MEANWELL PPS-125-3.3

PPS-125
125W Single Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage
PWM control and regulated
High power density 6.117W/inch3
Built-in remote sense function
LED indicator for power on
100% full load burn-in test
125W with 18CFM FAN
5"x3" compact size
3 years warranty
SPECIFICATION
MODEL
OUTPUT
PPS-125-3.3
PPS-125-5
PPS-125-12
PPS-125-13.5 PPS-125-15
PPS-125-24
PPS-125-27
DC VOLTAGE
3.3V
5V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
20A
20A
8.5A
7.5A
6.7A
4.2A
3.8A
2.1A
CURRENT RANGE (convection) 0 ~ 20A
0 ~ 20A
0 ~ 8.5A
0 ~ 7.5A
0 ~ 6.7A
0 ~ 4.2A
0 ~ 3.8A
0 ~ 2.1A
CURRENT RANGE (18CFM FAN) 0 ~ 25A
0 ~ 25A
0 ~ 10.5A
0 ~ 9.3A
0 ~ 8.4A
0 ~ 5.2A
0 ~ 4.6A
0 ~ 2.6A
RATED POWER (convection) 66W
100W
102W
101.25W
100.5W
100.8W
102.6W
100.8W
RATED POWER (18CFM FAN) 82.5W
125W
126W
125.55W
126W
124.8W
124.2W
124.8W
RIPPLE & NOISE (max.) Note.2 100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
150mVp-p
150mVp-p
250mVp-p
VOLTAGE ADJ. RANGE
4.75 ~ 5.25V
2.0%
11.40 ~ 12.60V 12.82 ~ 14.17V 14.25 ~ 15.75V 22.80 ~ 25.20V 25.65 ~ 28.35V 45.60 ~ 50.40V
2.0%
2.0%
2.0%
1.0%
1.0%
1.0%
VOLTAGE TOLERANCE Note.3
INPUT
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
SETUP, RISE TIME
1000ms, 30ms/230VAC
HOLD UP TIME (Typ.)
24ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47~63Hz
POWER FACTOR (Typ.)
PF>0.93/230VAC
EFFICIENCY (Typ.)
70%
79%
1.2A
1.7A
115VAC
230VAC
INRUSH CURRENT (Typ.)
80%
80%
80%
83%
83%
84%
0.6A
0.75A
COLD START 24A/230VAC
OVERLOAD
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
NOTE
PF>0.98/115VAC at full load
<2mA / 240VAC
WORKING TEMP.
WORKING HUMIDITY
OTHERS
24ms/115VAC at full load
127 ~ 370VDC
130 ~ 160% rated output power
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
(Note 4)
2000ms, 30ms/115VAC at full load
LEAKAGE CURRENT
PROTECTION
EMC
3.13 ~ 3.46V
2.0%
LINE REGULATION
AC CURRENT
(Typ.)
SAFETY &
PPS-125-48
3.63 ~ 4.45V
5.5 ~ 6.75V
13.8 ~ 16.2V
15.5 ~ 20.25V 17.25 ~ 20.25V 27.6 ~ 32.4V
31.05 ~ 36.45V 57.6 ~ 67.2V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
SAFETY STANDARDS
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
EMS IMMUNITY
MTBF
111.7Khrs min. MIL-HDBK-217F (25 )
DIMENSION
PACKING
127*76.2*34.6mm (L*W*H)
0.37Kg; 36pcs/14.3Kg/0.79CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Heat Sink HS1,HS2 & HS3 can not be shorted.
File Name:PPS-125-SPEC 2008-10-22
PPS-125
125W Single Output with PFC Function
Mechanical Specification
series
Unit:mm
127
115.6
6.4
5
HS3
SVR1
FS1
T2A 250VAC
64.8
76.2
HS1
1
2
3
CN1
LED1
1 CN3
2
1
2
3
4
5
6
7
8
HS2
CN5
Pin No.
1
2
3
Assignment
AC/L
No Pin
AC/N
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
DC Output Connector (CN5) : JST B8P-VH or equivalent
43.
5
Air flow
direction
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No.
1~4
5~8
Assignment
-V
+V
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
Remote Sense(CN3) : Molex 5045-02 or equivalent
34.6
Pin No.
1
2
Assignment
RS+
RS-
Mating Housing
Terminal
Molex 5051
or equivalent
Molex 4809
or equivalent
3max.
HS1, HS2 & HS3 can not be shorted
Block Diagram
fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
PFC
CIRCUIT
RECTIFIERS
&
FILTER
POWER
SWITCHING
FG
O.L.P.
Derating Curve
O.V.P.
Output Derating VS Input Voltage
100
Forced air 18CFM
90
100
Free air Convection
80
70
70
50
60
LOAD(%)
LOAD (%)
FEEDBACK
DETECTION
CIRCUIT
PWM & PFC
CONTROL
125
20
-20
+V
-V
0
10
20 25 30
40
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
50
40
90
100
115
135
155
264
INPUT VOLTAGE (V) 60Hz
File Name:PPS-125-SPEC 2008-10-22