60 Watts Total Power: Input Voltage: LPT60 Series # of Outputs: 60-80 Watts 85-264 VAC 120-300 VDC Triple Electrical Specs Input Input range 85-264 VAC 120-300 VDC 47-440 Hz <18 A peak @ 115 VAC; <36 A peak @ 230 VAC, cold start @ 25°C 1.5 A max. (RMS) @ 115 VAC 70% typical at full load (60% for LPT61) FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted Frequency Inrush current Input current Efficiency EMI filter Special Features • • • • • • • • • • Safety ground leakage current Universal input 3” x 5” footprint Remote sense on main output Built-in EMI filter Low output ripple Adjustable main output Overvoltage protection Overload protection 110 KHz switching frequency LPX60 enclosure kit available <0.5 mA @ 50/60 Hz, 264 VAC input Output Maximum power Adjustment range Cross regulation Hold-up time Overload protection Environmental Overvoltage protection Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70°C Remote sense Electromagnetic susceptibility: designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 60 W for convection (LPT61, 35 W); 80 W with 30 CFM forced air (LPT61, 55 W) -5, +10% minimum ±2% on output 1; ±5% on outputs 2,3 20 ms @ 60 W load, 115 VAC nominal line Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating 5.7-6.7 VDC on main output LPT61: 3.6 to 4.6 VDC Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Humidity: Operating; non-condensing 5% to 95% Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5 Hz to 500 Hz, operational Storage temperature: -40° to 85°C Temperature coefficient: ±.04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions Safety VDE UL CSA NEMKO BABT CB CE 96 America’s (USA): 1-888-41-ASTEC 0805/EN60950 (IEC950) UL1950 CSA 22.2-234 Level 3 EN 60950/EMKO-TUE (74-sec) 203 EN60950/BS7002 Certificate and report Mark (LVD) Europe (UK): 44 (1384) 842-211 11774-3336-1255 (LC #86665) E132002 LR53982C P95100123 PS / 605273 1518, 1519, 1520 Asia (HK): 852-2437-9662 rev 12.01.01 AMERICAS EUROPE ASIA 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44(1384) 843-355 Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 LPT60 Series Ordering Information Model Number Output Voltage Minimum Load Maximum Load with Convection Cooling Maximum Load with 30 CFM Forced Air Peak Load1 Regulation2 Ripple P/P (PARD)3 LPT61 +3.3 V +5 V +12 V 0.7A 0A 0A 5A 2.5 A 0.5 A 8.5 A 3.0 A 1.0 A 9.5 A 3.3 A 1A ±2% ±2% ±5% 50mV 50mV 120mV LPT62 +5 V +12 V -12 V 0.7 A 0.3 A 0A 7A 3A 0.7 A 8A 3.5 A 1A 10 A 6A 1.5 A ±2% ±5% ±5% 50 mV 120 mV 120 mV LPT63 +5 V +15 V -15 V 0.7 A 0.3 A 0A 7A 2.8 A 0.7 A 8A 3.3 A 1A 10 A 4A 1.5 A ±2% ±5% ±5% 50 mV 150 mV 150 mV LPT64 +5 V +12 V -5 V 0.7 A 0.3 A 0A 7A 3A 0.7 A 8A 3.5 A 1A 10 A 6A 1.5 A ±2% ±5% ±5% 50 mV 120 mV 50 mV LPT65 +5 V +24 V +12 V 0.7 A 0.1 A 0A 7A 1.5 A 0.7 A 8A 2.0 A 1A 10 A 3A 1.5 A ±2% ±7% ±5% 50 mV 240 mV 120 mV LPT66 +5 V +24 V -12 V 0.7 A 0.1 A 0A 7A 1.5 A 0.7 A 8A 2.0 A 1A 10 A 3A 1.5 A ±2% ±7% ±5% 50 mV 240 mV 120 mV LPT67 +5 V +24 V -5 V 0.7 A 0.1 A 0A 7A 1.5 A 0.7 A 8A 2.0 A 1A 10 A 3A 1.5 A ±2% ± 7% ± 5% 50 mV 240 mV 50 mV 1. 2. 3. 4. Peak current lasting <30 seconds with a maximum 10% duty cycle. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. Minimum Loads are required. Power Derating Curve 80W Pin Assignments 30 CFM Forced Air Cooling Connector LPT61 LPT62 LPT63 LPT64 LPT65 LPT66 LPT67 SK1-1 SK1-3 Neutral Line Neutral Line Neutral Line Neutral Line Neutral Line Neutral Line Neutral Line SK2-1 SK2-2 SK2-3 SK2-4 SK2-5 SK2-6 SK201-1 SK201-2 5V +12 V 3.3 V +5 V 3.3 V +5 V Common Common Common Common +12V -12 V +Sense +Sense -Sense -Sense +15 V +5 V +5 V Common Common -15 V +Sense -Sense +12 V +5 V +5 V Common Common -5 V +Sense -Sense +24V +5 V +5 V Common Common +12 V +Sense -Sense +24V +5 V +5 V Common Common -12 V +Sense -Sense +24V +5 V +5 V Common Common -5 V +Sense -Sense Mating Connectors AC Input: Molex 09-50-8031 (USA) 09-91-0300 (UK) PINS: 08-58-0111 DC Outputs: Molex 09-50-8061 (USA) 09-91-0600 (UK) PINS: 08-58-0111 Remote Sense: Molex 22-01-2025 PINS: 08-50-0114 Astec Connector Kit #70-841-006, includes all of the above. Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±.02”. 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 VAC input, 25°C unless otherwise stated. 6. Warranty: 1 year 7. Weight: 0.75 lb. / 0.34 kg 60W Output Power (Watts) 40W Natural Convection Cooling 20W 40W 30W 0W 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C TA – Ambient Temperature – °C 0.22" (5.6) 4.55" (115.6) M1 GND 3.00" (76.2) 2.55" (64.8) 1 SK 1 3 N 5.00" (127) M2 SK201 + _ 1 2 3 4 5 6 Remote Sense Connector Voltage Adj. Pot SK 2 L 0.15" (4) DIA (4 places) 1.65" (41.9) 0.12" (3) www.astec.com 97