Download

1W DC-DC Converter P1W-Series
●
●
●
●
●
●
●
●
SIL7 Dual Split Regulated Output
Low ripple and noise
Up to 3000 VDC isolation
MTBF > 2 MHours
Mobile applications
Portable equipments
Telecommunication instruments
Mixed analog / digital subsystems
Model selection guide
Typ
Input nominal
voltage
Output 2
voltage
[VDC]
[VDC]
P1W0505S
5
P1W1205S
12
P1W1505S
15
P1W2405S
24
Suffix: “H” for 3kV isolation voltage
Input
Voltage range
Filter
Isolation:
Rated voltage
Resistance
Capacitance
Output
Voltage accuracy
Voltage balance
(dual outputs)
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Line voltage regulation
Load voltage regulation
Temperature coefficient
Power
Output 2
current
[mA]
5.0
5.0
5.0
5.0
Efficiency typ. Capacitive
load
voltage
[VDC]
100
100
100
100
current
[mA]
5.0
5.0
5.0
5.0
1
2
4
5
6
7
Standard
Dual split
+V Input
-V Input
+V2 Output
Ground
+V1 Output
Omitted
65
67
67
69
General
Efficiency
Switching frequency
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
± 10%
Capacitors
1000 VDC, standard
3000 VDC suffix H
9
10 Ω
60 pF, typ.
± 2%, max.
± 1%
Short term
± 0.4% max.
± 0.3%
± 0.02% / °C
0.6W…1W max.
2 x 470
2 x 470
2 x 470
2 x 470
65 % to 69 %
100 kHz, typ.
-25 °C to +71 °C
90 °C, max.
-40 °C to +125 °C
None required
Up to 90%,
non-condensing
Free-air convection
Cooling
Physical
Dimensions
50 mVp-p, max.
[µF]
100
100
100
100
SIL
19.50 x 6.00 x 9.50 mm
2.5 g
non-conductive black plastic
Weight
Case material
Dimensions
6.0
19.5
Pin connections
Pin
[%]
3 kVDC
Dual split
+V Input
-V Input
Omitted
+V2 Output
Ground
+V1 Output
P1W0505S
PHI-CON
9.5
1
2
4
5
6
7
3.05
0.5
2.54
15.2
Life Support Policy: HY-LINE does not authorize the use of
any of its products for use in life support devices or systems
without the express written approval of an officer of the
Company. Life support systems are devices which support or
sustain life, and whose failure to perform, when properly used
in accordance with instructions for use provided in the
labeling, can be reasonably expected to result in significant
injury to the user. Rev: 11.04 f
0.5
0.25
1.25
0.5
All dimensions in mm
Tolerance ±0.25 mm
Page 1 of 1
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstraße 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]