SPECIFICATION
ID-50A
MODEL
OUTPUT
INPUT
ID-50D
CH2
CH1
CH2
CH1
CH2
CH1
DC VOLTAGE
5V
5V
13.5V
13.5V
27V
27V
5V
13.5V
RATED CURRENT
6A
2A
1.8A
1.8A
0.9A
0.9A
5A
1.7A
CURRENT RANGE
0.5 ~ 6A
0 ~ 2A
0.3 ~ 2A
0 ~ 2A
0.18 ~ 1A
0 ~ 1A
1 ~ 5A
0 ~ 2A
RATED POWER
40W
RIPPLE & NOISE (max.) Note.2 50mVp-p
48.6W
100mVp-p
VOLTAGE ADJ. RANGE
CH1,2 : 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 1.0%
2.0%
48.6W
100mVp-p
150mVp-p
CH1,2 : 12 ~ 15V
1.0%
2.0%
100mVp-p
CH2
48W
150mVp-p
CH1,2 : 24 ~ 30V
1.0%
2.0%
50mVp-p
150mVp-p
CH1 : 4.75 ~ 5.5V
1.0%
2.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.3%
0.5%
0.5%
0.5%
LOAD REGULATION
0.5%
1.0%
0.5%
1.0%
0.3%
1.0%
0.5%
1.0%
SETUP, RISE TIME
1600ms, 50ms at full load
HOLD TIME (Typ.)
VOLTAGE RANGE
100ms at full load
85 ~ 264VAC
120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
66%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1A/115VAC
0.6A/230VAC
COLD START 22A/115VAC
45A/230VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
MTBF
DIMENSION
PACKING
NOTE
ID-50C
CH1
LEAKAGE CURRENT
OTHERS
ID-50B
OUTPUT
72%
70%
68%
<3.5mA / 240VAC
105 ~ 150%/115VAC rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
13.5V:17 ~ 21V
27V:32 ~ 40V
5V: 6.4 ~ 7.5V
5V:6.4 ~ 7.5V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )on +5V output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Design refer to UL1012
I/P-O/P:1.5KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Design refer to FCC Part15
312.2K hrs min. MIL-HDBK-217F (25
159*97*38mm (L*W*H)
0.54Kg; 24pcs/13.8Kg/0.75CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
File Name:ID-50-SPEC 2007-08-30
ID-50
50W Isolated Dual Output Switching Power Supply
Mechanical Specification
Case No. 901
4.5
series
Unit:mm
3.5
11
7
152.5
1
65
8.25
2
3
5
7
6
2 -M
97
84.5
4
3
7
+V1 ADJ
+V2 ADJ
3 .5
78
24
159
150
22
M3
38
3.5
18
3 .5
3-
28.5
18.5
9
6.5
117
Terminal Pin No. Assignment
Pin No.
1
2
3
4
Assignment
AC/L
AC/N
FG
DC OUTPUT G2
Pin No.
5
6
7
Assignment
DC OUTPUT +V2
DC OUTPUT G1
DC OUTPUT +V1
Derating Curve
Static Characteristics(B)
Ta=25
OUTPUT VOLTAGE (V)
100
80
LOAD (%)
60
40
20
-10
-10
0
0
10
20
30
40
50
45
AMBIENT TEMPERATURE ( )
60 (VERTICAL)
55 (HORIZONTAL)
+13.5V
300
12
250
10
200
8
150
6
100
4
50
+13.5V
2
25
60
80
100
120
140
160
180
200
220
240
OUTPUT RIPPLE (mVp-p)
14
260
INPUT VOLTAGE (V) 60Hz
File Name:ID-50-SPEC 2007-08-30