MEANWELL ID-60B

ID-60B
60W Isolated Dual Output Switching Power Supply
Features :
Isolated output & GND for CH1,CH2
Universal AC input/Full range
Protections:Short circuit/Over load/Over voltage
Coolig by free air convection
100% full load burn-in test
Fixed switching frequency at 54KHz
2 years warranty
SPECIFICATION
MODEL
OUTPUT
INPUT
ID-60B
OUTPUT NUMBER
CH1
CH2
DC VOLTAGE
5V
24V
RATED CURRENT
3A
1.8A
CURRENT RANGE
0.3 ~ 6A
0.2 ~ 2.2A
RATED POWER
58W
RIPPLE & NOISE (max.) Note.2 100mVp-p
240mVp-p
VOLTAGE ADJ. RANGE
CH1 : 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
LOAD REGULATION
0.5%
8.0%
1.0%
5.0%
SETUP, RISE TIME
300ms, 50ms/230VAC
HOLD TIME (Typ.)
VOLTAGE RANGE
90ms/230VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
76%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
2A/115VAC
1A/230VAC
COLD START 25A/115VAC
LEAKAGE CURRENT
<1mA / 240VAC
85 ~ 264VAC
800ms, 50ms/115VAC at full load
10ms/115VAC at full load
120 ~ 370VDC
45A/230VAC
105% ~ 150% rated output power
OVER LOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
EMC
(Note 4)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60 (-10 80% load, 60 60% load)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )on +5V output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
320.9K hrs min. MIL-HDBK-217F (25
159*97*38mm (L*W*H)
0.55Kg; 24pcs/13.9Kg/0.75CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:ID-60B-SPEC 2005-09-13
ID-60B
60W Isolated Dual Output Switching Power Supply
Mechanical Specification
Case No. 901
Unit:mm
3.5
7
152.5
1
65
2
9.5
3
8.2
5
2 -M
6
97
84.5
4
3
7
3 .5
4.5
78
24
159
150
22
38
3.5
M3
28.5
3 .5
3-
18
18.5
9
9
6.5
117
Terminal Pin. No Assignment
Pin No.
1
2
3
4
Assignment
AC/L
AC/N
FG
DC OUTPUT +V
Pin No.
5
6
7
Assignment
DC OUTPUT G2
DC OUTPUT +5V
DC OUTPUT G1
Output Derating
Static Characteristics
Ta=25
OUTPUT VOLTAGE (V)
+5V
80
LOAD (%)
60
40
20
0
0
10
20
30
40
50
45
AMBIENT TEMPERATURE ( )
60
55
(VERTICAL)
(HORIZONTAL)
250
24 5.0
+24V
23 4.8
200
22 4.6
150
21 4.4
100
20 4.2
+24V
50
19 4.0
+5V
25
60
80
100
120
140
160
180
200
220
240
OUTPUT RIPPLE (mVp-p)
100
-10
-10
300
25 5.2
260
INPUT VOLTAGE (V) 60Hz
File Name:ID-60B-SPEC 2005-09-13