LINKCOM LAL2014-50

LAL2014-50
Broadband Access Transformer
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and
250V working voltage
RoHS Compliant
Excellent THD performance
Operating Temperature -40°C to 85°C
Electrical Specifications @25℃
OCL:
PIN 16-9= 2.0mH ±6% @ 10KHz/0.1V/Ser.
PIN 1-4= 10uH ±5.0 @ 100KHz/0.1V
Leakage
Inductance:
PIN 5-8= 0.4uH ± 0.5
PIN 1-16= 9.0 pF ± 5.0
IInterwinding
Capacitance
@ 100KHz/0.1V
@ 100KHz/0.1V
PIN 5-16= 13 pF ± 5.0
PIN 1-8= 17 pF ± 5.0
PIN 16-9 to PIN 1-4= -82dB Max. @ 30KHz/3.162V
T.H.D
PIN 16-9 to PIN 5-8= -82dB Max. @ 30KHz/3.162V
PIN 1-4 = 2.3 ohm Max.
D.C.R:
PIN 5-8 = 625 mohm Max.
Hi-POT :
PIN 16-9 = 1.15 ohm Max.
PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA
PIN16-9 : PIN 1-4 = 1±2% :1
Turn Ratio:
PIN16-9 : PIN 5-8 = 4.29±2% :1
Dimensions (Units: mm)
3.40
3.40
X DATE CODE G
F
19.0
LinkCom
Rx
14.0
14.4±0.5
LAL****
1.70
1.00
SUGGESTED PAD LAYOUT
C
13.5±0.5
A
12.6±0.5
+1.00
-0.50
12.5
8
Mark
2. X----PRODUCT LINE
0.3
+0.15
-0.10
3. DATE CODE----YYWW
Form Ver. A
D
13.0±0.5
15.5±0.5
E 17.0 +1.0
-0.5
11
14
7
6
1.LAL****----LAL2014
B
16
3
2
4
5
Tx
1.7±0.3
PIN1
PRI
1
1.70
0.7TYP.
0.5TYP.
13.5±0.5
G
SEC
5.10
5.1±0.3
3.4±0.3
Schematic
4. G----RoHS
9
LINE