F4000RW Datasheet - Micropower Direct

F4000RW Series
Wide 2:1 Input, 40W
Compact, Single Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 40W Output Power
• 2:1 Input Voltage Range
• 1,600 VDC Isolation
• High Efficiency
• Compact 2 x 1.6 In. Case
• Industry Standard Pin-Out
• Remote ON/OFF
• Low Output Voltages
Input
Parameter
Input Voltage Range
Input Filter
Conditions
Min.
36.0
␲ (Pi) Filter
Typ.
48.0
Max.
75.0
Units
VDC
Conditions
Min.
Typ.
±2.0
±0.5
±1.0
Max.
Units
%
%
%
mV P - P
%
mV P - P
%
%
%
%/°C
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple, See Note 1
Noise, See Note 1
Output Power Protection, See Note 2
Over Voltage Protection, See Note 3
Temperature Coefficient
Output Short Circuit
For Vin Min to Max
Iout = 10% to 100%
1.8. 2.5, 3.3 VDC Output
All Other Outputs
1.8. 2.5, 3.3 VDC Output
All Other Outputs
50
±1.0
100
±1.0
120
112
±0.01
Continuous (Autorecovery)
165
±0.02
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Remote On/Off, See Note 4
Parameter
Supply On
Supply Off
Input Current (On)
Input Current (Off)
Control Common
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,600
1,000
Typ.
Max.
1,000
400
Units
VDC
M⍀
pF
kHz
Conditions
Open Circuit Or
Min.
5.0
-1.0
Typ.
Max.
Units
15.0
VDC
+1.0
VDC
-1
mA
1
mA
Referenced to Negative Input (pin 2)
Conditions
Min.
-25
Typ.
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Ambient
Case
-55
See Derating Curve
RH, Non-condensing
Max.
+70
+100
+105
Units
°C
°C
°C
95
%
2.0 x 1.6 x 0.47 Inches (50.8 x 40.6 x 11.9 mm)
Nickel Coated Copper with Non-Conductive Base
2.11 Oz (58g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
550
Typ.
Max.
Units
kHours
Min.
-0.7
Typ.
Max.
100.0
260
Units
VDC
°C
Absolute Maximum Ratings
Parameter
Input Voltage Surge (0.1 Sec)
Lead Temperature
Conditions
1.5 mm From Case For 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
F4021RW
F4022RW
F4023RW
F4024RW
F4025RW
F4026RW
F4027RW
Voltage (VDC)
Nominal
Range
48
48
48
48
48
48
48
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
Output
Current (mA)
Voltage
Current
Current
Full-Load No-Load
(VDC)
(mA, Max)
(mA, Min)
384
508
655
969
1,004
1,004
992
110
110
110
110
30
30
30
1.8
2.5
3.3
5.0
12.0
15.0
24.0
Notes:
1. When measuring output ripple, it is recommended that an external 1.0 µF ceramic in parallel with
a 10 µF capacitor be placed from the +Vout pin to the -Vout pin.
2. The unit will recover automatically when the fault condition is removed.
3. Over voltage protection is provided by a zener diode clamp.
4. If the on/off pin (Pin 4) is left open, the unit operates.
5. No load operation will not damage these units, but they may not meet all spec’s.
6. It is recommended that a fuse be used on the input of a power supply for protection. See the table
above for the correct rating.
8,000
8,000
8,000
8,000
3,333
2,666
1,666
Maximum
Fuse Rating
Efficiency
Output
Slow-Blow
Power
(%, Typ)
(mA)
(W)
800.0
800.0
800.0
800.0
333.0
266.0
166.0
14.4
20.0
26.4
40.0
40.0
40.0
40.0
78
82
84
86
83
83
84
1,000
1,000
1,500
2,000
2,000
2,000
2,000
Derating Curve
External Trim
A simple external circuit may be used
to adjust the converter output. The
adjustment range is ±10%.
To adjust the output DOWN, connect
a 5%, 3W resistor between the plus
output pin and the Vout trim pin. To
adjust the output UP, connect a 5%,
3W resistor between the minus output
pin and the Vout trim pin.
For UP/Down trimming capability,
connect a 10 kW potentiometer between the plus and minus outputs
with the wiper arm connected to the
Vout trim pin.
Pin Connections
Pin Function
1
+Vin
2
-Vin
4
ON/OFF
Mechanical Dimensions
Pin Function
6
+Vout
7
-Vout
8
Trim
Mechanical Notes:
MicroPower Direct
• All dimensions are typical
in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]