HITRON HAS50

H HiTRON
CHASSIS-MOUNT UNIVERSAL INPUT AC-DC ENCAPSULATED
MODULAR POWER SUPPLIES 50 WATTS DUAL & TRIPLE OUTPUT
HAS50-D & HAS50-T SERIES
FEATURES:
CHASSIS-MOUNT AC/DC MODULAR
POWER SUPPLIES
UNIVERSAL AC INPUT RANGE
MEET UNIVERSAL SAFETY STANDARDS
EMI MEETS CISPR PUB.22/FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: 90-264Vac typical.
Nominal: 115/230Vac.
Input Frequency: 47-63 Hz. (Nominal 50/60Hz.).
Input Current: 0.76A @115Vac./0.39A @230Vac typical.
Inrush Current: 4.8A(rms) or 34A(peak)@230Vac typical.
Input Fuse: Use internal fuse.
Dielectric Withstand: Meet IEC60950.
3,000Vac-Output/Input.
1,500Vac-Input/GND.
500Vac-Output/GND.
EMI: Meet CISPR PUB. 22/FCC Class B.
Hold-up time: 18 mS @115Vac, 82mS @230Vac typical.
Earth Leakage: Less than 0.46mA @230Vac.
Remote ON/OFF:
ON(Enable)=Open.
OFF(Disable)=Short.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 50 Watts typical.
Line Regulation: Various with output voltage.
±0.1-0.5% typical.
Load Regulation: Various with output voltage.
Main VO1 ± 1-2% typical.
Aux.VO2 ± 3-5% typical. (stacked on)
Aux.VO3 ± 2-3% typical. (P.R.)
Noise & ripple: 1.0% typical peak to peak.
OVP: Built-in on main output VO1.
Adjustability: Available at main output VO1.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
Typical 125-150% of rating output load.
Con2sult the factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency: 78-83% typical various with output voltage.
Switching Frequency: 68K Hz.
Circuit Topology: Fixed Frequency Flyback circuit.
Transient Response: Peak deviation on 200-220mV,
Recovery time <3mSec.@ 25%step load change.
Case: Impact resistant thermo-plastic enclosure.
Safety Standard: EN60950/ UL1950 Class I or Class II.
Power Density: 3.6 Watts. / Cubic inch.
MTBF: 110,000Hrs. Mil Std 217, 25°C.
Operating Temperature: -10°C to +75°C range.
–10°C to +50°C @ full load without derating.
From+50°C derating linearly to half load @+75°C
(Refer to the Derating Chart).
Storage Temperature: -20°C to +85°C.
Temperature Coefficient: ±0.03% /°C.
Cooling: Convection cooling for +50°C @ full load.
At least 100LFM moving air is recommended
for full load >+50°C in a confined area.
Commercial Grade only.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load.
In application
Due to requests in market and advances in technology, specifications subject to change without notice.
-15-
OUTPUT VOLTAGE/ CURRENT RATINGS CHART
DUAL OUTPUT
MODEL NO.
HAS50-D050E
HAS50-D050I
HAS50-D120I
HAS50-D150K
HAS50-D033E
VO1 ★@
TYP.
VOLT.
3.0A
+5V
3.5A
+5V
2.0A
+12V
1.7A
+15V
3.5A
+3.3V
TYP
3.0A
2.0A
2.0A
1.7A
3.0A
VO1 @
TYP.
4.0A
4.0A
4.0A
3.5A
3.5A
3.5A
3.5A
TYP.
2.0A
1.0A
0.8A
1.0A
0.8A
1.0A
0.5A
VO2●
VOLT.
-5V
+12V
-12V
-15V
-5V
TRIPLE OUTPUT
MODEL NO.
HAS50-T033EE
HAS50-T033II
HAS50-T033KK
HAS50-T050II
HAS50-T050KK
HAS50-T050IE
HAS50-T050MI
VO3 ●
VO2 †
TYP.
VOLT.
VOLT.
0.5A
+5V
-5V
0.5A
+12V
-12V
0.5A
+15V
-15V
0.5A
+12V
-12V
0.5A
+15V
-15V
0.5A
+12V
-5V
0.5A
+24V
-12V
"†" Stacked on main O/P.
"●" Installed with Post Regulator (P.R.).
★
VOLT.
+3.3V
+3.3V
+3.3V
+5.0V
+5.0V
+5.0V
+5.0V
Symbols: "★" OVP built-in.
"@" Adjustable.
Note: (1) Max. (maximum load) is the continuous operating load of each rail,
but the max. load of each rail can not be drawn from all outputs at the same time.
(2) Peak output, less than 60 Sec. with duty cycle <10%.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 378.0g (13.3 Oz.)
PIN ASSIGNMENT
PIN NO.
P1-L
P1-N
P1-G
P2-1
P2-2
P2-3
P2-4
P2-5
P2-6
DUAL
O/P(+VO2)
L
N
G
REMOTE
ON/OFF
NC
+VO2
VO1
DC COM
DC COM
DUAL
O/P(-VO2)
L
N
G
REMOTE
ON/OFF
-VO2
NC
VO1
DC COM
DC COM
DERATING CHART
-16-
TRIPLE
O/P
L
N
G
REMOTE
ON/OFF
-VO3
+VO2
+VO1
DC COM
DC COM