POWER ANALYZER 3390-10

POWER ANALYZER
3390-10
Power measuring instruments
Maximizing the Efficiency of Energy Conversion
Super Precise ±0.1% Accuracy Model
to Meet the Demanding Needs of Today
Exceed the Accuracy of Direct Wiring
With Pull-Through Current Sensors
Pull-through Current Sensors
Models CT6862-10, CT6863-10 and 9709-10
For 50A, 200A and 500A Testing
2
A Higher-Accuracy Power Meter Supporting the Attainment of Maximum Efficiency
T
he needs of electrical devices driving energy
conservation and green energy initiatives
such as motors, inverters, solar panels, power
conditioners, electric vehicles, and air conditioners
are increasing at a pace never seen before. For
R&D centers wishing for 0.1% levels of efficiency
improvement, highly precise and accurate large
current measurements are now within reach. The
new 3390-10 delivers unsurpassed top-of-the-class
±0.1% accuracy to aid in accomplishing maximum
efficiency in all of your devices.
Improved
Efficiency
POINT
1
Enhanced
Accuracy
Larger
Currents
Pair the 3390-10 with High Accuracy Sensors
And Achieve an Even Higher Level of Excellence in Testing
High Accuracy Version
of Model 3390
High Accuracy Versions of
Pull-through Current Sensors
Enriched Current Sensors Offer Even High Accuracy
Pull-through Current Sensor Pull-through Current Sensor
CT6862-10 50A
CT6863-10 200A
3390-10
CT686x-10 series
9709-10
0.1%
Combined Accuracy of
0.16%
±
Standard 3390
Accuracy
Pull-through Current Sensor
9709-10 500A
Pull-through current sensors deliver accuracy surpassing that
of traditional shunt resistors while remaining resilient against
overheating to enable high current measurements
±
Standard Setup
Power Meter
Accuracy
±0.1%
Current Sensor
Accuracy
Combined
±0.06%
High Accuracy Setup
Defined Combined
Accuracy
All Ranges
Accuracy differs depending on
current range
45 to 66Hz
±0.16%
45 to 66Hz
±0.1%
Refer to specifications for DC accuracy.
Enhanced accuracy parameters available with the higher accuracy combination:
•Voltage Measurement Accuracy: DC (45 to 66 Hz accuracy remains the same as the 3390)
•Current and Active Power Measurement Accuracy: DC and 45 to 66Hz
•Effect of Power Factor: 45 to 66Hz
Accuracy for other parameters is the same as that on the standard Model 3390. Accuracy is guaranteed for 1 year.
Accuracy for the high accuracy Models 3390-10 and Current Sensors are not defined individually. Please use these products in combination to obtain ±0.1% accuracy.
No need to worry about setting the correct range.
POINT
2
±0.1% on ALL Ranges
Switch from one range to another and still maintain the same accuracy.
500A Sensor
500A Range
50A Range
10A Range
High Accuracy Model 3390-10
Accuracy(%)
Accuracy(%)
Standard Model 3390
±0.65%
Accuracy depends
on the range
±0.5
±0.16%
0.0
±0.5
±0.25%
500A
Range
50A
Range
0.0
10A
Range
Accuracy when pairing Model 3390 with
the 9709 AC/DC Current Sensor (500A)
and measuring the f.s. current at each range
Accuracy is
±0.1%
at ANY range
±0.1%
±0.1%
±0.1%
500A
Range
50A
Range
10A
Range
Accuracy when pairing Model 3390-10 with
the 9709-10 AC/DC Current Sensor (500A)
and measuring the f.s. current at each range
(45 to 66Hz)
(45 to 66Hz)
High Accuracy Guarantee Period is Further Extended
POINT
3
Accuracy guaranteed for 1 year
Minimize calibration frequency and maximize work efficiency
Standard Model
3390
3390-10
▼
6 months*
12 months
High Accuracy Model
The following options are also offered
with 1 year guaranteed accuracy:
MOTOR TESTING OPTION 9791
D/A OUTPUT OPTION 9792
MOTOR TESTING & D/A OUTPUT OPTION 9793
*Accuracy for Models 9791, 9792 and 9793 remain the same.
For 1-year guaranteed accuracy on Model 3390, the accuracy
uncertainty must increase 1.5 times the accuracy guaranteed
for 6 months.
3
POINT
on Any Channel
4 Measure
High accuracy using HIOKI high accuracy current sensors is
guaranteed, no matter which channel you use
200A Sensor
500A Sensor
Conditions for Current Input
Guaranteed
Accuracy
Model 3390-10 Specifications
A c c u r a c y Accuracy guaranteed for 1 year
DC
45Hz to 66Hz
0.5Hz to 30Hz
30Hz to 45Hz
66Hz to 1kHz
1kHz to 10kHz
10kHz to 50kHz
50kHz to 100kHz
100kHz to 150kHz
Only when using HIOKI high-accuracy current sensors (options)
(Accuracy specifications defined for Model 3390 apply when
other sensors are used)
Temperature and 23°C±3°C(73°F±5°F), max. 80% rh (3390-10)
Humidity Range 23°C±5°C(73°F±9°F), max. 80% rh (when using
the 50A to 500A range of Model 9709-10)
±1°C(1.8°F) of temperature after zero adjustment,
within 23°C±5°C(73°F±9°F), max. 80% rh (when
using the 10A and 20A range of Model 9709-10)
0 to 40°C(32°F to 104°F), max. 80% rh (when using
Model CT6862-10 or CT6863-10)
Warm-up time At least 30 minutes
Voltage(U)
Current(I)
Active Power(P)
±0.07%rdg.±0.1%f.s. ±0.07%rdg.±0.1%f.s. ±0.07%rdg.±0.1%f.s.
±0.05%rdg.±0.05%f.s. ±0.05%rdg.±0.05%f.s. ±0.05%rdg.±0.05%f.s.
Accuracy is defined for the frequency range indicated above only when pairing
Model 3390-10 with HIOKI high accuracy current sensors (where f.s. is based on
the ranges of the 3390-10).
Voltage and active power values for 1000V or higher measurements are for
reference only.
Voltage(U)
Current(I)
Active Power(P)
±0.1%rdg.±0.2%f.s.
±0.1%rdg.±0.2%f.s.
±0.1%rdg.±0.2%f.s.
±0.1%rdg.±0.1%f.s.
±0.1%rdg.±0.1%f.s.
±0.1%rdg.±0.1%f.s.
±0.1%rdg.±0.1%f.s.
±0.1%rdg.±0.1%f.s.
±0.1%rdg.±0.1%f.s.
±0.2%rdg.±0.1%f.s.
±0.2%rdg.±0.1%f.s.
±0.2%rdg.±0.1%f.s.
±0.3%rdg.±0.2%f.s.
±0.3%rdg.±0.2%f.s.
±0.4%rdg.±0.3%f.s.
±1.0%rdg.±0.3%f.s.
±1.0%rdg.±0.3%f.s.
±1.5%rdg.±0.5%f.s.
±20%f.s.
±20%f.s.
±20%f.s.
Input
Temperature
coefficient
For current and active power accuracy within the frequency range indicated above,
add the uncertainty range of the current sensors.
The following accuracy data are for reference only:
Voltage, current and active power within the 0.5Hz to 10Hz frequency range
Voltage and active power exceeding 220V within the 10Hz to 10Hz frequency range
Effect of
Voltage and active power exceeding 750V within the 30kHz to 100kHz frequency range
Voltage and active power exceeding (22000/f[kHz])V within the 100kHz to 150kHz frequency range Power Factor
Voltage and active power exceeding 1000V
On condition that the signal is a sine wave, with
power factor=1, voltage to ground=0V, after zeroadjustment is conducted with current sensors at
23°C±3°C(73°F±5°F), and when the fundamental
waveform is the sync source
When used within the operating temperature range but outside the guaranteed
temperature and humidity ranges for accuracy, add the following (the f.s. of
the ranges of Model 3390-10 applies)
3390-10
±0.01%f.s./°C; for DC, add ±0.01%f.s./°C
9709-10
Current: ±0.01%rdg./°C; for DC, add ±(0.005%f.
s.+2mA)/°C
Active power: ±0.01%rdg./°C; for DC, add ±(displayed
voltage value x (0.005%f.s.+2mA))/°C
CT6862-10,
Current: ±0.01%rdg./°C; for DC, add ±0.005%f.s. /°C
CT6863-10
Active Power: ±0.01
Maximum ±0.2%f.s. (at 45Hz to 66Hz, p.f.=0.0)
Add ±0.45%f.s. when LPF is 500 Hz
For specifications not defined above, please refer to the catalog for Model 3390 Power Analyzer.
Power Analyzer (High Accuracy Model) 3390-10
Dedicated Current Sensors (High Accuracy Models)
AC/DC CURRENT SENSOR(50A)
CT6862-10
AC/DC CURRENT SENSOR(200A)
CT6863-10
AC/DC CURRENT SENSOR(500A)
9709-10
Supplied Accessories: Instruction Manual for Model 3390 x 1, Instruction Manual
for Model 3390-10 x 1, Measurement Guide x 1, Power cord x 1, USB cable x 1,
D-sub connector x 1 (when 9792 or 9793 is installed), Color label x 2
Please note: The dedicated PC application software and communication
command manual for Model 3390 are also compatible to Model 3390-10. Please
download them from the HIOKI website.
Please purchase separately-sold voltage cords and current sensors for measurements.
A HIOKI-issued PC card is also necessary in order to save measured data.
If calibration data sheets pairing the 3390-10 with specific current sensors
are required, please specify at time of order. Calibration data sheets for
specific combinations after the products have been delivered will require
that the devices be returned to the HIOKI factory for re-calibration.
Please also specify preferred channels if necessary.
Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
Headquarters :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
http://www.hioki.co.jp / E-mail: [email protected]
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
http://www.hiokiusa.com / E-mail: [email protected]
1608-1610,Shanghai Times Square Office, 93 Huai Hai Zhong Road
Shanghai, P.R.China POSTCODE: 200021
TEL +86-21-63910090/63910092 FAX +86-21-63910360
http://www.hioki.cn / E-mail: [email protected]
Beijing Office : TEL +86-10-84418761 / 84418762
Guangzhou Office : TEL +86-20-38392673 / 38392676
DISTRIBUTED BY
HIOKI INDIA PRIVATE LIMITED :
Khandela House, 24 Gulmohar Colony Indore 452 018 (M.P.), India
TEL +91-731-4223901, 4223902 FAX +91-731-4223903
http://www.hioki.in / E-mail: [email protected]
HIOKI SINGAPORE PTE. LTD. :
33 Ubi Avenue 3, #03-02 Vertex, Singapore 408868
TEL +65-6634-7677 FAX +65-6634-7477
E-mail: [email protected]
All information correct as of June. 17, 2011. All specifications are subject to change without notice.
3390-10E1-16M-03K
Printed in Japan