I2000RU Series Ultra-Miniature 20W Wide 4:1 Input Range DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: Input • 20W Output Power • 4:1 Input Range • Ultra- Miniature Case • Remote On/Off Control • 1,500 VDC Isolation • >346 kHour MTBF • Standard Pin-Out Parameter Input Voltage Range Start-Up Voltage Under Voltage Shutdown Input Filter Conditions Min. 24 VDC Input 9.0 48 VDC Input 18.0 24 VDC Input 48 VDC Input 24 VDC Input 48 VDC Input LC Filter Typ. 24.0 48.0 Conditions Typ. Max. 36.0 75.0 9.0 18.0 8.5 17.0 Units Max. ±1.0 ±2.0 ±0.2 ±0.5 ±0.5 ±0.2 ±1.0 Units % % VDC VDC VDC Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation, VIN = Min to Max Load Regulation, IOUT = 15% to 100% Ripple & Noise (20 MHz), See Note 1 Transient Recovery Time, See Note 2 Transient Response Deviation Output Power Protection Temperature Coefficient Output Short Circuit Min. Dual Output , Balanced Loads Single Output Dual Output Single Output (3.3V and 5V) Single Output (12V and 15V) Dual Output Single Output (3.3V and 5V) Single Output (12V and 15V) Dual Output 75 100 100 300 ±3.0 150 25% Load Step Change % % mV P - P ±0.02 µSec % % %/ºC Continuous (Autorecovery) General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Conditions 60 Seconds 500 VDC 100 kHz, 1V Min. 1,500 1,000 Typ. Max. Units VDC M pF kHz Max. +85 +105 +125 Units ºC ºC ºC 95 % 1,500 330 Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Derating Humidity Physical Case Size Case Material Weight Conditions Ambient Case Min. -40 Typ. +25 -50 Free Air Convection See Curve RH, Non-condensing 1.00 x 1.00 x 0.40 Inches (25.4 x 25.4 x 10.16 mm) Six-Sided Shielded Aluminum With Non-Conductive Base (UL94-V0) 0.52 Oz (15g) Reliability Specifications Parameter MTBF Conditions MIL HDBK 217F, 25ºC, Gnd Benign Min. 346 Typ. Max. Units kHours Conditions 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec Min. -0.7 -0.7 Typ. Max. 50.0 100.0 260 Units Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC ºC www.micropowerdirect.com Model Selection Guide Input Model Number I2001RU I2002RU I2003RU I2004RU I2005RU I2006RU I2011RU I2012RU I2013RU I2014RU I2015RU I2016RU Voltage (VDC) Nominal 24 24 24 24 24 24 48 48 48 48 48 48 Output Current (mA) Range Full-Load No-Load 9.0 - 36.0 1,390 80 9.0 - 36.0 1,852 90 9.0 - 36.0 1,877 40 9.0 - 36.0 1,882 40 9.0 - 36.0 1,877 40 9.0 - 36.0 1,882 40 18.0 - 75.0 695 40 18.0 - 75.0 926 45 18.0 - 75.0 938 25 18.0 - 75.0 930 25 18.0 - 75.0 938 25 18.0 - 75.0 941 25 Notes: 1. Output ripple is measured with a 1.0 µF ceramic and a 10 µF tantalum capcitor connected across the outputs. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Operation at no-load will not damage the unit, but they may not meet all specifications. Min Max 4. The On/Off Control input (Pin 3) is referenced to -Vin (Pin 2). If On 3.5 VDC 12 VDC it is not used, the control pin Off 0.0 VDC 1.2 VDC should be left open. If the pin 0.5 mA is shorted to -VIN, the unit will In. Current (on) In. Current (off) -0.5 mA turn off. 5. An external resistor may be used to adjust the converter output by ±10%. To adjust the output UP, connect a 5%, 3W resistor between the minus output pin and the Vout trim pin. To adjust the output DOWN, connect a 5%, 3W resistor between the plus output pin and the VOUT trim pin. For continuous UP/Down trimming capability, connect a 10 kW potentiometer between the plus and minus outputs with the wiper arm connected to the VOUT trim pin. The trim pin may be left floating if it is not used. Contact the factroy for more information. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Voltage Current Current (VDC) (mA, Max) (mA, Min) 3.3 5.0 12.0 15.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 ±12.0 ±15.0 4,500 4,000 1,670 1,340 ±835 ±670 4,500 4,000 1,670 1,340 ±835 ±670 0 0 0 0 ±60 ±50 0 0 0 0 ±60 ±50 Efficiency (%, Typ) Capacitive Fuse Rating Load Slow-Blow 87 89 89 89 89 89 88 89 89 89 89 89 (µF Max) (mA) 10,300 6,800 1,200 750 ±680 ±380 10,300 6,800 1,200 750 ±680 ±380 4,000 4,000 4,000 4,000 4,000 4,000 2,000 2,000 2,000 2,000 2,000 2,000 Derating Curve Mechanical Dimensions Pin Connections Pin 1 2 3 4 5 6 MicroPower Direct Single Dual +Vin +Vin -Vin -Vin Remote ON/OFF +Vout +Vout Trim Common -Vout -Vout Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]