EMERSON-NETWORKPOWER NFS110

Embedded Power for
Business-Critical Continuity
Rev.02.16.07
NFS110 Series
1 of 4
NFS110 Series
Single and
quad output
Total Power:
80 - 110W
Input Voltage: 85 - 264VAC
120 - 370VDC
# of Outputs: Single, quad
Special Features
• 7.0 x 4.25 x 1.8 inch package
• Overvoltage and
short circuit protection
• 110 W with 20 CFM
• Adjustable outputs
• EN55022, EN55011
conducted emissions level B
• UL, VDE and CSA
safety approvals
• CE mark
• Available RoHS compliant
• 2 year warranty
Safety
VDE0805/EN60950/
IEC950/IEC1010
File No. 10401-3336-0213
Licence No. 40014677
UL1950 File No. E136005
CSA C22.2 No. 950
File No. LR41062C
The NFS110 series is a 110 W universal input ac-dc power supply
on a 7 x 4.25 inch card. The NFS110 series has four single and
three quad output models and has proven itself to be highly
reliable and versatile product for a wide range of communication
and industrial applications, with a very high peak current
capability on each output for drive and motor applications. The
NFS110 provides 80 W of output power with free air convection
cooling which can be boosted to 110 W with 20 CFM of air.
Standard features include overvoltage and short circuit
protection. The series, with full international safety approval and
the CE mark, meets conducted emissions EN55022 level B. The
NFS110 series is designed for use in low power data networking,
computer, telecom and industrial applications such as servers,
thermal printers, storage devices, vending machines and POS
equipment.
Embedded Power for
Business-Critical Continuity
Rev.02.16.07
NFS110 Series
2 of 4
Specifications
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Voltage adjustability
+5.1 V o/p on multi’s
5.1 V single output
12 V single output
15 V single output
24 V single output
Line regulation
LL to HL, FL
All outputs on all units
Overshoot/undershoot
At turn-on
0%
Temperature coefficient
All outputs
±0.02%/°C
Overvoltage protection
Multi o/p 5.1 V only
5.1 V single
12 V single
15 V single
24 V single
Output power limit
Primary power
limited
Minimum output current
(See Note 13)
Short circuit protection
±3.0%
±3.0%
12-14 V
15-18 V
24-30 V
Hold-up time
110 Vac @ 80 W
110 Vac @ 110 W
230 Vac @ 80 W
230 Vac @ 110 W
Efficiency
Multiple outputs
+5.1 V single
12 V and 15 V singles
24 V single
Isolation voltage
Input/output
Input/chassis
Switching frequency
At 100 Watts output
At zero load
±0.1% max.
6.25 V ±0.75 V
6.25 V ±0.75 V
15.75 V ±1.0 V
22 V ±1.5 V
33 V ±2.5 V
Pin max. 160 W
Pout min. 110 W
Approvals and
standards
(See Note 12)
70% typical
70% typical
72% typical
75% typical
3000 Vac
1500 Vac
20-70 kHz
100-250 kHz
VDE0805, EN60950, IEC950
IEC1010, UL1950
CSA C22.2 No. 950
Weight
Singles
Multiple outputs
550 g (19.4 oz)
600 g (21.2 oz)
MTBF (See Note 9)
MIL-HDBK-217E
125,000 hours
0A
Burst mode operation
35 ms
17 ms
140 ms
100 ms
ENVIRONMENTAL SPECIFICATIONS
INPUT SPECIFICATIONS
Input voltage range
85-264 Vac
120-370 Vdc
Input frequency range
Thermal performance
(See Notes 9, 10)
47-440 Hz
Input surge current
230 Vac
35 A
Safety ground
leakage current
110 Vac, 50 Hz
230 Vac, 50 Hz
0.2 mA, max.
0.4 mA, max.
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
Level B
Level A
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 2
Perf. criteria 1
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
Operating, see curve
0 °C to +70 °C
Non-operating
–40 °C to +85 °C
0 °C to +50 °C,
80 W
amb. convection cooled
+50 °C to +70 °C,
Derate 2 W/°C
amb. convection cooled
0 °C to +50 °C,
110 W
20 CFM forced air
+50 °C to +70 °C,
Derate
20 CFM forced air
2.75 W/°C
Peak, 0 °C to +50 °C,
110 W
max. 60 seconds
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
Vibration (See Note 11)
5-500 Hz
5% to 95% RH
10,000 feet max.
40,000 feet max.
2.4 G approx.
Embedded Power for
Business-Critical Continuity
Rev.02.16.07
NFS110 Series
3 of 4
Specifications Contd.
OUTPUT CURRENTS
OUTPUT
VOLTAGE
MAX (1)
PEAK (2)
FAN (3)
RIPPLE (4)
TOTAL
REGULATION (5)
MODEL NUMBERS (13,14,F)
+5.1 V
8A
20 A
10 A
50 mV
±2.0%
NFS110-7601PJ
+12 V
4.5 A
9A
5A
120 mV
±3.0%
–12 V
0.5 A
1.5 A
1A
120 mV
±3.0%
–5 V
0.5 A
1.5 A
1A
50 mV
±3.0%
+5.1 V (IA)
8A
20 A
10 A
50 mV
±2.0%
+24 V (IB) (6)
3.5 A
4.5 A
4.5 A
240 mV
+10/–5.0%
+12 V
4.5 A
9A
5A
120 mV
±3.0%
–12 V
0.5 A
1.5 A
1A
120 mV
±3.0%
+5.1 V
8A
20 A
10 A
50 mV
±2.0%
3
4
5
6
7
8
9
10
11
12
13
14
15
NFS110-7604PJ
+15 V
4A
7.5 A
5A
150 mV
±3.0%
–15 V
0.5 A
1.5 A
1A
150 mV
±3.0%
–5 V
0.5 A
1.5 A
1A
50 mV
±3.0%
5.1 V
16 A
22 A
20 A
50 mV
±2.0%
NFS110-7605J (7,8)
12 V
7A
9A
9A
120 mV
±2.0%
NFS110-7612J (7,8)
15 V
5A
7.3 A
7.3 A
150 mV
±2.0%
NFS110-7615J (7,8)
24 V
3.5 A
4.5 A
4.5 A
240 mV
±2.0%
NFS110-7624J (7,8)
Notes
1
2
NFS110-7602PJ (6)
Convection cooled, 80 W maximum.
Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total
peak power must not exceed 110 W.
Forced air, 20 CFM at 1 atmosphere, 110 W maximum.
Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth
using a 12 inch twisted pair terminated with a 47 μF capacitor.
Total regulation is defined as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits and output voltages adjusted
to their factory settings.
To achieve stated regulation on the 24 V output on the NFS110-7602PJ, the
following load condition must be true: IA / IB ≤ 5, where:
IA = +5.1 V output current, and
IB = +24 V output current
The +24 V output will maintain ±5.0% regulation under the following additional
condition: IA ≤ 5 A.
Single output models have floating outputs which may be referenced as either
positive or negative. Higher voltage supplies may be adjusted over a wide
output voltage range, as long as the total output power does not exceed 80
Watts (natural convection) or 110 Watts (forced air).
Power fail detect not available on single output models.
Derating curve is application specific for ambient temperatures >50 °C, for
optimum reliability no part of the heatsink should exceed 90 ºC and no
semiconductor case temperature should exceed 100 ºC.
Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
Three orthogonal axes, random vibration, 10 minute test for each axis.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Artesyn Technologies recommends a minimum load of 11 W to achieve the
design MTBF. See the derating curve on page 3.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE
RoHS 5/6 (non Pb-free) compliant versions may be available on special request,
please contact your local sales representative for details.
NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
TRANSIENT RESPONSE
NFS110-7601PJ
+5.1 V (7.5 A to 10 A)
+12 V (2.5 A to 5 A)
-12 V (0.5 A to 1 A)
-5 V (0.5 A to 1 A)
NFS110-7602PJ
+5.1V (7.5 A to 10 A)
+24 V (1.5 A to 3 A)
+12 V (2.5 A to 5 A)
-12 V (0.5 A to 1 A)
NFS110-7604PJ
+5.1 V (7.5 A to 10 A)
+15 V (2.5 A to 5 A)
-15 V (0.5 A to 1 A)
-5 V (0.5 A to 1 A)
150 mV peak,
1 ms recovery
100 mV peak,
0.5 ms recovery
100 mV peak,
0.5 ms recovery
100 mV peak,
0.5 ms recovery
150 mV peak,
1 ms recovery
300 mV peak,
1 ms recovery
100 mV peak,
0.5 ms recovery
100 mV peak,
0.5 ms recovery
150 mV peak,
1 ms recovery
100 mV peak,
0.5 ms recovery
100 mV peak,
0.5 ms recovery
100 mV peak,
0.5 ms recovery
NFS110-7605J
+5.1 V (10 A to 20 A)
250 mV peak,
1 ms recovery
NFS110-7612J
+12 V (4.5 A to 9 A)
360 mV peak,
1 ms recovery
NFS110-7615J
+15 V (3.65 A to 7.3 A)
450 mV peak,
1 ms recovery
NFS110-7624J
+24V (2.25 A to 4.5 A)
720 mV peak,
1 ms recovery
Embedded Power for
Business-Critical Continuity
Rev.02.16.07
NFS110 Series
4 of 4
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
[email protected]
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.