VKP100xT Series OBSOLETE PRODUCT 100 W Watt, att, Dua Dual/Triple al/Triple Out Output, Half Brick DC/DC Converter Contact Factory for Replacement Model FEATURESZ FEAT TURESZ Z 18 - 40 & 33 - 75V INPUT RANGE 2.3" X 2.4" X 0.5" USER CONFIGURABLE AS A SINGLE, DUAL OR TRIPLE OUTPUT EACH CHANNEL INDEPENDENTLY CURRENT LIMITED EXCELLENT CROSS REGULATION 500VDC CHANNEL TO CHANNEL ISOLATION HIGH EFFICIENCY: 88% TYPICAL FIXED-FREQUENCY OPERATION OPERATION TO +100°C BASEPLATE TEMPERATURE 50MS TRANSIENT RECOVERY, 0-90% LOAD STEP PRIMARY & SECONDARY REMOTE ON/OFF ADJUSTABLE OUTPUT VOLTAGE EXTERNAL SYNCHRONIZATION VKP100MT SERIES ARE APPROVED TO UL/CUL1950, EN 60950 DESCRIPTION The VKP100xT Series are members of the VK high density DC/DC converter family. They are multiple output DC/DC converters offered in a 33-75 input voltage range. Their versatile architecture featuring fully isolated channels enables the system designer to utilize the converter in either a single, dual or triple output scheme without excessive minimum load requirements or cross regulation degradation. The VKP100xT's architecture results in an economical and practical solution for use in distributed power schemes for today's demanding telecommunication and electronic data processing applications requiring ground separation between noise sensitive digital logic and bipolar analog components. The VKP100xT's proprietary control circuity responds to 50100% load steps in 35MSeconds to within 1% of nominal Vout. The peak deviation will not exceed 10% of Vout for pulsed load slew rates in excess of 75 Amps per microsecond. The VKP100xT is ideal for electronic data processing applications utilizing modern disk drives and low voltage microprocessors that require dynamic load current response while maintaining tight output voltage tolerances. AGENCY APPROVALS PRODUCT SELECTION CHART VOUT INPUT VOLTAGE MODEL VKP100MT312 VKP100MT315 VKP100MT512 VKP100MT515 I OUT RATED OUTPUT VOLTAGE (VDC) (VDC) Output 1 (±) Output 2 (±) Output 3 (±) 48 3.3 3.3 5.1 5 12 15 12 15 12 15 12 15 (33-75) RATED MAXIMUM OUTPUT CURRENT (A) Output 1 30 30 20 20 Output 2 4.2 3.4 4.2 3.4 Output 3 4.2 3.4 4.2 3.4 For full details go to www.murata-ps.com/rohs www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 VKP100xT.B01 Page 1 of 6 VKP100xT Series 100 Watt, Dual/Triple Output, Half Brick DC/DC Converter INPUT SPECIFICATIONS, ALL MODELS Specifications are at T PARAMETER Input Fusing Voltage Range VKP100MT Series Reflected Ripple Current Input Ripple Rejection Maximum Input Current VKP100MT Series No Load Power Dissipation Inrush Charge VKP100MT Series Quiescent Operating Current Primary On/Off Disabled CONDITIONS MIN Peak - Peak DC to 1KHz Output Power = 100W VIN = 30V POUT = 0, VIN, Min<VIN<VIN, Max CASE = +40°C nominal input voltage unless other- TYP 33 48 50 60 ISOLATION Input to Each Output Input to Baseplate Channel to Channel Resistance, Input - Output Capacitance, Input - Output Leakage Current GENERAL Set Point Accuracy Turn-on Time Remote On/Off Control Inputs Primary Sink Current-Logic Low Vlow Vhigh Secondary Sink Current-Logic Low Vlow Vhigh External Synchronization Input Frequency Pulse Width Source Impedence Input High Voltage Input Low Voltage Input Impedance Switching Frequency Weight TEMPERATURE Operation/Specification Storage Shutdown Thermal Inpedance MIN Peak Test 1500 1500 500 10 Set Point Voltage Output Current, IOUT Output Ripple, p-p Output Adjust Range Output Temperature Drift Line Regulation Load Regulation Current Limit Inception Short-Circuit Current Transient Response Peak Deviation Settling Time Overvoltage Limit Efficiency www.murata-ps.com 75 370 VDC mA dB 5 6 A W 0.247 mC 10 mA 20 mA CASE = +40°C nominal input voltage unless TYP MAX UNITS 2000 VDC VDC VDC M7 pF VISO = 240VAC, 60Hz 180 MA, rms VIN = Nominal, 50% Load Within 1% of Nominal VOUT 3.5 Any Channel to Any Channel Open Collector/Drain VIN = VMAX 1 5 % mSec 7 0.8 Open Collector mA V 100 0.4 Open Collector MA V 520 320 47 5 1 Open Collector/Drain 440 150 490 KHz nSec 7 V V 7 KHz 3 (85) oz (g) +100 +125 +115 oC °C °C °C/W 4 0 470 480 470 Case Temperature -40 -55 +100 Case to Ambient 8.2 VKP100MT312 OUTPUT SPECIFICATIONS Specifications are at T PARAMETER Output Power A 15 COMMON SPECIFICATIONS, ALL MODELS Specifications are at T CONDITIONS UNITS 10 7.5 Secondary On/Off Disabled PARAMETER MAX CONDITIONS Total Combined O/P Power = 100 Watts Max IO Nom Min 0.5 DC to 20MHz* * OUTPUT 1 Nom Max 50 3.3 15 100 Other Outputs Min Load 100 0 OUTPUT 2 Nom Max 25 12.2 2.1 150 = +40°C nominal input voltage unless Min 50 25 12.2 2.1 150 50 4.2 500 .02 .05 UNITS W V A mV V %/°C .02 0.05 0.50 0.10 1.00 1.0 2.0 See Regulation Curves 1.0 2.0 See Regulation Curves % % 38 30 38 6.0 5.0 6.0 5.0 A A .02 4.2 0 500 Dependent on V1 .05 OUTPUT 3 Nom Max 30.0 200 3.80 .05 3.15 VIN, MinbVINbVIN, Max IO = IO, Nom Min Load to Rated Load Min CASE 6.0 6.0 50 to 100% Load Step 150 35 VOUT, 1% of VOUT, Nom IOUT1=15A, (IOUT2+IOUT3)= 4.2A F.L. VIN=Nominal 4.2 85 86 250 50 5.0 mV MSec V % Technical enquiries - email: [email protected], tel: +1 508 339 3000 VKP100xT.B01 Page 2 of 6 VKP100xT Series 100 Watt, Dual/Triple Output, Half Brick DC/DC Converter VKP100MT315 OUTPUT SPECIFICATIONS Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified. PARAMETER Output Power Set Point Voltage Output Current, IOUT Output Ripple, p-p Output Adjust Range CONDITIONS Total Combined O/P Power = Min 100 Watts Maximum IO Nom 0.5 DC to 20MHz* * Load Regulation Current Limit Inception VIN, MinbVINbVIN, Max IO = IO, Nom Min Load to Rated Load Other Outputs Min Load Short-Circuit Current Transient Response 50 to 100% Load Step Peak Deviation Settling Time VOUT, 1% of VOUT, Nom Overvoltage Limit Efficiency IOUT1=15A, (IOUT2+IOUT3) = 3.4A F.L. VIN=Nominal 4.2 85 Min OUTPUT 2 Nom Max 25 15.85 Min OUTPUT 3 Nom Max 100 15 100 30.0 200 3.80 .02 .05 .02 0.05 0.50 38 0.10 1.0 1.0 2.0 See Regulation Curves 1.0 2.0 See Regulation Curves 5.0 5.0 30 38 150 35 250 50 mV MSec 5.0 V % 0 1.66 125 4.0 50 UNITS 50 3.3 3.15 Output Temperature Drift Line Regulation OUTPUT 1 Nom Max 3.33 0 500 Dependent on V1 .05 5.0 25 15.85 50 W V 1.66 125 3.33 500 A mV V .02 .05 %/°C 4.0 5.0 86 VKP100MT512 OUTPUT SPECIFICATIONS % % A A Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified. PARAMETER Output Power Set Point Voltage Output Current, IOUT Output Ripple, p-p Output Adjust Range Output Temperature Drift Line Regulation Load Regulation Current Limit Inception Short-Circuit Current Transient Response Peak Deviation Settling Time Overvoltage Limit Efficiency CONDITIONS Total Combined O/P Power = Min 100 Watts Combined IO Nom 50 0.5 DC to 20MHz* * OUTPUT 1 Nom Max 5.1 10 100 4.75 VIN, MinbVINbVIN, Max IO = IO, Nom Min Load to Rated Load Other Outputs Min Load Min 100 20 150 5.50 OUTPUT 2 Nom Max 25 0 12 2.1 150 OUTPUT 3 Nom Max Min 50 4.2 0 500 Dependent on V1 .05 UNITS 25 50 W 12 2.1 150 4.2 500 V A mV V .02 .05 %/°C .02 .05 .02 0.05 0.50 0.10 1.0 1.0 2.0 See Regulation Curves 1.0 2.0 See Regulation Curves % % 26.0 20.0 26.0 6.0 5.0 6.0 5.0 A A 200 300 mV 35 50 7.0 MSec V % 6.0 6.0 50 to 100% Load Step VOUT, 1% of VOUT, Nom IOUT1=10A, (IOUT2+IOUT3) = 4.2A F.L. VIN=Nominal 6.0 86 87 VKP100MT515 OUTPUT SPECIFICATIONS Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified. PARAMETER Output Power Set Point Voltage Output Current, IOUT Output Ripple, p-p Output Adjust Range Output Temperature Drift Line Regulation Load Regulation Current Limit Inception Short-Circuit Current Transient Response Peak Deviation Settling Time Overvoltage Limit Efficiency CONDITIONS Total Combined O/P Power = 100 Watts Max IO Nom Min 50 Min 100 10 100 4.60 .02 OUTPUT 2 Nom Max 25 5.0 0.5 DC to 20MHz* * OUTPUT 1 Nom Max Min OUTPUT 3 Nom Max 50 25 15.3 20 150 5.50 .05 0 1.66 125 .02 50 15.3 3.33 0 500 Dependent on V1 .05 UNITS W V 1.66 125 3.33 500 .02 .05 A mV V %/°C VIN, MinbVINbVIN, Max IO = IO, Nom Min Load to Rated Load Other Outputs Min Load 0.05 0.05 26.0 20.0 1.0 1.0 26.0 1.0 2.0 See Regulation Curves 5.0 4.0 5.0 1.0 2.0 See Regulation Curves 5.0 4.0 5.0 % % A A 50 to 100% Load Step 200 35 VOUT, 1% of VOUT, Nom IOUT1=10A, (IOUT2+IOUT3) = 4.2A F.L. VIN=Nominal 6.0 86 87 300 50 7.0 mV MSec V % *See Application Notes available on the web at www.cdpowerelectronics.com www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 VKP100xT.B01 Page 3 of 6 VKP100xT Series 100 Watt, Dual/Triple Output, Half Brick DC/DC Converter TYPICAL PERFORMANCE CURVE ABSOLUTE MAXIMUM RATINGS Output Short-Circuit Duration ..................................... Continuous Baseplate Temperature .................................................... +100°C Lead Temperature (soldering, 10 seconds max) .............. +300°C Storage Temperature ....................................................... +125°C Input to Output Isolation ............................................... 1500 VDC www.murata-ps.com TCASE = +40°C, nominal input voltage, nominal load, recommended external components applied, unless otherwise specified. ORDERING INFORMATION VKP100 MTYZ - L Device Family Indicates 100 Watt Regulated Unit Model Number Selected from Table of Electrical Characteristics Where: X = Input Voltage (M = 48VDC) T = Number of Outputs (Triple "T") Y = 3 for 3.3V, 5 for 5V Z = 12 for 12V, 15 for 15V Lead Length 0.250" - No Number 0.145" - (6) 0.110" - (8) Technical enquiries - email: [email protected], tel: +1 508 339 3000 VKP100xT.B01 Page 4 of 6 VKP100xT Series 100 Watt, Dual/Triple Output, Half Brick DC/DC Converter TYPICAL PERFORMANCE CURVE TCASE = +40°C, nominal input voltage, nominal load, recommended external components applied, unless otherwise specified. VKP100xT312 VKP100xT315 VKP100xT512 VKP100xT515 www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 VKP100xT.B01 Page 5 of 6 VKP100xT Series 100 Watt, Dual/Triple Output, Half Brick DC/DC Converter MECHANICAL NOTES: All dimensions are in inches (millimeters). PIN PLACEMENT TOLERANCE: ± 0.005" MECHANICAL TOLERANCE: ± 0.015" Marked with: specific model ordered, date code, job code. MATERIAL: Units are encapsulated in a low thermal resistance molding compound which has excellent chemical resistance and electrical properties in high humidity environments and over a wide operating temperature range. The encapsulant and outer shell of the unit have UL94V-0 ratings. Lead material is solder plated to allow ease of solderability. *See Ordering Information on page 4 for available lead lengths. PIN CONNECTIONS 1 2 PRIMARY ON/OFF -VIN 3 4 5 6 7 8 9 10 11 12 +VIN SYNC IN -V2 +V2 TRIM +V1 -V1 SECONDARY ON/OFF +V3 -V3 USA: Tucson (Az), Tel: (800) 547 2537, email: [email protected] Canada: Toronto, Tel: (866) 740 1232, email: [email protected] Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 UK: Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected] France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected] Germany: München, Tel: +49 (0)89-544334-0, email: [email protected] www.murata-ps.com email: [email protected] ISO 9001 REGISTERED Japan: Tokyo, Tel: 3-3779-1031, email: [email protected] Osaka, Tel: 6-6354-2025, email: [email protected] Website: www.murata-ps.jp China: Shanghai, Tel: +86 215 027 3678, email: [email protected] Guangzhou, Tel: +86 208 221 8066, email: [email protected] 07/28/08 Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2008 Murata Power Solutions, Inc. www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 VKP100xT.B01 Page 6 of 6