MEANWELL IT-60F

I T- 6 0
60W Isolated Triple Output Switching Power Supply
series
Features :
Isolated output & GND for CH1,CH2,CH3
Universal AC input/Full range
Protections:Short circuit/Over load/Over voltage
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 67KHz
2 years warranty
SPECIFICATION
MODEL
OUTPUT
IT-60D
IT-60F
OUTPUT
CH1
CH2
CH3
CH1
CH2
DC VOLTAGE
5V
12V
24V
5V
15V
24V
RATED CURRENT
3A
0.8A
1.4A
3A
0.8A
1.3A
CURRENT RANGE
0.5 ~ 3A
0.1 ~ 1A
0.2 ~ 2A
0.5 ~ 3A
0.1 ~ 1A
0.2 ~ 2A
RATED POWER
58.2W
150mVp-p
240mVp-p
PEAK LOAD (3sec.)
58.2W
Note.4 70W
RIPPLE & NOISE (max.) Note.2 80mVp-p
120mVp-p
240mVp-p
VOLTAGE ADJ. RANGE
CH1 : 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 3.0%
INPUT
CH3
80mVp-p
CH1 : 4.75 ~ 5.5V
3.0%
8.0%
8.0%
8.0%
8.0%
LINE REGULATION
1.0%
2.0%
2.0%
1.0%
2.0%
2.0%
LOAD REGULATION
2.0%
5.0%
5.0%
2.0%
5.0%
5.0%
SETUP, RISE TIME
300ms, 20ms/230VAC
HOLD TIME (Typ.)
80ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
76%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.8A/115VAC
0.9A/230VAC
COLD START 20A/115VAC
40A/230VAC
LEAKAGE CURRENT
800ms, 20ms/115VAC at full load
18ms/115VAC at full load
127 ~ 370VDC
<1mA / 240VAC
72 ~ 90W rated output power
OVER LOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5V: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )on +5V output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY & ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
EMC
(Note 5)
OTHERS
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, Light industry level, criteria A
314.3K hrs min. MIL-HDBK-217F (25 )
159*97*38mm (L*W*H)
0.51Kg; 24pcs/13.2Kg/0.75CUFT
DIMENSION
PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 5% Duty cycle maximum within every 1min. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:IT-60-SPEC 2006-08-01
I T- 6 0
60W Isolated Triple Output Switching Power Supply
Mechanical Specification
Case No. 901
series
Unit:mm
3.5
7
152.5
1
2
65
7.62
3
4
6
7
2-M
97
84.5
5
3
7
8
9
10
3.5
4.5
78
24
159
150
22
3.5
38
3
28.5
3.5
3-M
18
18.5
9
9
6.5
117
Terminal Pin. No Assignment
Pin No.
1
2
3
4
Pin No.
5
6
7
8
Assignment
AC/L
AC/N
FG
NC
Assignment
DC OUTPUT G2
DC OUTPUT +V2
DC OUTPUT G3
DC OUTPUT +V3
Pin No.
9
10
Assignment
DC OUTPUT G1
DC OUTPUT +5V
Output Derating
Static Characteristics
Ta=25
100
OUTPUT VOLTAGE (V)
60
LOAD (%)
300
+5V
80
40
20
-10
-10
25 5.2
0
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
(HORIZONTAL)
12,15
24 5.0
250
+12V,+15V,+24V
11,14
23 4.8
200
10,13
22 4.6
150
9,12
21 4.4
100
8,11
20 4.2
+12V,+15V,+24V
50
7,10
19 4.0
+5V
25
60
80
100
120
140
160
180
200
220
240
OUTPUT RIPPLE (mVp-p)
13,16
260
INPUT VOLTAGE (V) 60Hz
File Name:IT-60-SPEC 2006-08-01