ID-60B 60W Isolated Dual Output Switching Power Supply Features : Isolated output & GND for CH1,CH2 Universal AC input/Full range Protections:Short circuit/Over load/Over voltage Coolig by free air convection 100% full load burn-in test Fixed switching frequency at 54KHz 2 years warranty SPECIFICATION MODEL OUTPUT INPUT ID-60B OUTPUT NUMBER CH1 CH2 DC VOLTAGE 5V 24V RATED CURRENT 3A 1.8A CURRENT RANGE 0.3 ~ 6A 0.2 ~ 2.2A RATED POWER 58W RIPPLE & NOISE (max.) Note.2 100mVp-p 240mVp-p VOLTAGE ADJ. RANGE CH1 : 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION 0.5% LOAD REGULATION 0.5% 8.0% 1.0% 5.0% SETUP, RISE TIME 300ms, 50ms/230VAC HOLD TIME (Typ.) VOLTAGE RANGE 90ms/230VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 76% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2A/115VAC 1A/230VAC COLD START 25A/115VAC LEAKAGE CURRENT <1mA / 240VAC 85 ~ 264VAC 800ms, 50ms/115VAC at full load 10ms/115VAC at full load 120 ~ 370VDC 45A/230VAC 105% ~ 150% rated output power OVER LOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION EMC (Note 4) HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (-10 80% load, 60 60% load) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A 320.9K hrs min. MIL-HDBK-217F (25 159*97*38mm (L*W*H) 0.55Kg; 24pcs/13.9Kg/0.75CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:ID-60B-SPEC 2005-09-13 ID-60B 60W Isolated Dual Output Switching Power Supply Mechanical Specification Case No. 901 Unit:mm 3.5 7 152.5 1 65 2 9.5 3 8.2 5 2 -M 6 97 84.5 4 3 7 3 .5 4.5 78 24 159 150 22 38 3.5 M3 28.5 3 .5 3- 18 18.5 9 9 6.5 117 Terminal Pin. No Assignment Pin No. 1 2 3 4 Assignment AC/L AC/N FG DC OUTPUT +V Pin No. 5 6 7 Assignment DC OUTPUT G2 DC OUTPUT +5V DC OUTPUT G1 Output Derating Static Characteristics Ta=25 OUTPUT VOLTAGE (V) +5V 80 LOAD (%) 60 40 20 0 0 10 20 30 40 50 45 AMBIENT TEMPERATURE ( ) 60 55 (VERTICAL) (HORIZONTAL) 250 24 5.0 +24V 23 4.8 200 22 4.6 150 21 4.4 100 20 4.2 +24V 50 19 4.0 +5V 25 60 80 100 120 140 160 180 200 220 240 OUTPUT RIPPLE (mVp-p) 100 -10 -10 300 25 5.2 260 INPUT VOLTAGE (V) 60Hz File Name:ID-60B-SPEC 2005-09-13