equipment
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS
OUTPUT SPECIFICATIONS
Line regulation
LL to HL, FL
Single outputs
Multi's: +5.1V output
Multi's: aux. outputs
±0.2%
±0.2%
±1.0%
Total regulation
NL to FL (Note 5)
Single outputs
Multi's: +5.1V output,
Multi's: aux. outputs
±5.0%
±5.0%
See table
Overshoot/undershoot
At turn-on
Transient response
(Single output model)
+5.1V output
(50% FL to
100% FL step)
Radiated emissions
EN55022, EN55011, FCC
Conducted emissions
EN55022, EN55011, FCC
Electrostatic discharge EN61000-4-2
Electrostat. air discharge IEC801-2
RF field susceptibility
IEC801-3
Electrical fast
EN61000-4-4
transients/bursts
Surge susceptibility
EN61000-4-5
Level B
Level A
Level 4
Level 3
Level 3
Level 3
Level 3
10% max.
GENERAL SPECIFICATIONS
±250mV max. dev.,
1ms recovery to 1%
Temperature coefficient All outputs
Overvoltage protection
+5.1V output only
Output power limit
Primary power limited
Short Circuit Protection
±0.02%/°C
6.25V ±0.75V
90W Pin max.
50W Pout min.
Continuous with
auto-restart
Hold-up time
110VAC
230VAC
Efficiency
110VAC and 230VAC
Isolation voltage
Input/output
Input/chassis
Switching frequency
Variable
Approvals and
standards
12ms
110ms
70% typical
3000VAC
1500VAC
20kHz to 70kHz
VDE0805, EN60950
IEC950, IEC1010, UL1950
BABT, CSA C22.2 No. 950
INPUT SPECIFICATIONS
Case material
Input voltage range
Note 1
ABS plastic
85 to 264VAC
Material flammability
Input frequency range
UL94V-0
47 to 440Hz
Weight
Input surge current
Safety ground
leakage current
110VAC
230VAC
110VAC, 60Hz
230VAC, 50Hz
12A max.
30A max.
0.2mA
0.4mA
MTBF
800g (28oz)
MIL-HDBK-217E
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating
0°C to +40°C
Non-operating
–40°C to +85°C
0°C to 40°C ambient
40W
Peak (0°C to 40°C, max. 60s)
50W
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
Vibration, 5Hz to 500Hz See Note 8
PAGE 1
100,000 hours min.
5% to 95% RH
10,000 feet max.
40,000 feet max.
2.4G rms (approx)
AC/DC POWER SUPPLIES
|
40W AC/DC
40 Watt
AC/DC external power supplies
OUTPUT CURRENT
OUTPUT
VOLTAGE
(1)
RIPPLE
MAX
(2)
PEAK
(4)
(3)
TOTAL
REGULATION
(5)
MODEL NUMBER
+5.1V (A)
3.0A
5.0A
50mV
±5.0%
+12.0V (B)
1.7A
3.0A
120mV
-3.0%, +7.0%
–12.0V
0.35A
1.0A
120mV
±5.0%
+5.1V (A)
3.0A
5.0A
50mV
±5.0%
+15.0V (B)
1.3A
3.0A
150mV
-2.0%, +5.0%
–15.0V
0.35A
1.0A
150mV
±5.0%
+5.1V
5.0A
5.0A
50mV
±6.0%
CL40-7605
CL40-7605J
(7)
+12.0V
3.3A
4.0A
120mV
±5.0%
CL40-7612
CL40-7612J
(7)
+13.5V
3.0A
3.7A
130mV
±5.0%
CL40-7613
+15.0V
2.7A
3.3A
150mV
±5.0%
CL40-7615
CL40-7615J
(7)
+16.5V
2.4A
3.0A
160mV
±5.0%
CL40-7616
+24.0V
1.6A
2.0A
240mV
±5.0%
CL40-7624
CL40-7624J
(7)
Notes
1 For 230VAC operation a minimum output load of 4 Watts is required.
2 Natural convection cooling, 40W maximum.
3 Peak output current lasting less than 60 seconds with duty cycle less than
10%. During peak loading outputs may go outside of regulation limits.
Peak total power must not exceed 50W.
4 Figures are peak-to-peak. Output noise is measured across a 20MHz
bandwidth using a 12” twisted pair terminated with a 47µF capacitor.
5 Total regulation is defined as the static output regulation at 25°C, including
initial tolerance, load currents within stated limits, and output voltages
adjusted to their factory settings. Also, for ‘B’ output stated regulation:
I(A)/I(B)<5.
6 The standard CL40 is IEC950/VDE0805 approved as a stand-alone power
supply. The plastic case incorporates an IEC 320 inlet receptacle.
No input cable is supplied in Europe as standard.
An input cable is supplied to customers in the US only. To order add
the suffix ‘I’ to the end of the model number, e.g. CL40-7605I.
In order to have a stand-alone power supply fully UL and CSA listed (as
opposed to certified or recognised) it is required that the manufacturer provide an approved input cable with the power supply.
7 The standard output connector is a DIN41524 five-pin plug. As an alternative single output models can be supplied with a 2.5mm battery eliminator
jack. To order this option add the suffix “J” to the model number.
Example: CL40-7612J. See the table above for availability.
8 Three orthogonal axes random vibration, 10 minute test for each axis.
72
(1829)
5
CL40-7610
PIN CONNECTIONS
PIN NUMBER
SINGLES
-7608
-7610
1
+VOUT
+5.1V
+5.1V
2
+VOUT
+12V
+15V
3
Return
Return
Return
4
Return
–12V
–15V
5
Return
Return
Return
2.5mm BATTERY ELIMINATOR JACK
(SUFFIX 'J')
- NEGATIVE
6.5
(165)
+ POSITIVE
3.85
(98)
1
4
CL40-7608
2
3
STANDARD OUTPUT CONNECTION
(DIN 41524 FIVE PIN PLUG)
International Safety Standard Approvals
geprüfte
Sicherhelt
2.60
(66)
VDE0805/EN60950, IEC950, IEC1010
File No. 10401-3336-1062 Licence No. 1062
ALL DIMENSIONS ARE INCHES (mm)
DS_CL40_19980401.PDF
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062/LR50913/LR101320
Certificate No. PS/603191