LINKCOM LAL1243-50

LAL1243-50
Broadband Access Transformer
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and
250V working voltage
RoHS Compliant
Excellent THD performance
Operating Temperature -40°C to 85°C
Electrical Specifications @25℃
OCL:
PIN 1-4= 82uH ±10% @ 10KHz/0.1V/Ser.
Leakage
Inductance:
PIN 1-4= 0.35 uH Max. @ 100KHz/0.1V
IInterwinding
Capacitance
PIN 1-8= 30 pF Max. @ 100KHz/0.1V
T.H.D
PIN 1-4 to PIN 8-5= -80dB Max. @ 138KHz/2V
LCL
-38dBMax. @ 17MHz/0.1V
PIN 1-4= 2.0 ohm Max.
D.C.R:
PIN 8-5 = 1.0 ohm Max.
Hi-POT :
PRI. – SEC. =1500VAC/60Hz/2Seconds/1mA
Turn Ratio:
PIN1-4 : PIN 8-5 = 1.33±2% :1
Dimensions (Units: mm)
Schematic
X DATE CODE G
8.0Max
A
4.1
8.8
LAL****
LinkCom
8.5Max
1.90
B
PIN1
0.80
10.0Max
SUGGESTED PAD LAYOUT
Mark
1.LAL****----LAL1243
C
2. X----PRODUCT LINE
3. DATE CODE----YYWW
1.9±0.5 E
SQ0.4±0.2 F
Form Ver. A
5.1Ref
7.8±0.5
D
4. G----RoHS