LAL0665-53 Broadband Access Transformer Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and 250V working voltage RoHS Compliant Excellent THD performance Operating Temperature -40°C to 85°C Electrical Specifications @25℃ OCL: PIN 9-16= 100uH ±10% @ 10KHz/0.1V/Ser. PIN 1-4= 4.2uH ±1.5 Leakage Inductance: @ 100KHz/0.1V PIN 5-8= 120 nH Ref. PIN 9-16= 4.3uH ±1.5 PIN1-16= 9.0 pF±2 pF . @ 100KHz/0.1V Interwining Capacitance: PIN5-16= 8.3 pF±2.7 pF PIN 1-8= 12 pF±4.0 pF PIN 1-4 to PIN 9-16 = -80dB Max. @ 30KHz/3.162V T.H.D PIN 5-8 to PIN 9-16 = -75dB Max. @ 30KHz/3.162V PIN 1-3 = 210 mohm ±15% PIN 2-4 = 210 mohm ±15% PIN 5-8 = 57 mohm ±15% PIN 6-8 = 57 mohm ±15% PIN 16-11 = 200 mohm 57 ±15% PIN 14-9 = 200 mohm 57 ±15% D.C.R: Hi-POT : PRI. – SEC. =1875VAC/60Hz2Seconds/1mA Turn Ratio: PIN1-4 : PIN 16-9 = 1±3% :1 Dimensions Units: mm Schematic 3.40 3.40 X DATE CODE G F 1.7±0.3 PIN1 1.70 1.00 19.0 Rx 14.0 14.4±0.5 LAL**** LinkCom PRI 1 1.70 0.7TYP. 0.5TYP. 13.5±0.5 G SEC 5.10 5.1±0.3 3.4±0.3 PIN5-8 : PIN 16-9= 4.25±3% :1 4 5 Tx 8 C 13.5±0.5 +1.00 -0.50 12.5 Mark 1.LAL****----LAL0660 B 2. X----PRODUCT LINE 0.3 +0.15 -0.10 3. DATE CODE----YYWW Form Ver. A D 13.0±0.5 15.5±0.5 E 17.0 +1.0 -0.5 11 14 7 6 SUGGESTED PAD LAYOUT A 12.6±0.5 16 3 2 4. G----RoHS 9 LINE