T- 6 0 60W Triple Output Switching Power Supply series Features : Universal AC input / Full range Protections:Short circuit/Over load/Over voltage Cooling by free air convection LED indicator for power on Fixed switching frequency at 50KHz 2 years warranty SPECIFICATION MODEL OUTPUT INPUT T-60A T-60B T-60C OUTPUT NUMBER CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 DC VOLTAGE 5V 12V -5V 5V 12V -12V 5V 15V -15V RATED CURRENT 5A 2.5A 0.5A 5A 2.5A 0.5A 5A 2A 0.5A CURRENT RANGE 0.5 ~ 7A 0.2 ~ 3.5A 0 ~ 1A 0.5 ~ 7A 0.2 ~ 3.5A 0 ~ 1A 0.5 ~ 7A 0.2 ~ 3A 0 ~ 1A RATED POWER 57.5W 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 61W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p VOLTAGE ADJ. RANGE CH1 : 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 6.0% 62.5W CH1 : 4.75 ~ 5.5V 2.0% 6.0% 6.0% 6.0% 100mVp-p CH1 : 4.75 ~ 5.5V 2.0% 6.0% 6.0% LINE REGULATION 0.5% 1.0% 0.5% 0.5% 1.0% 0.5% 0.5% 1.0% 0.5% LOAD REGULATION 1.0% 4.0% 1.0% 1.0% 4.0% 1.0% 1.0% 4.0% 1.0% SETUP, RISE TIME 300ms, 50ms/230VAC HOLD TIME (Typ.) 80ms/230VAC VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY(Typ.) 72% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2A/115VAC 1A/230VAC COLD START 20A/115VAC LEAKAGE CURRENT <3.5mA / 240VAC OVER LOAD 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 800ms, 50ms/115VAC at full load 10ms/115VAC at full load 120 ~ 370VDC 72% 72% 40A/230VAC 5V: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on +5V output 10~500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1012, UL60950, TUV EN60950 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC (Note 4) HARMONIC CURRENT Compliance to EN61000-3-2,-3 OTHERS EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A MTBF 281.1K hrs min. MIL-HDBK-217F (25 159*97*38mm (L*W*H) 0.55Kg; 24pcs/14.1Kg/0.75CUFT DIMENSION PACKING NOTE ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:T-60-SPEC 2005-09-13 T- 6 0 60W Triple Output Switching Power Supply Mechanical Specification Case No. 901 series Unit:mm 3.5 7 152.5 1 3 84.5 4 8.2 5 6 2-M 97 65 9.5 2 3 7 3.5 4.5 78 24 159 150 22 3.5 38 3 28.5 3.5 3-M 18 18.5 9 9 6.5 117 Terminal Pin. No Assignment Assignment AC/L AC/N FG Pin No. 1 2 3 Pin No. 4 5 6 Assignment DC OUTPUT -V DC OUTPUT +V2 DC OUTPUT COM Pin No. 7 Assignment DC OUTPUT +V1 Output Derating Static Characteristics (B) Ta=25 80 LOAD (%) 60 40 20 5.2 12 5.0 +12V +5V 300 250 -12V 11 4.8 200 10 4.6 150 9 4.4 100 8 4.2 7 4.0 +12V +5V 50 25 OUTPUT RIPPLE (mVp-p) OUTPUT VOLTAGE (V) 100 13 -12V -10 -10 0 0 10 20 30 40 50 45 AMBIENT TEMPERATURE ( ) 60 55 (VERTICAL) (HORIZONTAL) 60 80 100 120 140 160 180 200 220 240 260 INPUT VOLTAGE (V) 60Hz File Name:T-60-SPEC 2005-09-13