MPD MPA300DX

MPA300D Series
Smallest 1U 300W
Dual Output
Power Factor Corrected Only
x 4 x 1.5
AC/DC Power Supplies 6Inches!!
Key Features:
• Smallest 1U 300W Supply
• Dual Outputs
• PFC to EN61000-3-2 “A”
• UL, cUL, TUV Approvals
• CE Certified
• FCC Class B Emissions
• Auto Selectable AC Input
• 700W Peak Power
• Four Mechanical Options
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated
atedd output
t t current,
t unless
l otherwise
th i noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Conditions
Autoranging
Input Frequency
Input Current, Full Load
Inrush Current, Cold Start
Leakage Current (Note 1)
Power Factor Correction
Input Protection
Min.
90
180
47
Typ.
100 - 120 VAC
8
200 - 240 VAC
4
110 VAC
220 VAC
240 VAC
1.5
Meets EN61000-3-2 Class A
T8A/250V Fuse
Max.
132
264
63
Units
VAC
Hz
A
35
70
A
mA
Output
Parameter
Output Voltage Adjustment
Output Regulation (Note 2)
Hold Time
Ripple & Noise (20 MHz) (Note 3)
Overload Protection
Over Voltage Protection
Over Temperature Protection
Temperature Coefficient
Transient Recovery Time (Note 4)
Transient Response Deviation
Overshoot/Undershoot
Turn On Delay
Output Short Circuit
Conditions
V1 By Trim Pot
Min.
Typ.
Max.
±5.0
±5.0
110 VAC, 80% Load
20
See Model Selection Guide
Power Limit
130
160
>130% of Rated Output Voltage. Recycle AC Input.
±0.04
2.5
5
50% Load Change
At Turn On/Off
120 VAC
Continuous With Autorecovery
Units
%
%
mSec
%
5.0
1
%/ºC
mS
%
%
S
Max.
Units
General
Parameter
Isolation Voltage (Note 5)
Switching Frequency
MicroPower Direct Interface Signals
292 Page Street
Suite D
Stoughton, MA 02072
USA
Power Supply On
Power Good Signal
Fan Fail
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Conditions
Input - Output
Input - FG (Frame Ground)
Primary - Core
Fixed
Min.
3,000
1,500
1,500
Typ.
VAC
23
kHz
Green LED (LED1) on the PCB
PG on CN1. Goes TTL high 100 to 500 mS after regulation. Goes low at
least 1 mS before the loss of regulation. Will sink 100 mA.
FF on pin 3 of CN1. Open collector output rated for 15 VDC/5 mA sink
current maximum. Goes high if a fan failure is detected
Environmental
Parameter
Operating Temperature Range
Output Derating
Storage Temperature Range
Cooling
Operating Humidity
Conditions
Min.
Typ.
Max.
Ambient
0
+25
+50
2.5%/ ºC from +50 ºC to + 70 ºC
-20
+85
See Model Selection Guide
RH, Non-condensing
90
Units
ºC
ºC
%
Reliability Specifications
Parameter
MTBF
Safety Standards
EEMI Compliance
EMS Immunity Compliance
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 30ºC, Gnd Benign
100
kHours
UL 60950; CSA C22.2 No. 60950; TUV EN60950; CB Report (IEC 60950)
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3
EN6100-4-2,3,4,5,6,8,11; EN55024,; CE Marked (LVD)
Model Selection Guide
Model
Number
MPA300Dx-0512z
MPA300Dx-0524z
MPA300Dx-0548z
MPA300Dx-1224z
Output Voltage
Factory
V1
V2
V1
V2
V1
V2
V1
V2
Max. Output Current (Note 7)
18 CFM
Convection
(U/w Air, E, F)
+5 VDC
+12 VDC
+5 VDC
+24 VDC
+5 VDC
+48 VDC
+12 VDC
+24 VDC
30.00A
16.67A
30.00A
8.33A
30.00A
4.16A
16.67A
8.33A
Notes:
1. Models are available with leakage current specified as low as 500 µA (at
240 VAC) / 300 µA (at 120 VAC). Contact the factory for details.
2. Output regulation includes line & load.
3. Ripple & noise is measured from 10 Hz to 20 MHz. Measurement connection to the unit is made with a 0.1 µF ceramic capacitor & a 22 µF electrolytic
capacitor connected in parallel.
4. Transient recovery is measured to within a 1% error band for a load step
change of 50% to 100%.
5. Isolation specifications are production HI-Pot tested for 3 seconds.
6. The full output range (see table above) is covered in the safety agency certification. Standard models are factory set to the “Preset” voltage. This may be set
(U)
15.00A
11.50
15.00A
5.75A
15.00A
2.60A
12.50A
6.25A
Ripple &
Noise
1% p-p
1% p-p
1% p-p
1% p-p
1% p-p
1% p-p
1% p-p
1% p-p
Input & Output Connector CN2:
Howder Terminal Block No. HB-95-7P or
Mating Molex Part No. 09-91-1600 (16 pin)
Efficiency
(Note 7)
Output Pin Assignment:
75%
75%
Howder
Molex
Pins 1: V1
Pins 1 ~ 3: V1
Pins 2 ~ 3: RTN
Pins 4 ~ 8: RTN
Pin 4: V2
Pins 9 ~ 10: V2
75%
75%
to other levels within the range without affecting the agency
certification. For more information, contact the factory.
7. The maximum continuous output power level, (combined for
V1 & V2) is 300W (with 18 CFM) for the MPA300Dx-1224 &
250W for all other models. For convection cooling, the maximum continuous output power level (combined for V1 & V2) is
150W for the MPA300Dx-1224 & 125W for all other models.
For more information, contact the factory.
8. A 10% minimum load is required to maintain regulation and ripple
specifications.
Pin 5: GND
Pin 12: GND
Pin 6: Neutral
Pin 14: Neutral
Pin 7: Line
Pin 16: Line
Logic Signal Connector CN1:
Mating JST XHP or equivalent (CHYAO
SHIUNN JS-21001-3) Mating Pins: JST
SXH-002T-P0.6 for AWG 30 to 26.
Fan driver connector (FAN2):
12 VDC / 400 mA is available to drive an external
fan. Mating connector is a JST XHP-2 or Molex P/N
48-151-0210 ( 2 pins 0.98 pitch). Mating Pins: JST
SXH-001T-P0.62T or Molex 48150 .
Mechanical Dimensions: U-Chassis (U Suffix)
U-Chassis Cover (C Suffix)
Enclosure With End Fan (E Suffix)
Enclosure With Top Fan (F Suffix)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]