MURATA-PS VKP100MT312C

VKP100MTC Series
V
OBSOLETE PRODUCT
100 Watt, Du
Dual/Triple
ual/Triplee Output,
Ou
Half Brick DC/DC Converter
Contact Factory for Replacement Model
FEATURES
FEAT
TURES
S
ROH
HS
S COMPL
COMPLIANT
LIA
33 - 75V INPUT RANGE
2.3" X 2.4" X 0.5"
USER CONFIGURABLE AS A SINGLE, DUAL OR
TRIPLE OUTPUT
EACH CHANNEL INDEPENDENTLY CURRENT LIMITED
EXCELLENT CROSS REGULATION
500VDC CHANNEL TO CHANNEL ISOLATION
HIGH EFFICIENCY: 88% TYPICAL
FIXED-FREQUENCY OPERATION
OPERATION TO +100°C BASEPLATE TEMPERATURE
50MS TRANSIENT RECOVERY, 0-90% LOAD STEP
PRIMARY & SECONDARY REMOTE ON/OFF
ADJUSTABLE OUTPUT VOLTAGE
EXTERNAL SYNCHRONIZATION
APPROVED TO UL/CUL1950, EN 60950
DESCRIPTION
The VKP100MTC Series are members of the VK high density
DC/DC converter family. They are multiple output DC/DC converters offered in a 33-75 input voltage range. Their versatile
architecture featuring fully isolated channels enables the system
designer to utilize the converter in either a single, dual or triple
output scheme without excessive minimum load requirements
or cross regulation degradation.
The VKP100MTC's architecture results in an economical
and practical solution for use in distributed power schemes
for today's demanding telecommunication and electronic data
processing applications requiring ground separation between
noise sensitive digital logic and bipolar analog components. The
VKP100xTC's proprietary control circuity responds to 50-100%
load steps in 35MSeconds to within 1% of nominal Vout. The
peak deviation will not exceed 10% of Vout for pulsed load
slew rates in excess of 75 Amps per microsecond.
The VKP100MTC is ideal for electronic data processing
applications utilizing modern disk drives and low voltage
microprocessors that require dynamic load current response
while maintaining tight output voltage tolerances.
AGENCY APPROVALS
PRODUCT SELECTION CHART
VOUT
INPUT
VOLTAGE
I OUT
RATED OUTPUT VOLTAGE (VDC)
MODEL
(VDC)
Output 1 (±)
Output 2 (±)
Output 3 (±)
VKP100MT312C
VKP100MT315C
VKP100MT512C
VKP100MT515C
48
3.3
3.3
5.1
5
12
15
12
15
12
15
12
15
(33-75)
RATED MAXIMUM OUTPUT CURRENT (A)
Output 1
30
30
20
20
Output 2
4.2
3.4
4.2
3.4
Output 3
4.2
3.4
4.2
3.4
ISO9001
CERTIFIED
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries - email: [email protected], tel: +1 508 339 3000
VKP100MTC.B01 Page 1 of 6
VKP100MTC Series
100 Watt, Dual/Triple Output, Half Brick DC/DC Converter
INPUT SPECIFICATIONS, ALL MODELS Specifications are at T
CASE
PARAMETER
Input Fusing
Voltage Range
VKP100MTC Series
Reflected Ripple Current
Input Ripple Rejection
Maximum Input Current
VKP100MTC Series
No Load Power Dissipation
Inrush Charge
VKP100MTC Series
Quiescent Operating Current
Primary On/Off Disabled
CONDITIONS
MIN
Peak - Peak
DC to 1KHz
Output Power = 100W
VIN = 30V
POUT = 0, VIN, Min<VIN<VIN, Max
= +40°C nominal input voltage unless otherwise specified.
TYP
MAX
UNITS
33
48
50
60
PARAMETER
ISOLATION
Input to Each Output
Input to Baseplate
Channel to Channel
Resistance, Input - Output
Capacitance, Input - Output
Leakage Current
GENERAL
Set Point Accuracy
Turn-on Time
Remote On/Off Control Inputs
Primary
Sink Current-Logic Low
Vlow
Vhigh
Secondary
Sink Current-Logic Low
Vlow
Vhigh
External Synchronization Input
Frequency
Pulse Width
Source Impedence
Input High Voltage
Input Low Voltage
Input Impedance
Switching Frequency
Weight
TEMPERATURE
Operation/Specification
Storage
Shutdown
Thermal Inpedance
CONDITIONS
MIN
Peak Test
1500
1500
500
10
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Peak Deviation
Settling Time
Overvoltage Limit
Efficiency
www.murata-ps.com
VDC
mA
dB
5
6
A
W
0.247
mC
10
mA
20
mA
= +40°C nominal input voltage unless otherwise specified.
TYP
MAX
UNITS
CASE
2000
VDC
VDC
VDC
M7
pF
VISO = 240VAC, 60Hz
180
MA, rms
VIN = Nominal, 50% Load
Within 1% of Nominal VOUT
3.5
Any Channel to Any Channel
Open Collector/Drain
VIN = VMAX
1
5
%
mSec
7
0.8
Open Collector
mA
V
100
0.4
Open Collector
MA
V
520
320
47
5
1
KHz
nSec
7
V
V
7
KHz
oz (g)
Open Collector/Drain
440
150
4
0
470
480
470
490
3 (85)
Case Temperature
-40
-55
+100
Case to Ambient
CONDITIONS
Total Combined O/P Power =
100 Watts Max
IO Nom
8.2
= +40°C nominal input voltage unless otherwise specified.
OUTPUT 1
Min
Nom
Max
OUTPUT 2
Min
Nom
Max
50
3.3
15
100
25
12.2
2.1
150
0.5
DC to 20MHz*
*
oC
°C
°C
°C/W
+100
+125
+115
CASE
Set Point Voltage
Output Current, IOUT
Output Ripple, p-p
Output Adjust Range
Output Temperature Drift
Line Regulation
75
370
15
VKP100MT312C OUTPUT SPECIFICATIONS Specifications are at T
PARAMETER
Output Power
A
7.5
Secondary On/Off Disabled
COMMON SPECIFICATIONS, ALL MODELS Specifications are at T
10
Other Outputs Min Load
0
50
25
12.2
2.1
150
50
4.2
500
.02
.05
UNITS
W
V
A
mV
V
%/°C
.02
0.05
0.50
0.10
1.00
1.0
2.0
See Regulation Curves
1.0
2.0
See Regulation Curves
%
%
38
30
38
6.0
5.0
6.0
5.0
A
A
.02
4.2
0
500
Dependent on V1
.05
OUTPUT 3
Nom
Max
30.0
200
3.80
.05
3.15
VIN, MinbVINbVIN, Max
IO = IO, Nom
Min Load to Rated Load
100
Min
6.0
6.0
50 to 100% Load Step
150
35
VOUT, 1% of VOUT, Nom
IOUT1=15A, (IOUT2+IOUT3)= 4.2A
F.L. VIN=Nominal
4.2
85
86
250
50
5.0
mV
MSec
V
%
Technical enquiries - email: [email protected], tel: +1 508 339 3000
VKP100MTC.B01 Page 2 of 6
VKP100MTC Series
100 Watt, Dual/Triple Output, Half Brick DC/DC Converter
VKP100MT315C OUTPUT SPECIFICATIONS
Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified.
OUTPUT 1
PARAMETER
Output Power
Set Point Voltage
CONDITIONS
Total Combined O/P Power =
100 Watts Maximum
IO Nom
Output Current, IOUT
Output Ripple, p-p
Output Adjust Range
Output Temperature Drift
Line Regulation
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Min
Overvoltage Limit
Efficiency
Max
50
100
Min
3.3
0.5
OUTPUT 3
Nom
Max
25
50
Min
15.85
UNITS
25
50
W
1.66
3.33
A
125
500
mV
V
.02
.05
%/°C
15.85
3.33
0
V
100
200
3.80
125
.02
.05
.02
IO = IO, Nom
0.05
0.10
Min Load to Rated Load
Other Outputs Min Load
0.50
38
1.0
1.0
2.0
See Regulation Curves
1.0
2.0
See Regulation Curves
5.0
5.0
30
38
150
250
mV
35
50
MSec
5.0
V
%
3.15
1.66
Max
30.0
DC to 20MHz*
*
0
Nom
15
500
Dependent on V1
.05
VIN, MinbVINbVIN, Max
4.0
5.0
4.0
5.0
%
%
A
A
50 to 100% Load Step
Peak Deviation
Settling Time
OUTPUT 2
Nom
VOUT, 1% of VOUT, Nom
IOUT1=15A, (IOUT2+IOUT3) = 3.4A
F.L. VIN=Nominal
4.2
85
86
VKP100MT512C OUTPUT SPECIFICATIONS
PARAMETER
Output Power
Set Point Voltage
CONDITIONS
Total Combined O/P Power =
100 Watts Combined
IO Nom
Output Current, IOUT
Output Ripple, p-p
Output Adjust Range
Output Temperature Drift
Line Regulation
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Peak Deviation
Settling Time
Overvoltage Limit
Efficiency
Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified.
OUTPUT 1
OUTPUT 2
OUTPUT 3
Min
Nom
Max
Min
Nom
Max
Min
Nom
Max
UNITS
50
0.5
DC to 20MHz*
*
100
25
5.1
Other Outputs Min Load
25
0
2.1
150
50
12
4.2
0
500
Dependent on V1
W
V
10
100
20
150
5.50
.02
.05
.02
0.05
0.50
0.10
1.0
1.0
2.0
See Regulation Curves
1.0
2.0
See Regulation Curves
%
%
26.0
20.0
26.0
6.0
5.0
6.0
5.0
A
A
200
300
mV
35
50
7.0
MSec
V
%
4.75
VIN, MinbVINbVIN, Max
IO = IO, Nom
Min Load to Rated Load
50
12
.05
6.0
2.1
150
4.2
500
A
mV
V
.02
.05
%/°C
6.0
50 to 100% Load Step
VOUT, 1% of VOUT, Nom
IOUT1=10A, (IOUT2+IOUT3) = 4.2A
F.L. VIN=Nominal
6.0
86
87
VKP100MT515C OUTPUT SPECIFICATIONS
PARAMETER
Output Power
Set Point Voltage
Output Current, IOUT
Output Ripple, p-p
Output Adjust Range
Output Temperature Drift
Line Regulation
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Peak Deviation
Settling Time
Overvoltage Limit
Efficiency
CONDITIONS
Total Combined O/P Power =
100 Watts Max
IO Nom
Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified.
OUTPUT 1
OUTPUT 2
OUTPUT 3
Min
Nom
Max
Min
Nom
Max
Min
Nom
Max
UNITS
50
0.5
DC to 20MHz*
*
5.0
10
100
4.60
.02
100
20
150
5.50
.05
25
0
15.3
1.66
125
.02
50
3.33
0
500
Dependent on V1
.05
25
50
15.3
1.66
125
3.33
500
.02
.05
W
V
A
mV
V
%/°C
VIN, MinbVINbVIN, Max
IO = IO, Nom
Min Load to Rated Load
Other Outputs Min Load
0.05
0.05
26.0
20.0
1.0
1.0
1.0
2.0
See Regulation Curves
26.0
200
300
mV
35
50
7.0
MSec
V
%
5.0
4.0
5.0
1.0
2.0
See Regulation Curves
5.0
4.0
5.0
%
%
A
A
50 to 100% Load Step
VOUT, 1% of VOUT, Nom
IOUT1=10A, (IOUT2+IOUT3) = 4.2A
F.L. VIN=Nominal
6.0
86
87
*See Application Notes available on the web at www.cd4power.com
www.murata-ps.com
Technical enquiries - email: [email protected], tel: +1 508 339 3000
VKP100MTC.B01 Page 3 of 6
VKP100MTC Series
100 Watt, Dual/Triple Output, Half Brick DC/DC Converter
TYPICAL PERFORMANCE CURVE
ABSOLUTE MAXIMUM RATINGS
Output Short-Circuit Duration ..................................... Continuous
Baseplate Temperature .................................................... +100°C
Lead Temperature (soldering, 10 seconds max) .............. +300°C
Storage Temperature ....................................................... +125°C
Input to Output Isolation ............................................... 1500 VDC
www.murata-ps.com
TCASE = +40°C, nominal input voltage, nominal load,
recommended external components applied, unless otherwise specified.
(Refer to Application Note DCAN-9 at www.cd4power.com)
ORDERING INFORMATION
VKP100
MTYZ - L
C
Device Family
Indicates 100 Watt Regulated Unit
Model Number
Selected from Table of Electrical Characteristics
Where:
X = Input Voltage (M = 48VDC)
T = Number of Outputs (Triple "T")
Y = 3 for 3.3V, 5 for 5V
Z = 12 for 12V, 15 for 15V
Lead Length
0.250" - No Number
0.145" - (6)
0.110" - (8)
RoHS Compliant
Technical enquiries - email: [email protected], tel: +1 508 339 3000
VKP100MTC.B01 Page 4 of 6
VKP100MTC Series
100 Watt, Dual/Triple Output, Half Brick DC/DC Converter
TYPICAL PERFORMANCE CURVE
TCASE = +40°C, nominal input voltage, nominal load,
recommended external components applied, unless otherwise specified.
(Refer to Application Note DCAN-9 at www.cd4power.com)
FULL LOAD EFFICIENCY
vs LOAD DISTRIBUTION
EFFICIENCY vs OUTPUT LOAD
90
VIN = MIN.
VIN = NOM.
VIN = MAX.
Output Voltage |(V)|
85
Efficiency (%)
Efficiency (%)
20
VIN = MIN
85
VKP100xT312C
LOAD REGULATION
90
80
VIN = MAX
80
75
75
15
14.0
12.2
11.0
10
5
3.3V
3.0/0.8 6.0/1.7 9.0/2.5 1 2 / 3 . 3
Iout1/(Iout2 + Iout3)(A)
70
0.5/8.4
15/4.2
VIN = MIN.
VIN = NOM.
VIN = MAX.
80
18
85
VIN = MAX
80
75
75
30/0
20
VIN = MIN
Efficiency (%)
85
15/4.2
Iout1/(Iout2 + Iout3)(A)
LOAD REGULATION
90
90
Efficiency (%)
0
0.5/8.4
30/0
FULL LOAD EFFICIENCY
vs LOAD DISTRIBUTION
EFFICIENCY vs OUTPUT LOAD
VKP100xT315C
15/4.2
Iout1/(Iout2 + Iout3)(A)
Output Voltage |(V)|
70
0.50/0
15.9
15
14.5
10
5
3.3V
70
0.5/6.8
15/3.4
VIN = MIN.
VIN = NOM.
VIN = MAX.
Efficiency (%)
Efficiency (%)
2.0/0.8 4.0/1.7 6.0/2.5 8.0/3.3
Iout1/(Iout2 + Iout3)(A)
90
70
0.5/8.4
10/4.2
10/3.4
20/0
20
VIN = MIN
80
70
0.5/6.8
10/4.2
Iout1/(Iout2 + Iout3)(A)
LOAD REGULATION
75
75
12.0
10
0
0.5/8.4
20/0
VIN = MAX
Efficiency (%)
Efficiency (%)
10/4.2
Iout1/(Iout2 + Iout3)(A)
85
80
www.murata-ps.com
13.2
10.5
5.1
90
VIN = MIN.
VIN = NOM.
VIN = MAX.
2.0/0.9 4.0/1.4 6.0/2.0 8.0/2.7
Iout1/(Iout2 + Iout3)(A)
15
FULL LOAD EFFICIENCY
vs LOAD DISTRIBUTION
85
70
0.50/0
VIN = MAX
80
EFFICIENCY vs OUTPUT LOAD
VKP100xT515C
20
75
75
70
0.50/0
30/0
VIN = MIN
85
80
15/3.4
Iout1/(Iout2 + Iout3)(A)
LOAD REGULATION
90
85
VKP100xT512C
0
0.5/6.8
30/0
FULL LOAD EFFICIENCY
vs LOAD DISTRIBUTION
EFFICIENCY vs OUTPUT LOAD
90
15/3.4
Iout1/(Iout2 + Iout3)(A)
Output Voltage |(V)|
3.0/0.7 6.0/1.4 9.0/2.0 12/2.9
Iout1/(Iout2 + Iout3)(A)
Output Voltage |(V)|
70
0.50/0
15
16.7
15.3
13.9
10
5
10/3.4
Iout1/(Iout2 + Iout3)(A)
20/0
0
0.5/6.8
10/3.4
Iout1/(Iout2 + Iout3)(A)
20/0
Technical enquiries - email: [email protected], tel: +1 508 339 3000
VKP100MTC.B01 Page 5 of 6
VKP100MTC Series
100 Watt, Dual/Triple Output, Half Brick DC/DC Converter
MECHANICAL
SIDE VIEW
TOP VIEW
NOTES:
All dimensions are in inches (millimeters).
PIN PLACEMENT TOLERANCE: ± 0.005"
MECHANICAL TOLERANCE: ± 0.015"
Marked with: specific model ordered, date code, job code.
MATERIAL: Units are encapsulated in a low thermal resistance molding
compound which has excellent chemical resistance and electrical properties
in high humidity environments and over a wide operating temperature
range. The encapsulant and outer shell of the unit have UL94V-0 ratings.
Lead material is solder plated to allow ease of solderability.
*See Ordering Information on page 4 for available lead lengths.
PIN CONNECTIONS
1
2
PRIMARY ON/OFF
-VIN
3
4
5
6
7
8
9
10
11
12
+VIN
SYNC IN
-V2
+V2
TRIM
+V1
-V1
SECONDARY ON/OFF
+V3
-V3
USA:
Tucson (Az), Tel: (800) 547 2537, email: [email protected]
Canada: Toronto, Tel: (866) 740 1232, email: [email protected]
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected]
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected]
Germany: München, Tel: +49 (0)89-544334-0, email: [email protected]
www.murata-ps.com email: [email protected] ISO 9001 REGISTERED
Japan:
Tokyo, Tel: 3-3779-1031, email: [email protected]
Osaka, Tel: 6-6354-2025, email: [email protected]
Website: www.murata-ps.jp
China:
Shanghai, Tel: +86 215 027 3678, email: [email protected]
Guangzhou, Tel: +86 208 221 8066, email: [email protected]
07/28/08
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2008 Murata Power Solutions, Inc.
www.murata-ps.com
Technical enquiries - email: [email protected], tel: +1 508 339 3000
VKP100MTC.B01 Page 6 of 6