EMERSON-NETWORKPOWER NFS40SERIES

Embedded Power for
Business-Critical Continuity
Rev.12.12.08_118
NFS40 Series
of 4
NFS40 Series
SIngle and
triple output
Total Power: 40 - 50W
Input Voltage: 85 - 264VAC
120 - 370VDC
# of Outputs:
Single, triple
Electrical Specifications
Special Features
• 5.0 x 3.0 x 1.2 inch package
(1U applications)
• Industry standard package
• Overvoltage and
short circuit protection
• 40 W with free air convection
• 50 W with 20 CFM forced air
• EN55022, EN55011
conducted noise level A
• UL, VDE and CSA
safety approvals
• Available RoHS compliant
• 2 year warranty
Input
Voltage adjustability:
+5 V output on triples
Vout on singles
±5.0%
±5.0%
Line regulation:
LL to HL, FL
Main output
Auxiliary outputs
±0.2%
±1.0%
Load regulation:
FL to NL
Main output
Auxiliary outputs
±2.0%
±5.0%
Transient response:
+5 V (1.5 - 3 A)
± 120 mV max. dev.
500 µs recovery
Temperature coefficient:
All outputs
±0.02%/°C
Overvoltage protection:
+5 V output
S3.15 A, 250 Vac In live and neutral
Output power limit:
Primary power limited
90 W input power limit
Short circuit protection:
Single outputs
Multiple outputs
Continuous
Short term
Universal input
85-264 Vac
120-370 Vdc
Output
Input voltage range:
Input frequency range:
Safety
• VDE0805/EN60950/
• IEC950/IEC1010
• File No. 10401-3336-0044
• License No. 2559
• UL1950 File No. E136005
• CSA C22.2 No. 950
• File No. LR41062C
47-440 Hz
Max. input surge current:
132 Vac, cold start
264 Vac, cold star
12 A max.
24 A max.
Safety ground leakage current:
110 Vac, 60 Hz
230 Vac, 50 Hz
0.13 mA, max.
0.32 mA, max.
Embedded Power for
Business-Critical Continuity
Rev.12.12.08_118
NFS40 Series
of 4
Specifications
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
EMC Charateristics (11, 12)
Conducted emissions:
EN55022, FCC part 15
Level B
Radiated emissions:
EN55022
Level A
ESD air:
EN61000-4-2, level 3
Perf. criteria 1
ESD contact:
EN61000-4-2, level 4
Perf. criteria 1
Surge:
EN61000-4-2, level 3
Perf. criteria 1
Fast transients:
EN61000-4-4, level 3
Perf. criteria 1
Radiated immunity:
EN61000-4-3, level 3
Perf. criteria 2
Conducted immunity:
EN61000-4-6, level 3
Perf. criteria 2
110 Vac, 40 W
230 Vac, 40 W
14 ms
110 ms
General Specifications
Hold-up time:
Efficiency:
Isolation voltage:
70% typical
Input/output
Input/chassis
3000 Vac
1500 Vac
Switching frequency:
Variable
Approvals and standards: (see VDE0805, EN60950, IEC950, IEC1010,
Notes 9, 13)
UL1950, CSA C22.2 No. 950
Weight:
280 g (9.88 oz)
MTBF demonstrated:
MIL-HDBK-217E
170,000 hours
Environmental Specifications
Thermal performance:
Operating
0° C to +70 °C
(See notes 8, 10)
Non-operating
-40 °C to +85 °C
50 °C ambient temp.,
convection cooled
40 W
Forced air cooling
50 W @ 20 CFM
+50 °C to +70 °C ambient
Derate linearly to 50% load
Peak (60 seconds)
60W
Relative humidity:
Non-condensing
5 to 80% RH
Altitude:
Operating
10,000 feet max.
Non-operating
40,000 feet max.
5-500 Hz
2.4 G rms peak
Vibration (See Note 11):
Embedded Power for
Business-Critical Continuity
Ordering Information
Output
Voltage
Output Currents
Ripple (4)
Total
Regulation (5)
Fan (3)
Model Numbers (13, 14, F)
Max (1)
Peak (2)
+5.1 V (A)
3A
7A
5A
50 mV
±2.0%
+12 V (B)
2A
3A
2A
120 mV
±5.0%
–12 V (C)
0.35 A
1A
0.5 A
120 mV
±5.0%
+5.1 V (A)
4A
7A
5A
50 mV
±2.0%
+12 V (B)
0.35 A
1A
0.5 A
120 mV
±5.0%
-12 V (C)
0.35 A
1A
0.5 A
120 mV
+5.0%
+5.1 V (A)
3A
7A
5A
50 mV
±2.0%
+12 V (B)
2A
3A
2A
120 mV
±5.0%
-5.0 V (C)
0.35 A
1A
0.5 A
50 mV
±5.0%
+5.1 V (A)
3A
7A
5A
50 mV
±2.0%
+15 V (B)
2A
2.5 A
2A
150 mV
±10.0%/-3.0%
–15 V (C)
0.35 A
1A
0.5 A
150 mV
±5.0%
3.3 V
6A
12 A
8A
100 mV
±2.0%
NFS40-76S3J
+5.1 V
6A
12 A
8A
100 mV
±2.0%
NFS40-7605J
+12.0 V
3.3 A
5A
4A
120 mV
±2.0%
NFS40-7612J
+15.0 V
2.6 A
4A
3.3 A
150 mV
±2.0%
NFS40-7615J
+24.0 V
1.6 A
2.5 A
2A
240 mV
±2.0%
NFS40-7624J
Notes
1 Natural convection cooled, 40 W maximum.
2 Peak output current lasting less than 30 seconds with duty cycle less than 10%.
During peak loading, outputs may go outside of total regulation limits. Peak
total power must not exceed 60 W.
3 Forced air, 20 CFM at 1 atmosphere, 50 W maximum.
4 Figure is peak-to-peak. Output noise is measured across a 50 MHz bandwidth
using a 12 inch twisted pair, terminated with a 47 µF capacitor.
5 Total regulation is defined as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits, load currents within stated
limits, and output voltages adjusted to their factory settings. Also, 0.25<I(A)/
I(B)<5.0 to maintain stated regulation. This does not apply to the NFS40-7628J
power supply as it has regulated auxiliary outputs.
6 A minimum load of 0.5 A is required on the +5 V output to obtain full current
from the negative output.
7 The NFS40 offers the possibility of power sharing between outputs. Consult
factory for details.
8 Derating curve is application specific for ambient temperatures >50 °C, for
optimum reliability no part of the heatsink should exceed 110 oC and no
semiconductor case temperature should exceed 115 oC.
9 A 4 W minimum load is recommended to achieve the design MTBF.
10 Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
11 Three orthogonal axes, sweep at 1 octave/minute, 5 minute dwell at four major
resonances.
12 The NFS40-7628J has separately linear regulated +12 V and -12 V outputs. The
loading conditions in Notes 5 and 6 do not apply.
13 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
14 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
15 NOTICE: Some models do not support all options. Please contact your local
Emerson Network Power representative or use the on-line model number
search tool at http://www.powerconversion.com to find a suitable alternative.
Rev.12.12.08_118
NFS40 Series
of 4
NFS40-7608J (5,6)
NFS40-7628J (12)
NFS40-7607J (5,6)
NFS40-7610J (5,6)
Pin Connections
J1
-7608J, -7628J
-7607J
-7610J
SINGLES
Pin 1
AC Live
AC Live
AC Live
AC Line
Pin 2
AC Neutral
AC Neutral
AC Neutral
AC Neutral
Pin 1
+12 V
+12 V
+15 V
+Vout
Pin 2
+5.1 V
+5.1 V
+5.1 V
+Vout
Pin 3
+5.1 V
+5.1 V
+5.1 V
+Vout
Pin 4
Return
Return
Return
Return
Pin 5
Return
Return
Return
Return
Pin 6
-12 V
-5 V
-15 V
Return
J2
P1(c)
Pin 1
Safety Ground
DERATING CURVE
Output Power (Watts)
50W
20 CFM FORCED AIR COOLING
40W
NATURAL
CONVECTION
COOLING
0C
10C
20C
30C
40C
25W
20W
50C
60C
70C
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
0.156 (3.96) Dia.
(4 Places)
NON-METALLIC
STAND-OFF
(SEE NOTE A)
J1
3.00
(76.2)
­Americas
5.00
(127.00)
C5
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone:+1 760 930 4600
Facsimile: +1 760 930 0698
MAXIMUM
COMPONENT
HEIGHT 1.2 inches
Europe (UK)
Q1
1
~
N
~
L
F1
2.550
(64.8)
T1
F 3.15A, H 250VAC
0.22
(5.59)
0.22 (5.59)
4.55
(115.8)
ALL DIMENSIONS IN INCHES (mm)
Mechanical Notes
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone:+44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
J2
P1 (SEE NOTE C)
Rev.12.12.08_118
NFS40 Series
of 4
A In order to meet safety requirements, a non-metallic stand-off is mandatory for one hole as specified in the mechanical
drawing above.
B The ground pad of the mounting hole near P1 allows system grounding through a metal stand-off.
C To improve conducted noise, the ground pad of the mounting hole near the output connector should be connected with
the ground pad of the mounting hole near P1. Use metal stand-offs attached to a common metal chassis. This connection
also significantly attenuates common mode noise.
D A standard L-bracket and cover is available for mounting which contains all screws, connectors and necessary mounting
hardware. Order part number ‘NFS40 COVER KIT’.
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone:+852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.