IVO NE218.013AX01

Preset counters electronic
2 presets, totalizer and batch counter
Large 14 mm display LED, 6-digits, programmable
NE218
Features
–– Preset counter with two presets
–– Display 6-digits
–– Totalizer, hour counter
–– Operating mode, start count, scaling factor
programmable
–– Connection: Incremental encoder or digital sensors
–– Preset mode programmable
–– Interface RS422/RS485
NE218 - LED Preset counter
Technical data - electrical ratings
Technical data - electrical ratings
Voltage supply
115/230 VAC ±10 % (50/60 Hz)
24/48 VAC ±10 % (50/60 Hz)
24 VDC ±10 %
Programmable
parameters
Power consumption
5 VA, 4 W
Sensor supply
12...26 VDC / max. 85 mA
Operating modes
Sensor logic
Scaling factor
Count mode
Control inputs
Display
LED, 7-segment display
Approvals
UL/cUL, CE conform
Number of digits
6-digits
Digit height
14 mm
Function
Preset counter
Main counter with 2 presets
Totalizer
Hour counter
Count modes
Adding or subtracting
A-B (difference counting)
A+B total (parallel counting)
Up/Down
A 90° B phase evaluation
Counting frequency
3 Hz, 25 Hz, 10 kHz
programmable
Operating modes
Step preset, Main preset,
Parallel alignment, Trailing
preset
Data memory
>10 years in EEPROM
Reset
Button, electric or automatic
Outputs relay
Normally open or closed,
programmable
Output holding time
0.01...99.99 s
Interfaces
RS422, RS485
Standard
DIN EN 61010‑1
Protection class II
Overvoltage category II
Pollution degree 2
Emitted interference
DIN EN 61000-6-3
Interference immunity
DIN EN 61000-6-2
1
0...+50 °C
Storing temperature
-20...+70 °C
Relative humidity
80 % non-condensing
E-connection
Plug-in screw terminals
Core cross-section
1.5 mm²
Protection DIN EN 60529
IP 65 face with seal
Operation / keypad
Membrane with softkeys
Housing type
Built-in housing
Dimensions W x H x L
96 x 48 x 114.7 mm
Installation depth
115 mm
Mounting
Clip frame
Cutout dimensions
92 x 45 mm (+0.6)
Materials
Housing: Makrolon 6485 (PC)
Keypad: Polyester
Weight approx.
350 g (AC), 250 g (DC)
www.baumerivo.com
Subject to modification in technic and design. Errors and omissions excepted.
0.0001...9999.99
Operating temperature
30/10/2008
Scaling factor
Technical data - mechanical design
Preset counters electronic
2 presets, totalizer and batch counter
Large 14 mm display LED, 6-digits, programmable
NE218
Part number
Block circuit diagram
NE218.
1
AX01
Voltage
supply
Voltage supply
1 24 / 48 VAC
2 115 / 230 VAC
3 24 VDC
-
1
+
2
7
Sensor
supply
+
8
Totalizer
Outputs
1 Relay outputs
Interface
0 Without interface
1 RS422 / RS485
Output
Signal input
A
9
B
10
Control input
1
Reset
11
Stop/Hold 2
12
RS485
T,R+
RS422
TxD+ 22
T,R-
TxD- 23
A 90° B
3
Main counter
with 2 presets
start count
scaling factor
4
5
P1
P2
6
Operating
time meter
Interface
RS485/RS422
RxD+ 24
RxD- 25
Connection diagram
7
+24V 0V
6
5
P2
4
3
2
P1
max. 250 V
terminal - terminal /
- terminal
1
Comparator inputs
Input circuit
Inputs
PNP- / NPN- / AC-logic
Input level
Programmable
Input level Low
0...2 VDC
Input level High
3...40 VDC
Input resistance
3 kΩ
Relay outputs
Output circuit
Switching voltage max.
250 VAC / 110 VDC
Switching current max.
1A
Switching capacity max.
150 VA / 30 W
Relay responding time
5 ms
96
Subject to modification in technic and design. Errors and omissions excepted.
Dimensions
7
48
114.7
109
10.7
1-10
2
www.baumerivo.com
30/10/2008
8
Sensor
supply
9
Track A
Track B
10
Signal
input
11
Control input 1
TxD+
T,R+
T,R-
RS485
Control input 2
TxD-
RxD-
RxD+
RS422
12
Supply voltage
Trigger level
25 24 23 22