I T- 6 0 60W Isolated Triple Output Switching Power Supply series Features : Isolated output & GND for CH1,CH2,CH3 Universal AC input/Full range Protections:Short circuit/Over load/Over voltage LED indicator for power on 100% full load burn-in test Fixed switching frequency at 67KHz 2 years warranty SPECIFICATION MODEL OUTPUT IT-60D IT-60F OUTPUT CH1 CH2 CH3 CH1 CH2 DC VOLTAGE 5V 12V 24V 5V 15V 24V RATED CURRENT 3A 0.8A 1.4A 3A 0.8A 1.3A CURRENT RANGE 0.5 ~ 3A 0.1 ~ 1A 0.2 ~ 2A 0.5 ~ 3A 0.1 ~ 1A 0.2 ~ 2A RATED POWER 58.2W 150mVp-p 240mVp-p PEAK LOAD (3sec.) 58.2W Note.4 70W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 240mVp-p VOLTAGE ADJ. RANGE CH1 : 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 3.0% INPUT CH3 80mVp-p CH1 : 4.75 ~ 5.5V 3.0% 8.0% 8.0% 8.0% 8.0% LINE REGULATION 1.0% 2.0% 2.0% 1.0% 2.0% 2.0% LOAD REGULATION 2.0% 5.0% 5.0% 2.0% 5.0% 5.0% SETUP, RISE TIME 300ms, 20ms/230VAC HOLD TIME (Typ.) 80ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY(Typ.) 76% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.8A/115VAC 0.9A/230VAC COLD START 20A/115VAC 40A/230VAC LEAKAGE CURRENT 800ms, 20ms/115VAC at full load 18ms/115VAC at full load 127 ~ 370VDC <1mA / 240VAC 72 ~ 90W rated output power OVER LOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE Protection type : Hiccup mode, recovers automatically after fault condition is removed 5V: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC (Note 5) OTHERS HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, Light industry level, criteria A 314.3K hrs min. MIL-HDBK-217F (25 ) 159*97*38mm (L*W*H) 0.51Kg; 24pcs/13.2Kg/0.75CUFT DIMENSION PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 5% Duty cycle maximum within every 1min. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:IT-60-SPEC 2006-08-01 I T- 6 0 60W Isolated Triple Output Switching Power Supply Mechanical Specification Case No. 901 series Unit:mm 3.5 7 152.5 1 2 65 7.62 3 4 6 7 2-M 97 84.5 5 3 7 8 9 10 3.5 4.5 78 24 159 150 22 3.5 38 3 28.5 3.5 3-M 18 18.5 9 9 6.5 117 Terminal Pin. No Assignment Pin No. 1 2 3 4 Pin No. 5 6 7 8 Assignment AC/L AC/N FG NC Assignment DC OUTPUT G2 DC OUTPUT +V2 DC OUTPUT G3 DC OUTPUT +V3 Pin No. 9 10 Assignment DC OUTPUT G1 DC OUTPUT +5V Output Derating Static Characteristics Ta=25 100 OUTPUT VOLTAGE (V) 60 LOAD (%) 300 +5V 80 40 20 -10 -10 25 5.2 0 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 (HORIZONTAL) 12,15 24 5.0 250 +12V,+15V,+24V 11,14 23 4.8 200 10,13 22 4.6 150 9,12 21 4.4 100 8,11 20 4.2 +12V,+15V,+24V 50 7,10 19 4.0 +5V 25 60 80 100 120 140 160 180 200 220 240 OUTPUT RIPPLE (mVp-p) 13,16 260 INPUT VOLTAGE (V) 60Hz File Name:IT-60-SPEC 2006-08-01