VKP100MTC Series V OBSOLETE PRODUCT 100 Watt, Du Dual/Triple ual/Triplee Output, Ou Half Brick DC/DC Converter Contact Factory for Replacement Model FEATURES FEAT TURES S ROH HS S COMPL COMPLIANT LIA 33 - 75V INPUT RANGE 2.3" X 2.4" X 0.5" USER CONFIGURABLE AS A SINGLE, DUAL OR TRIPLE OUTPUT EACH CHANNEL INDEPENDENTLY CURRENT LIMITED EXCELLENT CROSS REGULATION 500VDC CHANNEL TO CHANNEL ISOLATION HIGH EFFICIENCY: 88% TYPICAL FIXED-FREQUENCY OPERATION OPERATION TO +100°C BASEPLATE TEMPERATURE 50MS TRANSIENT RECOVERY, 0-90% LOAD STEP PRIMARY & SECONDARY REMOTE ON/OFF ADJUSTABLE OUTPUT VOLTAGE EXTERNAL SYNCHRONIZATION APPROVED TO UL/CUL1950, EN 60950 DESCRIPTION The VKP100MTC Series are members of the VK high density DC/DC converter family. They are multiple output DC/DC converters offered in a 33-75 input voltage range. Their versatile architecture featuring fully isolated channels enables the system designer to utilize the converter in either a single, dual or triple output scheme without excessive minimum load requirements or cross regulation degradation. The VKP100MTC's architecture results in an economical and practical solution for use in distributed power schemes for today's demanding telecommunication and electronic data processing applications requiring ground separation between noise sensitive digital logic and bipolar analog components. The VKP100xTC's proprietary control circuity responds to 50-100% load steps in 35MSeconds to within 1% of nominal Vout. The peak deviation will not exceed 10% of Vout for pulsed load slew rates in excess of 75 Amps per microsecond. The VKP100MTC is ideal for electronic data processing applications utilizing modern disk drives and low voltage microprocessors that require dynamic load current response while maintaining tight output voltage tolerances. AGENCY APPROVALS PRODUCT SELECTION CHART VOUT INPUT VOLTAGE I OUT RATED OUTPUT VOLTAGE (VDC) MODEL (VDC) Output 1 (±) Output 2 (±) Output 3 (±) VKP100MT312C VKP100MT315C VKP100MT512C VKP100MT515C 48 3.3 3.3 5.1 5 12 15 12 15 12 15 12 15 (33-75) RATED MAXIMUM OUTPUT CURRENT (A) Output 1 30 30 20 20 Output 2 4.2 3.4 4.2 3.4 Output 3 4.2 3.4 4.2 3.4 ISO9001 CERTIFIED For full details go to www.murata-ps.com/rohs www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 VKP100MTC.B01 Page 1 of 6 VKP100MTC Series 100 Watt, Dual/Triple Output, Half Brick DC/DC Converter INPUT SPECIFICATIONS, ALL MODELS Specifications are at T CASE PARAMETER Input Fusing Voltage Range VKP100MTC Series Reflected Ripple Current Input Ripple Rejection Maximum Input Current VKP100MTC Series No Load Power Dissipation Inrush Charge VKP100MTC Series Quiescent Operating Current Primary On/Off Disabled CONDITIONS MIN Peak - Peak DC to 1KHz Output Power = 100W VIN = 30V POUT = 0, VIN, Min<VIN<VIN, Max = +40°C nominal input voltage unless otherwise specified. TYP MAX UNITS 33 48 50 60 PARAMETER ISOLATION Input to Each Output Input to Baseplate Channel to Channel Resistance, Input - Output Capacitance, Input - Output Leakage Current GENERAL Set Point Accuracy Turn-on Time Remote On/Off Control Inputs Primary Sink Current-Logic Low Vlow Vhigh Secondary Sink Current-Logic Low Vlow Vhigh External Synchronization Input Frequency Pulse Width Source Impedence Input High Voltage Input Low Voltage Input Impedance Switching Frequency Weight TEMPERATURE Operation/Specification Storage Shutdown Thermal Inpedance CONDITIONS MIN Peak Test 1500 1500 500 10 Load Regulation Current Limit Inception Short-Circuit Current Transient Response Peak Deviation Settling Time Overvoltage Limit Efficiency www.murata-ps.com VDC mA dB 5 6 A W 0.247 mC 10 mA 20 mA = +40°C nominal input voltage unless otherwise specified. TYP MAX UNITS CASE 2000 VDC VDC VDC M7 pF VISO = 240VAC, 60Hz 180 MA, rms VIN = Nominal, 50% Load Within 1% of Nominal VOUT 3.5 Any Channel to Any Channel Open Collector/Drain VIN = VMAX 1 5 % mSec 7 0.8 Open Collector mA V 100 0.4 Open Collector MA V 520 320 47 5 1 KHz nSec 7 V V 7 KHz oz (g) Open Collector/Drain 440 150 4 0 470 480 470 490 3 (85) Case Temperature -40 -55 +100 Case to Ambient CONDITIONS Total Combined O/P Power = 100 Watts Max IO Nom 8.2 = +40°C nominal input voltage unless otherwise specified. OUTPUT 1 Min Nom Max OUTPUT 2 Min Nom Max 50 3.3 15 100 25 12.2 2.1 150 0.5 DC to 20MHz* * oC °C °C °C/W +100 +125 +115 CASE Set Point Voltage Output Current, IOUT Output Ripple, p-p Output Adjust Range Output Temperature Drift Line Regulation 75 370 15 VKP100MT312C OUTPUT SPECIFICATIONS Specifications are at T PARAMETER Output Power A 7.5 Secondary On/Off Disabled COMMON SPECIFICATIONS, ALL MODELS Specifications are at T 10 Other Outputs Min Load 0 50 25 12.2 2.1 150 50 4.2 500 .02 .05 UNITS W V A mV V %/°C .02 0.05 0.50 0.10 1.00 1.0 2.0 See Regulation Curves 1.0 2.0 See Regulation Curves % % 38 30 38 6.0 5.0 6.0 5.0 A A .02 4.2 0 500 Dependent on V1 .05 OUTPUT 3 Nom Max 30.0 200 3.80 .05 3.15 VIN, MinbVINbVIN, Max IO = IO, Nom Min Load to Rated Load 100 Min 6.0 6.0 50 to 100% Load Step 150 35 VOUT, 1% of VOUT, Nom IOUT1=15A, (IOUT2+IOUT3)= 4.2A F.L. VIN=Nominal 4.2 85 86 250 50 5.0 mV MSec V % Technical enquiries - email: [email protected], tel: +1 508 339 3000 VKP100MTC.B01 Page 2 of 6 VKP100MTC Series 100 Watt, Dual/Triple Output, Half Brick DC/DC Converter VKP100MT315C OUTPUT SPECIFICATIONS Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified. OUTPUT 1 PARAMETER Output Power Set Point Voltage CONDITIONS Total Combined O/P Power = 100 Watts Maximum IO Nom Output Current, IOUT Output Ripple, p-p Output Adjust Range Output Temperature Drift Line Regulation Load Regulation Current Limit Inception Short-Circuit Current Transient Response Min Overvoltage Limit Efficiency Max 50 100 Min 3.3 0.5 OUTPUT 3 Nom Max 25 50 Min 15.85 UNITS 25 50 W 1.66 3.33 A 125 500 mV V .02 .05 %/°C 15.85 3.33 0 V 100 200 3.80 125 .02 .05 .02 IO = IO, Nom 0.05 0.10 Min Load to Rated Load Other Outputs Min Load 0.50 38 1.0 1.0 2.0 See Regulation Curves 1.0 2.0 See Regulation Curves 5.0 5.0 30 38 150 250 mV 35 50 MSec 5.0 V % 3.15 1.66 Max 30.0 DC to 20MHz* * 0 Nom 15 500 Dependent on V1 .05 VIN, MinbVINbVIN, Max 4.0 5.0 4.0 5.0 % % A A 50 to 100% Load Step Peak Deviation Settling Time OUTPUT 2 Nom VOUT, 1% of VOUT, Nom IOUT1=15A, (IOUT2+IOUT3) = 3.4A F.L. VIN=Nominal 4.2 85 86 VKP100MT512C OUTPUT SPECIFICATIONS PARAMETER Output Power Set Point Voltage CONDITIONS Total Combined O/P Power = 100 Watts Combined IO Nom Output Current, IOUT Output Ripple, p-p Output Adjust Range Output Temperature Drift Line Regulation Load Regulation Current Limit Inception Short-Circuit Current Transient Response Peak Deviation Settling Time Overvoltage Limit Efficiency Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified. OUTPUT 1 OUTPUT 2 OUTPUT 3 Min Nom Max Min Nom Max Min Nom Max UNITS 50 0.5 DC to 20MHz* * 100 25 5.1 Other Outputs Min Load 25 0 2.1 150 50 12 4.2 0 500 Dependent on V1 W V 10 100 20 150 5.50 .02 .05 .02 0.05 0.50 0.10 1.0 1.0 2.0 See Regulation Curves 1.0 2.0 See Regulation Curves % % 26.0 20.0 26.0 6.0 5.0 6.0 5.0 A A 200 300 mV 35 50 7.0 MSec V % 4.75 VIN, MinbVINbVIN, Max IO = IO, Nom Min Load to Rated Load 50 12 .05 6.0 2.1 150 4.2 500 A mV V .02 .05 %/°C 6.0 50 to 100% Load Step VOUT, 1% of VOUT, Nom IOUT1=10A, (IOUT2+IOUT3) = 4.2A F.L. VIN=Nominal 6.0 86 87 VKP100MT515C OUTPUT SPECIFICATIONS PARAMETER Output Power Set Point Voltage Output Current, IOUT Output Ripple, p-p Output Adjust Range Output Temperature Drift Line Regulation Load Regulation Current Limit Inception Short-Circuit Current Transient Response Peak Deviation Settling Time Overvoltage Limit Efficiency CONDITIONS Total Combined O/P Power = 100 Watts Max IO Nom Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified. OUTPUT 1 OUTPUT 2 OUTPUT 3 Min Nom Max Min Nom Max Min Nom Max UNITS 50 0.5 DC to 20MHz* * 5.0 10 100 4.60 .02 100 20 150 5.50 .05 25 0 15.3 1.66 125 .02 50 3.33 0 500 Dependent on V1 .05 25 50 15.3 1.66 125 3.33 500 .02 .05 W V A mV V %/°C VIN, MinbVINbVIN, Max IO = IO, Nom Min Load to Rated Load Other Outputs Min Load 0.05 0.05 26.0 20.0 1.0 1.0 1.0 2.0 See Regulation Curves 26.0 200 300 mV 35 50 7.0 MSec V % 5.0 4.0 5.0 1.0 2.0 See Regulation Curves 5.0 4.0 5.0 % % A A 50 to 100% Load Step VOUT, 1% of VOUT, Nom IOUT1=10A, (IOUT2+IOUT3) = 4.2A F.L. VIN=Nominal 6.0 86 87 *See Application Notes available on the web at www.cd4power.com www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 VKP100MTC.B01 Page 3 of 6 VKP100MTC Series 100 Watt, Dual/Triple Output, Half Brick DC/DC Converter TYPICAL PERFORMANCE CURVE ABSOLUTE MAXIMUM RATINGS Output Short-Circuit Duration ..................................... Continuous Baseplate Temperature .................................................... +100°C Lead Temperature (soldering, 10 seconds max) .............. +300°C Storage Temperature ....................................................... +125°C Input to Output Isolation ............................................... 1500 VDC www.murata-ps.com TCASE = +40°C, nominal input voltage, nominal load, recommended external components applied, unless otherwise specified. (Refer to Application Note DCAN-9 at www.cd4power.com) ORDERING INFORMATION VKP100 MTYZ - L C Device Family Indicates 100 Watt Regulated Unit Model Number Selected from Table of Electrical Characteristics Where: X = Input Voltage (M = 48VDC) T = Number of Outputs (Triple "T") Y = 3 for 3.3V, 5 for 5V Z = 12 for 12V, 15 for 15V Lead Length 0.250" - No Number 0.145" - (6) 0.110" - (8) RoHS Compliant Technical enquiries - email: [email protected], tel: +1 508 339 3000 VKP100MTC.B01 Page 4 of 6 VKP100MTC Series 100 Watt, Dual/Triple Output, Half Brick DC/DC Converter TYPICAL PERFORMANCE CURVE TCASE = +40°C, nominal input voltage, nominal load, recommended external components applied, unless otherwise specified. (Refer to Application Note DCAN-9 at www.cd4power.com) FULL LOAD EFFICIENCY vs LOAD DISTRIBUTION EFFICIENCY vs OUTPUT LOAD 90 VIN = MIN. VIN = NOM. VIN = MAX. Output Voltage |(V)| 85 Efficiency (%) Efficiency (%) 20 VIN = MIN 85 VKP100xT312C LOAD REGULATION 90 80 VIN = MAX 80 75 75 15 14.0 12.2 11.0 10 5 3.3V 3.0/0.8 6.0/1.7 9.0/2.5 1 2 / 3 . 3 Iout1/(Iout2 + Iout3)(A) 70 0.5/8.4 15/4.2 VIN = MIN. VIN = NOM. VIN = MAX. 80 18 85 VIN = MAX 80 75 75 30/0 20 VIN = MIN Efficiency (%) 85 15/4.2 Iout1/(Iout2 + Iout3)(A) LOAD REGULATION 90 90 Efficiency (%) 0 0.5/8.4 30/0 FULL LOAD EFFICIENCY vs LOAD DISTRIBUTION EFFICIENCY vs OUTPUT LOAD VKP100xT315C 15/4.2 Iout1/(Iout2 + Iout3)(A) Output Voltage |(V)| 70 0.50/0 15.9 15 14.5 10 5 3.3V 70 0.5/6.8 15/3.4 VIN = MIN. VIN = NOM. VIN = MAX. Efficiency (%) Efficiency (%) 2.0/0.8 4.0/1.7 6.0/2.5 8.0/3.3 Iout1/(Iout2 + Iout3)(A) 90 70 0.5/8.4 10/4.2 10/3.4 20/0 20 VIN = MIN 80 70 0.5/6.8 10/4.2 Iout1/(Iout2 + Iout3)(A) LOAD REGULATION 75 75 12.0 10 0 0.5/8.4 20/0 VIN = MAX Efficiency (%) Efficiency (%) 10/4.2 Iout1/(Iout2 + Iout3)(A) 85 80 www.murata-ps.com 13.2 10.5 5.1 90 VIN = MIN. VIN = NOM. VIN = MAX. 2.0/0.9 4.0/1.4 6.0/2.0 8.0/2.7 Iout1/(Iout2 + Iout3)(A) 15 FULL LOAD EFFICIENCY vs LOAD DISTRIBUTION 85 70 0.50/0 VIN = MAX 80 EFFICIENCY vs OUTPUT LOAD VKP100xT515C 20 75 75 70 0.50/0 30/0 VIN = MIN 85 80 15/3.4 Iout1/(Iout2 + Iout3)(A) LOAD REGULATION 90 85 VKP100xT512C 0 0.5/6.8 30/0 FULL LOAD EFFICIENCY vs LOAD DISTRIBUTION EFFICIENCY vs OUTPUT LOAD 90 15/3.4 Iout1/(Iout2 + Iout3)(A) Output Voltage |(V)| 3.0/0.7 6.0/1.4 9.0/2.0 12/2.9 Iout1/(Iout2 + Iout3)(A) Output Voltage |(V)| 70 0.50/0 15 16.7 15.3 13.9 10 5 10/3.4 Iout1/(Iout2 + Iout3)(A) 20/0 0 0.5/6.8 10/3.4 Iout1/(Iout2 + Iout3)(A) 20/0 Technical enquiries - email: [email protected], tel: +1 508 339 3000 VKP100MTC.B01 Page 5 of 6 VKP100MTC Series 100 Watt, Dual/Triple Output, Half Brick DC/DC Converter MECHANICAL SIDE VIEW TOP VIEW NOTES: All dimensions are in inches (millimeters). PIN PLACEMENT TOLERANCE: ± 0.005" MECHANICAL TOLERANCE: ± 0.015" Marked with: specific model ordered, date code, job code. MATERIAL: Units are encapsulated in a low thermal resistance molding compound which has excellent chemical resistance and electrical properties in high humidity environments and over a wide operating temperature range. The encapsulant and outer shell of the unit have UL94V-0 ratings. Lead material is solder plated to allow ease of solderability. *See Ordering Information on page 4 for available lead lengths. PIN CONNECTIONS 1 2 PRIMARY ON/OFF -VIN 3 4 5 6 7 8 9 10 11 12 +VIN SYNC IN -V2 +V2 TRIM +V1 -V1 SECONDARY ON/OFF +V3 -V3 USA: Tucson (Az), Tel: (800) 547 2537, email: [email protected] Canada: Toronto, Tel: (866) 740 1232, email: [email protected] Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 UK: Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected] France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected] Germany: München, Tel: +49 (0)89-544334-0, email: [email protected] www.murata-ps.com email: [email protected] ISO 9001 REGISTERED Japan: Tokyo, Tel: 3-3779-1031, email: [email protected] Osaka, Tel: 6-6354-2025, email: [email protected] Website: www.murata-ps.jp China: Shanghai, Tel: +86 215 027 3678, email: [email protected] Guangzhou, Tel: +86 208 221 8066, email: [email protected] 07/28/08 Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2008 Murata Power Solutions, Inc. www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 VKP100MTC.B01 Page 6 of 6